Cargando…
Maternal cardiovascular hemodynamics in normotensive versus preeclamptic pregnancies: a prospective longitudinal study using a noninvasive cardiac system (NICaS™)
BACKGROUND: Preeclampsia is among the most common medical complications of pregnancy. The clinical utility of invasive hemodynamic monitoring in preeclampsia (e.g., Swan-Ganz catheter) is controversial. Thoracic impedance cardiography (TIC) and Doppler echocardiography are noninvasive techniques but...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6001131/ https://www.ncbi.nlm.nih.gov/pubmed/29898711 http://dx.doi.org/10.1186/s12884-018-1861-7 |
_version_ | 1783331924014530560 |
---|---|
author | Lavie, Anat Ram, Maya Lev, Shaul Blecher, Yair Amikam, Uri Shulman, Yael Avnon, Tomer Weiner, Eran Many, Ariel |
author_facet | Lavie, Anat Ram, Maya Lev, Shaul Blecher, Yair Amikam, Uri Shulman, Yael Avnon, Tomer Weiner, Eran Many, Ariel |
author_sort | Lavie, Anat |
collection | PubMed |
description | BACKGROUND: Preeclampsia is among the most common medical complications of pregnancy. The clinical utility of invasive hemodynamic monitoring in preeclampsia (e.g., Swan-Ganz catheter) is controversial. Thoracic impedance cardiography (TIC) and Doppler echocardiography are noninvasive techniques but they both have important limitations. NICaS™ (NI Medical, PetachTikva, Israel) is a noninvasive cardiac system for determining cardiac output (CO) that utilizes regional impedance cardiography (RIC) by noninvasively measuring the impedance signal in the periphery. It outperformed any other impedance cardiographic technology and was twice as accurate as TIC. METHODS: We used the NICaS™ system to compare the hemodynamic parameters of women with severe preeclampsia (PET group, n = 17) to a cohort of healthy normotensive pregnant women with a singleton pregnancy at term (control group, n = 62) (1/2015–6/2015). Heart rate (HR), stroke volume (SV), CO, total peripheral resistance (TPR) and mean arterial pressure (MAP) were measured 15–30 min before CS initiation, immediately after administering spinal anesthesia, immediately after delivery of the fetus and placenta, at the abdominal fascia closure and within 24–36 and 48–72 h postpartum. RESULTS: The COs before and during the CS were significantly higher in the control group compared to the PET group (P < .05), but reached equivalent values within 24–36 h postpartum. CO peaked at delivery of the newborn and the placenta and started to decline afterwards in both groups. The MAP and TPR values were significantly higher in the PET group at all points of assessment except at 48–72 h postpartum when it was still significantly higher for MAP while the TPR only exhibited a higher trend but not statistically significant. The NICaS™ device noninvasively demonstrated low CO and high TPR profiles in the PET group compared to controls. CONCLUSIONS: The immediate postpartum period is accompanied by the most dramatic hemodynamic changes and fluid shifts, during which the parturient should be closely monitored. The NICaS™ device may help the clinician to customize the most optimal management for individual parturients. Our findings require validation by further studies on larger samples. |
format | Online Article Text |
id | pubmed-6001131 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-60011312018-06-26 Maternal cardiovascular hemodynamics in normotensive versus preeclamptic pregnancies: a prospective longitudinal study using a noninvasive cardiac system (NICaS™) Lavie, Anat Ram, Maya Lev, Shaul Blecher, Yair Amikam, Uri Shulman, Yael Avnon, Tomer Weiner, Eran Many, Ariel BMC Pregnancy Childbirth Research Article BACKGROUND: Preeclampsia is among the most common medical complications of pregnancy. The clinical utility of invasive hemodynamic monitoring in preeclampsia (e.g., Swan-Ganz catheter) is controversial. Thoracic impedance cardiography (TIC) and Doppler echocardiography are noninvasive techniques but they both have important limitations. NICaS™ (NI Medical, PetachTikva, Israel) is a noninvasive cardiac system for determining cardiac output (CO) that utilizes regional impedance cardiography (RIC) by noninvasively measuring the impedance signal in the periphery. It outperformed any other impedance cardiographic technology and was twice as accurate as TIC. METHODS: We used the NICaS™ system to compare the hemodynamic parameters of women with severe preeclampsia (PET group, n = 17) to a cohort of healthy normotensive pregnant women with a singleton pregnancy at term (control group, n = 62) (1/2015–6/2015). Heart rate (HR), stroke volume (SV), CO, total peripheral resistance (TPR) and mean arterial pressure (MAP) were measured 15–30 min before CS initiation, immediately after administering spinal anesthesia, immediately after delivery of the fetus and placenta, at the abdominal fascia closure and within 24–36 and 48–72 h postpartum. RESULTS: The COs before and during the CS were significantly higher in the control group compared to the PET group (P < .05), but reached equivalent values within 24–36 h postpartum. CO peaked at delivery of the newborn and the placenta and started to decline afterwards in both groups. The MAP and TPR values were significantly higher in the PET group at all points of assessment except at 48–72 h postpartum when it was still significantly higher for MAP while the TPR only exhibited a higher trend but not statistically significant. The NICaS™ device noninvasively demonstrated low CO and high TPR profiles in the PET group compared to controls. CONCLUSIONS: The immediate postpartum period is accompanied by the most dramatic hemodynamic changes and fluid shifts, during which the parturient should be closely monitored. The NICaS™ device may help the clinician to customize the most optimal management for individual parturients. Our findings require validation by further studies on larger samples. BioMed Central 2018-06-14 /pmc/articles/PMC6001131/ /pubmed/29898711 http://dx.doi.org/10.1186/s12884-018-1861-7 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Lavie, Anat Ram, Maya Lev, Shaul Blecher, Yair Amikam, Uri Shulman, Yael Avnon, Tomer Weiner, Eran Many, Ariel Maternal cardiovascular hemodynamics in normotensive versus preeclamptic pregnancies: a prospective longitudinal study using a noninvasive cardiac system (NICaS™) |
title | Maternal cardiovascular hemodynamics in normotensive versus preeclamptic pregnancies: a prospective longitudinal study using a noninvasive cardiac system (NICaS™) |
title_full | Maternal cardiovascular hemodynamics in normotensive versus preeclamptic pregnancies: a prospective longitudinal study using a noninvasive cardiac system (NICaS™) |
title_fullStr | Maternal cardiovascular hemodynamics in normotensive versus preeclamptic pregnancies: a prospective longitudinal study using a noninvasive cardiac system (NICaS™) |
title_full_unstemmed | Maternal cardiovascular hemodynamics in normotensive versus preeclamptic pregnancies: a prospective longitudinal study using a noninvasive cardiac system (NICaS™) |
title_short | Maternal cardiovascular hemodynamics in normotensive versus preeclamptic pregnancies: a prospective longitudinal study using a noninvasive cardiac system (NICaS™) |
title_sort | maternal cardiovascular hemodynamics in normotensive versus preeclamptic pregnancies: a prospective longitudinal study using a noninvasive cardiac system (nicas™) |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6001131/ https://www.ncbi.nlm.nih.gov/pubmed/29898711 http://dx.doi.org/10.1186/s12884-018-1861-7 |
work_keys_str_mv | AT lavieanat maternalcardiovascularhemodynamicsinnormotensiveversuspreeclampticpregnanciesaprospectivelongitudinalstudyusinganoninvasivecardiacsystemnicas AT rammaya maternalcardiovascularhemodynamicsinnormotensiveversuspreeclampticpregnanciesaprospectivelongitudinalstudyusinganoninvasivecardiacsystemnicas AT levshaul maternalcardiovascularhemodynamicsinnormotensiveversuspreeclampticpregnanciesaprospectivelongitudinalstudyusinganoninvasivecardiacsystemnicas AT blecheryair maternalcardiovascularhemodynamicsinnormotensiveversuspreeclampticpregnanciesaprospectivelongitudinalstudyusinganoninvasivecardiacsystemnicas AT amikamuri maternalcardiovascularhemodynamicsinnormotensiveversuspreeclampticpregnanciesaprospectivelongitudinalstudyusinganoninvasivecardiacsystemnicas AT shulmanyael maternalcardiovascularhemodynamicsinnormotensiveversuspreeclampticpregnanciesaprospectivelongitudinalstudyusinganoninvasivecardiacsystemnicas AT avnontomer maternalcardiovascularhemodynamicsinnormotensiveversuspreeclampticpregnanciesaprospectivelongitudinalstudyusinganoninvasivecardiacsystemnicas AT weinereran maternalcardiovascularhemodynamicsinnormotensiveversuspreeclampticpregnanciesaprospectivelongitudinalstudyusinganoninvasivecardiacsystemnicas AT manyariel maternalcardiovascularhemodynamicsinnormotensiveversuspreeclampticpregnanciesaprospectivelongitudinalstudyusinganoninvasivecardiacsystemnicas |