Cargando…

Standardized programming to reduce the burden of inappropriate therapies in implantable cardioverter defibrillators - Single centre follow up results

BACKGROUND: Current algorithms and device morphology templates have been proposed in current Implantable Cardioverter-Defibrillators (ICDs) to minimize inappropriate therapies (ITS), but this has not been completely successful. AIM: Assess the impact of a deliberate strategy of using an atrial lead...

Descripción completa

Detalles Bibliográficos
Autores principales: Boles, U., Gul, E.E., Fitzgerald, L., Sadiq Ali, F., Nolan, C., Aldworth-Gaumond, K., Redfearn, D.R., Baranchuk, A., Glover, B., Simpson, C., Abdollah, H., Michael, K.A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5998837/
https://www.ncbi.nlm.nih.gov/pubmed/29111168
http://dx.doi.org/10.1016/j.ipej.2017.10.010
Descripción
Sumario:BACKGROUND: Current algorithms and device morphology templates have been proposed in current Implantable Cardioverter-Defibrillators (ICDs) to minimize inappropriate therapies (ITS), but this has not been completely successful. AIM: Assess the impact of a deliberate strategy of using an atrial lead implant with standardized parameters; based on all current ICD discriminators and technologies, on the burden of ITS. METHOD: A retrospective single-centre analysis of 250 patients with either dual chamber (DR) ICDs or biventricular ICDs (CRTDs) over a (41.9 ± 27.3) month period was performed. The incidence of ITS on all ICD and CRTD patients was chronicled after the implementation of standardized programming. RESULTS: 39 events of anti-tachycardial pacing (ATP) and/or shocks were identified in 20 patients (8% incidence rate among patients). The total number of individual therapies was 120, of which 34% were inappropriate ATP, and 36% were inappropriate shocks. 11 patients of the 250 patients received ITS (4.4%). Of the 20 patients, four had ICDs for primary prevention and 16 for a secondary prevention. All the episodes in the primary indication group were inappropriate, while seven patients (43%) of the secondary indication group experienced inappropriate therapies. CONCLUSIONS: The burden of ITS in the population of patients receiving ICDs was 4.4% in the presence of atrial leads. The proposed rationalized programming criteria seems an effective strategy to minimize the burden of inappropriate therapies and will require further validation.