Measurement and Evaluation of Quantitative Performance of PET/CT Images before a Multicenter Clinical Trial

To ensure the reliability of the planned multi-center clinical trial, we assessed the consistence and comparability of the quantitative parameters of the eight PET/CT units that will be used in this trial. PET/CT images were scanned using a PET NEMA image quality phantom (Biodex) on the eight units...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhu, Yanjia, Geng, Caizheng, Huang, Jia, Liu, Juzhen, Wu, Ning, Xin, Jun, Xu, Hao, Yu, Lijuan, Geng, Jianhua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5997997/
https://www.ncbi.nlm.nih.gov/pubmed/29899470
http://dx.doi.org/10.1038/s41598-018-27143-4
_version_ 1783331162502987776
author Zhu, Yanjia
Geng, Caizheng
Huang, Jia
Liu, Juzhen
Wu, Ning
Xin, Jun
Xu, Hao
Yu, Lijuan
Geng, Jianhua
author_facet Zhu, Yanjia
Geng, Caizheng
Huang, Jia
Liu, Juzhen
Wu, Ning
Xin, Jun
Xu, Hao
Yu, Lijuan
Geng, Jianhua
author_sort Zhu, Yanjia
collection PubMed
description To ensure the reliability of the planned multi-center clinical trial, we assessed the consistence and comparability of the quantitative parameters of the eight PET/CT units that will be used in this trial. PET/CT images were scanned using a PET NEMA image quality phantom (Biodex) on the eight units of Discovery PET/CT 690 from GE Healthcare. The scanning parameters were the same with the ones to be used in the planned trial. The (18)F-NaF concentration in the background was 5.3 kBq/ml, while the ones in the spheres of diameter 37 mm, 22 mm, 17 mm and 10 mm were 8:1 as to that of the background and the ones in the spheres of diameter 28 mm and 13 mm were 0 kBq/ml. The consistency of hot sphere recovery coefficient (HRC), cold sphere recovery coefficient (CRC), hot sphere contrast (Q(H)) and cold sphere contrast (Q(c)) among these 8 PET/CTs was analyzed. The variation of the main quantitative parameters of the eight PET/CT systems was within 10%, which is acceptable for the clinical trial.
format Online
Article
Text
id pubmed-5997997
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-59979972018-06-21 Measurement and Evaluation of Quantitative Performance of PET/CT Images before a Multicenter Clinical Trial Zhu, Yanjia Geng, Caizheng Huang, Jia Liu, Juzhen Wu, Ning Xin, Jun Xu, Hao Yu, Lijuan Geng, Jianhua Sci Rep Article To ensure the reliability of the planned multi-center clinical trial, we assessed the consistence and comparability of the quantitative parameters of the eight PET/CT units that will be used in this trial. PET/CT images were scanned using a PET NEMA image quality phantom (Biodex) on the eight units of Discovery PET/CT 690 from GE Healthcare. The scanning parameters were the same with the ones to be used in the planned trial. The (18)F-NaF concentration in the background was 5.3 kBq/ml, while the ones in the spheres of diameter 37 mm, 22 mm, 17 mm and 10 mm were 8:1 as to that of the background and the ones in the spheres of diameter 28 mm and 13 mm were 0 kBq/ml. The consistency of hot sphere recovery coefficient (HRC), cold sphere recovery coefficient (CRC), hot sphere contrast (Q(H)) and cold sphere contrast (Q(c)) among these 8 PET/CTs was analyzed. The variation of the main quantitative parameters of the eight PET/CT systems was within 10%, which is acceptable for the clinical trial. Nature Publishing Group UK 2018-06-13 /pmc/articles/PMC5997997/ /pubmed/29899470 http://dx.doi.org/10.1038/s41598-018-27143-4 Text en © The Author(s) 2018 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Zhu, Yanjia
Geng, Caizheng
Huang, Jia
Liu, Juzhen
Wu, Ning
Xin, Jun
Xu, Hao
Yu, Lijuan
Geng, Jianhua
Measurement and Evaluation of Quantitative Performance of PET/CT Images before a Multicenter Clinical Trial
title Measurement and Evaluation of Quantitative Performance of PET/CT Images before a Multicenter Clinical Trial
title_full Measurement and Evaluation of Quantitative Performance of PET/CT Images before a Multicenter Clinical Trial
title_fullStr Measurement and Evaluation of Quantitative Performance of PET/CT Images before a Multicenter Clinical Trial
title_full_unstemmed Measurement and Evaluation of Quantitative Performance of PET/CT Images before a Multicenter Clinical Trial
title_short Measurement and Evaluation of Quantitative Performance of PET/CT Images before a Multicenter Clinical Trial
title_sort measurement and evaluation of quantitative performance of pet/ct images before a multicenter clinical trial
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5997997/
https://www.ncbi.nlm.nih.gov/pubmed/29899470
http://dx.doi.org/10.1038/s41598-018-27143-4
work_keys_str_mv AT zhuyanjia measurementandevaluationofquantitativeperformanceofpetctimagesbeforeamulticenterclinicaltrial
AT gengcaizheng measurementandevaluationofquantitativeperformanceofpetctimagesbeforeamulticenterclinicaltrial
AT huangjia measurementandevaluationofquantitativeperformanceofpetctimagesbeforeamulticenterclinicaltrial
AT liujuzhen measurementandevaluationofquantitativeperformanceofpetctimagesbeforeamulticenterclinicaltrial
AT wuning measurementandevaluationofquantitativeperformanceofpetctimagesbeforeamulticenterclinicaltrial
AT xinjun measurementandevaluationofquantitativeperformanceofpetctimagesbeforeamulticenterclinicaltrial
AT xuhao measurementandevaluationofquantitativeperformanceofpetctimagesbeforeamulticenterclinicaltrial
AT yulijuan measurementandevaluationofquantitativeperformanceofpetctimagesbeforeamulticenterclinicaltrial
AT gengjianhua measurementandevaluationofquantitativeperformanceofpetctimagesbeforeamulticenterclinicaltrial