Cargando…

Chip-scale high Q-factor glassblown microspherical shells for magnetic sensing

A whispering gallery mode resonator based magnetometer using chip-scale glass microspherical shells is described. A neodynium micro-magnet is elastically coupled and integrated on top of the microspherical shell structure that enables transduction of the magnetic force experienced by the magnet in e...

Descripción completa

Detalles Bibliográficos
Autores principales: Freeman, Eugene, Wang, Cheng-Yu, Sumaria, Vedant, Schiff, Steven J., Liu, Zhiwen, Tadigadapa, Srinivas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AIP Publishing LLC 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6002270/
https://www.ncbi.nlm.nih.gov/pubmed/29938122
http://dx.doi.org/10.1063/1.5030460
_version_ 1783332167155187712
author Freeman, Eugene
Wang, Cheng-Yu
Sumaria, Vedant
Schiff, Steven J.
Liu, Zhiwen
Tadigadapa, Srinivas
author_facet Freeman, Eugene
Wang, Cheng-Yu
Sumaria, Vedant
Schiff, Steven J.
Liu, Zhiwen
Tadigadapa, Srinivas
author_sort Freeman, Eugene
collection PubMed
description A whispering gallery mode resonator based magnetometer using chip-scale glass microspherical shells is described. A neodynium micro-magnet is elastically coupled and integrated on top of the microspherical shell structure that enables transduction of the magnetic force experienced by the magnet in external magnetic fields into an optical resonance frequency shift. High quality factor optical microspherical shell resonators with ultra-smooth surfaces have been successfully fabricated and integrated with magnets to achieve Q-factors of greater than 1.1 × 10(7) and have shown a resonance shift of 1.43 GHz/mT (or 4.0 pm/mT) at 760 nm wavelength. The main mode of action is mechanical deformation of the microbubble with a minor contribution from the photoelastic effect. An experimental limit of detection of 60 nT Hz(−1/2) at 100 Hz is demonstrated. A theoretical thermorefractive limited detection limit of 52 pT Hz(−1/2) at 100 Hz is calculated from the experimentally derived sensitivity. The paper describes the mode of action, sensitivity and limit of detection is evaluated for the chip-scale whispering gallery mode magnetometer.
format Online
Article
Text
id pubmed-6002270
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher AIP Publishing LLC
record_format MEDLINE/PubMed
spelling pubmed-60022702018-06-22 Chip-scale high Q-factor glassblown microspherical shells for magnetic sensing Freeman, Eugene Wang, Cheng-Yu Sumaria, Vedant Schiff, Steven J. Liu, Zhiwen Tadigadapa, Srinivas AIP Adv Regular Articles A whispering gallery mode resonator based magnetometer using chip-scale glass microspherical shells is described. A neodynium micro-magnet is elastically coupled and integrated on top of the microspherical shell structure that enables transduction of the magnetic force experienced by the magnet in external magnetic fields into an optical resonance frequency shift. High quality factor optical microspherical shell resonators with ultra-smooth surfaces have been successfully fabricated and integrated with magnets to achieve Q-factors of greater than 1.1 × 10(7) and have shown a resonance shift of 1.43 GHz/mT (or 4.0 pm/mT) at 760 nm wavelength. The main mode of action is mechanical deformation of the microbubble with a minor contribution from the photoelastic effect. An experimental limit of detection of 60 nT Hz(−1/2) at 100 Hz is demonstrated. A theoretical thermorefractive limited detection limit of 52 pT Hz(−1/2) at 100 Hz is calculated from the experimentally derived sensitivity. The paper describes the mode of action, sensitivity and limit of detection is evaluated for the chip-scale whispering gallery mode magnetometer. AIP Publishing LLC 2018-06-14 /pmc/articles/PMC6002270/ /pubmed/29938122 http://dx.doi.org/10.1063/1.5030460 Text en © 2018 Author(s). 2158-3226/2018/8(6)/065214/8/$0.00 All article content, except where otherwise noted, is licensed under a Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Regular Articles
Freeman, Eugene
Wang, Cheng-Yu
Sumaria, Vedant
Schiff, Steven J.
Liu, Zhiwen
Tadigadapa, Srinivas
Chip-scale high Q-factor glassblown microspherical shells for magnetic sensing
title Chip-scale high Q-factor glassblown microspherical shells for magnetic sensing
title_full Chip-scale high Q-factor glassblown microspherical shells for magnetic sensing
title_fullStr Chip-scale high Q-factor glassblown microspherical shells for magnetic sensing
title_full_unstemmed Chip-scale high Q-factor glassblown microspherical shells for magnetic sensing
title_short Chip-scale high Q-factor glassblown microspherical shells for magnetic sensing
title_sort chip-scale high q-factor glassblown microspherical shells for magnetic sensing
topic Regular Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6002270/
https://www.ncbi.nlm.nih.gov/pubmed/29938122
http://dx.doi.org/10.1063/1.5030460
work_keys_str_mv AT freemaneugene chipscalehighqfactorglassblownmicrosphericalshellsformagneticsensing
AT wangchengyu chipscalehighqfactorglassblownmicrosphericalshellsformagneticsensing
AT sumariavedant chipscalehighqfactorglassblownmicrosphericalshellsformagneticsensing
AT schiffstevenj chipscalehighqfactorglassblownmicrosphericalshellsformagneticsensing
AT liuzhiwen chipscalehighqfactorglassblownmicrosphericalshellsformagneticsensing
AT tadigadapasrinivas chipscalehighqfactorglassblownmicrosphericalshellsformagneticsensing