Cargando…

Implications for high-precision dose radiation therapy planning or limited surgical resection after percutaneous computed tomography-guided lung nodule biopsy using a tract sealant

PURPOSE: Precision radiation therapy such as stereotactic body radiation therapy and limited resection are being used more frequently to treat intrathoracic malignancies. Effective local control requires precise radiation target delineation or complete resection. Lung biopsy tracts (LBT) on computed...

Descripción completa

Detalles Bibliográficos
Autores principales: de Groot, Patricia M., Shroff, Girish S., Ahrar, Judy, Sabloff, Bradley S., Gladish, Garret M., Moran, Cesar, Gupta, Sanjay, Gladish, Gregory W., Chang, Joe Y., Erasmus, Jeremy J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6000068/
https://www.ncbi.nlm.nih.gov/pubmed/29904738
http://dx.doi.org/10.1016/j.adro.2017.12.005
_version_ 1783331607379181568
author de Groot, Patricia M.
Shroff, Girish S.
Ahrar, Judy
Sabloff, Bradley S.
Gladish, Garret M.
Moran, Cesar
Gupta, Sanjay
Gladish, Gregory W.
Chang, Joe Y.
Erasmus, Jeremy J.
author_facet de Groot, Patricia M.
Shroff, Girish S.
Ahrar, Judy
Sabloff, Bradley S.
Gladish, Garret M.
Moran, Cesar
Gupta, Sanjay
Gladish, Gregory W.
Chang, Joe Y.
Erasmus, Jeremy J.
author_sort de Groot, Patricia M.
collection PubMed
description PURPOSE: Precision radiation therapy such as stereotactic body radiation therapy and limited resection are being used more frequently to treat intrathoracic malignancies. Effective local control requires precise radiation target delineation or complete resection. Lung biopsy tracts (LBT) on computed tomography (CT) scans after the use of tract sealants can mimic malignant tract seeding (MTS) and it is unclear whether these LBTs should be included in the calculated tumor volume or resected. This study evaluates the incidence, appearance, evolution, and malignant seeding of LBTs. METHODS AND MATERIALS: A total of 406 lung biopsies were performed in oncology patients using a tract sealant over 19 months. Of these patients, 326 had follow-up CT scans and were included in the study group. Four thoracic radiologists retrospectively analyzed the imaging, and a pathologist examined 10 resected LBTs. RESULTS: A total of 234 of 326 biopsies (72%, including primary lung cancer [n = 98]; metastases [n = 81]; benign [n = 50]; and nondiagnostic [n = 5]) showed an LBT on CT. LBTs were identified on imaging 0 to 3 months after biopsy. LBTs were typically straight or serpiginous with a thickness of 2 to 5 mm. Most LBTs were unchanged (92%) or decreased (6.3%) over time. An increase in LBT thickness/nodularity that was suspicious for MTS occurred in 4 of 234 biopsies (1.7%). MTS only occurred after biopsy of metastases from extrathoracic malignancies, and none occurred in patients with lung cancer. CONCLUSIONS: LBTs are common on CT after lung biopsy using a tract sealant. MTS is uncommon and only occurred in patients with extrathoracic malignancies. No MTS was found in patients with primary lung cancer. Accordingly, potential alteration in planned therapy should be considered only in patients with LBTs and extrathoracic malignancies being considered for stereotactic body radiation therapy or wedge resection.
format Online
Article
Text
id pubmed-6000068
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-60000682018-06-14 Implications for high-precision dose radiation therapy planning or limited surgical resection after percutaneous computed tomography-guided lung nodule biopsy using a tract sealant de Groot, Patricia M. Shroff, Girish S. Ahrar, Judy Sabloff, Bradley S. Gladish, Garret M. Moran, Cesar Gupta, Sanjay Gladish, Gregory W. Chang, Joe Y. Erasmus, Jeremy J. Adv Radiat Oncol Lung Cancer PURPOSE: Precision radiation therapy such as stereotactic body radiation therapy and limited resection are being used more frequently to treat intrathoracic malignancies. Effective local control requires precise radiation target delineation or complete resection. Lung biopsy tracts (LBT) on computed tomography (CT) scans after the use of tract sealants can mimic malignant tract seeding (MTS) and it is unclear whether these LBTs should be included in the calculated tumor volume or resected. This study evaluates the incidence, appearance, evolution, and malignant seeding of LBTs. METHODS AND MATERIALS: A total of 406 lung biopsies were performed in oncology patients using a tract sealant over 19 months. Of these patients, 326 had follow-up CT scans and were included in the study group. Four thoracic radiologists retrospectively analyzed the imaging, and a pathologist examined 10 resected LBTs. RESULTS: A total of 234 of 326 biopsies (72%, including primary lung cancer [n = 98]; metastases [n = 81]; benign [n = 50]; and nondiagnostic [n = 5]) showed an LBT on CT. LBTs were identified on imaging 0 to 3 months after biopsy. LBTs were typically straight or serpiginous with a thickness of 2 to 5 mm. Most LBTs were unchanged (92%) or decreased (6.3%) over time. An increase in LBT thickness/nodularity that was suspicious for MTS occurred in 4 of 234 biopsies (1.7%). MTS only occurred after biopsy of metastases from extrathoracic malignancies, and none occurred in patients with lung cancer. CONCLUSIONS: LBTs are common on CT after lung biopsy using a tract sealant. MTS is uncommon and only occurred in patients with extrathoracic malignancies. No MTS was found in patients with primary lung cancer. Accordingly, potential alteration in planned therapy should be considered only in patients with LBTs and extrathoracic malignancies being considered for stereotactic body radiation therapy or wedge resection. Elsevier 2017-12-20 /pmc/articles/PMC6000068/ /pubmed/29904738 http://dx.doi.org/10.1016/j.adro.2017.12.005 Text en © 2017 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Lung Cancer
de Groot, Patricia M.
Shroff, Girish S.
Ahrar, Judy
Sabloff, Bradley S.
Gladish, Garret M.
Moran, Cesar
Gupta, Sanjay
Gladish, Gregory W.
Chang, Joe Y.
Erasmus, Jeremy J.
Implications for high-precision dose radiation therapy planning or limited surgical resection after percutaneous computed tomography-guided lung nodule biopsy using a tract sealant
title Implications for high-precision dose radiation therapy planning or limited surgical resection after percutaneous computed tomography-guided lung nodule biopsy using a tract sealant
title_full Implications for high-precision dose radiation therapy planning or limited surgical resection after percutaneous computed tomography-guided lung nodule biopsy using a tract sealant
title_fullStr Implications for high-precision dose radiation therapy planning or limited surgical resection after percutaneous computed tomography-guided lung nodule biopsy using a tract sealant
title_full_unstemmed Implications for high-precision dose radiation therapy planning or limited surgical resection after percutaneous computed tomography-guided lung nodule biopsy using a tract sealant
title_short Implications for high-precision dose radiation therapy planning or limited surgical resection after percutaneous computed tomography-guided lung nodule biopsy using a tract sealant
title_sort implications for high-precision dose radiation therapy planning or limited surgical resection after percutaneous computed tomography-guided lung nodule biopsy using a tract sealant
topic Lung Cancer
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6000068/
https://www.ncbi.nlm.nih.gov/pubmed/29904738
http://dx.doi.org/10.1016/j.adro.2017.12.005
work_keys_str_mv AT degrootpatriciam implicationsforhighprecisiondoseradiationtherapyplanningorlimitedsurgicalresectionafterpercutaneouscomputedtomographyguidedlungnodulebiopsyusingatractsealant
AT shroffgirishs implicationsforhighprecisiondoseradiationtherapyplanningorlimitedsurgicalresectionafterpercutaneouscomputedtomographyguidedlungnodulebiopsyusingatractsealant
AT ahrarjudy implicationsforhighprecisiondoseradiationtherapyplanningorlimitedsurgicalresectionafterpercutaneouscomputedtomographyguidedlungnodulebiopsyusingatractsealant
AT sabloffbradleys implicationsforhighprecisiondoseradiationtherapyplanningorlimitedsurgicalresectionafterpercutaneouscomputedtomographyguidedlungnodulebiopsyusingatractsealant
AT gladishgarretm implicationsforhighprecisiondoseradiationtherapyplanningorlimitedsurgicalresectionafterpercutaneouscomputedtomographyguidedlungnodulebiopsyusingatractsealant
AT morancesar implicationsforhighprecisiondoseradiationtherapyplanningorlimitedsurgicalresectionafterpercutaneouscomputedtomographyguidedlungnodulebiopsyusingatractsealant
AT guptasanjay implicationsforhighprecisiondoseradiationtherapyplanningorlimitedsurgicalresectionafterpercutaneouscomputedtomographyguidedlungnodulebiopsyusingatractsealant
AT gladishgregoryw implicationsforhighprecisiondoseradiationtherapyplanningorlimitedsurgicalresectionafterpercutaneouscomputedtomographyguidedlungnodulebiopsyusingatractsealant
AT changjoey implicationsforhighprecisiondoseradiationtherapyplanningorlimitedsurgicalresectionafterpercutaneouscomputedtomographyguidedlungnodulebiopsyusingatractsealant
AT erasmusjeremyj implicationsforhighprecisiondoseradiationtherapyplanningorlimitedsurgicalresectionafterpercutaneouscomputedtomographyguidedlungnodulebiopsyusingatractsealant