Cargando…
Measurement and Evaluation of Quantitative Performance of PET/CT Images before a Multicenter Clinical Trial
To ensure the reliability of the planned multi-center clinical trial, we assessed the consistence and comparability of the quantitative parameters of the eight PET/CT units that will be used in this trial. PET/CT images were scanned using a PET NEMA image quality phantom (Biodex) on the eight units...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5997997/ https://www.ncbi.nlm.nih.gov/pubmed/29899470 http://dx.doi.org/10.1038/s41598-018-27143-4 |
_version_ | 1783331162502987776 |
---|---|
author | Zhu, Yanjia Geng, Caizheng Huang, Jia Liu, Juzhen Wu, Ning Xin, Jun Xu, Hao Yu, Lijuan Geng, Jianhua |
author_facet | Zhu, Yanjia Geng, Caizheng Huang, Jia Liu, Juzhen Wu, Ning Xin, Jun Xu, Hao Yu, Lijuan Geng, Jianhua |
author_sort | Zhu, Yanjia |
collection | PubMed |
description | To ensure the reliability of the planned multi-center clinical trial, we assessed the consistence and comparability of the quantitative parameters of the eight PET/CT units that will be used in this trial. PET/CT images were scanned using a PET NEMA image quality phantom (Biodex) on the eight units of Discovery PET/CT 690 from GE Healthcare. The scanning parameters were the same with the ones to be used in the planned trial. The (18)F-NaF concentration in the background was 5.3 kBq/ml, while the ones in the spheres of diameter 37 mm, 22 mm, 17 mm and 10 mm were 8:1 as to that of the background and the ones in the spheres of diameter 28 mm and 13 mm were 0 kBq/ml. The consistency of hot sphere recovery coefficient (HRC), cold sphere recovery coefficient (CRC), hot sphere contrast (Q(H)) and cold sphere contrast (Q(c)) among these 8 PET/CTs was analyzed. The variation of the main quantitative parameters of the eight PET/CT systems was within 10%, which is acceptable for the clinical trial. |
format | Online Article Text |
id | pubmed-5997997 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-59979972018-06-21 Measurement and Evaluation of Quantitative Performance of PET/CT Images before a Multicenter Clinical Trial Zhu, Yanjia Geng, Caizheng Huang, Jia Liu, Juzhen Wu, Ning Xin, Jun Xu, Hao Yu, Lijuan Geng, Jianhua Sci Rep Article To ensure the reliability of the planned multi-center clinical trial, we assessed the consistence and comparability of the quantitative parameters of the eight PET/CT units that will be used in this trial. PET/CT images were scanned using a PET NEMA image quality phantom (Biodex) on the eight units of Discovery PET/CT 690 from GE Healthcare. The scanning parameters were the same with the ones to be used in the planned trial. The (18)F-NaF concentration in the background was 5.3 kBq/ml, while the ones in the spheres of diameter 37 mm, 22 mm, 17 mm and 10 mm were 8:1 as to that of the background and the ones in the spheres of diameter 28 mm and 13 mm were 0 kBq/ml. The consistency of hot sphere recovery coefficient (HRC), cold sphere recovery coefficient (CRC), hot sphere contrast (Q(H)) and cold sphere contrast (Q(c)) among these 8 PET/CTs was analyzed. The variation of the main quantitative parameters of the eight PET/CT systems was within 10%, which is acceptable for the clinical trial. Nature Publishing Group UK 2018-06-13 /pmc/articles/PMC5997997/ /pubmed/29899470 http://dx.doi.org/10.1038/s41598-018-27143-4 Text en © The Author(s) 2018 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Zhu, Yanjia Geng, Caizheng Huang, Jia Liu, Juzhen Wu, Ning Xin, Jun Xu, Hao Yu, Lijuan Geng, Jianhua Measurement and Evaluation of Quantitative Performance of PET/CT Images before a Multicenter Clinical Trial |
title | Measurement and Evaluation of Quantitative Performance of PET/CT Images before a Multicenter Clinical Trial |
title_full | Measurement and Evaluation of Quantitative Performance of PET/CT Images before a Multicenter Clinical Trial |
title_fullStr | Measurement and Evaluation of Quantitative Performance of PET/CT Images before a Multicenter Clinical Trial |
title_full_unstemmed | Measurement and Evaluation of Quantitative Performance of PET/CT Images before a Multicenter Clinical Trial |
title_short | Measurement and Evaluation of Quantitative Performance of PET/CT Images before a Multicenter Clinical Trial |
title_sort | measurement and evaluation of quantitative performance of pet/ct images before a multicenter clinical trial |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5997997/ https://www.ncbi.nlm.nih.gov/pubmed/29899470 http://dx.doi.org/10.1038/s41598-018-27143-4 |
work_keys_str_mv | AT zhuyanjia measurementandevaluationofquantitativeperformanceofpetctimagesbeforeamulticenterclinicaltrial AT gengcaizheng measurementandevaluationofquantitativeperformanceofpetctimagesbeforeamulticenterclinicaltrial AT huangjia measurementandevaluationofquantitativeperformanceofpetctimagesbeforeamulticenterclinicaltrial AT liujuzhen measurementandevaluationofquantitativeperformanceofpetctimagesbeforeamulticenterclinicaltrial AT wuning measurementandevaluationofquantitativeperformanceofpetctimagesbeforeamulticenterclinicaltrial AT xinjun measurementandevaluationofquantitativeperformanceofpetctimagesbeforeamulticenterclinicaltrial AT xuhao measurementandevaluationofquantitativeperformanceofpetctimagesbeforeamulticenterclinicaltrial AT yulijuan measurementandevaluationofquantitativeperformanceofpetctimagesbeforeamulticenterclinicaltrial AT gengjianhua measurementandevaluationofquantitativeperformanceofpetctimagesbeforeamulticenterclinicaltrial |