Cargando…
Exploring the Difference in Post-procedural Stroke Rates Between Patients with Aortic Stenosis Who Undergo Transcatheter Aortic Valve Replacement Versus Surgical Aortic Valve Replacement
Transcatheter aortic valve replacement (TAVR) is a newer alternative to surgical aortic valve replacement (SAVR) for patients with severe aortic stenosis. Clinical trials have investigated TAVR's safety and effectiveness. Cerebral embolization is a common complication leading to stroke after TA...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6003804/ https://www.ncbi.nlm.nih.gov/pubmed/29922535 http://dx.doi.org/10.7759/cureus.2494 |
_version_ | 1783332414569840640 |
---|---|
author | Burke, Heather Boron, Agnieszka Lee, Jung-Hyun Kahlon, Kudrit Riana |
author_facet | Burke, Heather Boron, Agnieszka Lee, Jung-Hyun Kahlon, Kudrit Riana |
author_sort | Burke, Heather |
collection | PubMed |
description | Transcatheter aortic valve replacement (TAVR) is a newer alternative to surgical aortic valve replacement (SAVR) for patients with severe aortic stenosis. Clinical trials have investigated TAVR's safety and effectiveness. Cerebral embolization is a common complication leading to stroke after TAVR and SAVR; different cerebral protection methods have been studied to prevent this. This paper evaluates the rate of post-procedural stroke rates between TAVR and SAVR and investigates the effect of cerebral protective methods on the stroke risk post-TAVR. Publications on TAVR and SAVR were found using specific criteria on PubMed. The Placement of Aortic Transcatheter Valves 1 (PARTNER 1) and PARTNER 2, the Nordic Aortic Valve Intervention (NOTION), and Surgical Replacement and Transcatheter Aortic Valve Implantation (SURTAVI) trials compared the incidence of complications between TAVR and SAVR. The Action in Diabetes and Vascular Disease: Preterax and Diamicron MR Controlled Evaluation (ADVANCED), CoreValve (Medtronic, Minneapolis, MN), Neurologic Complications of Unprotected Transcatheter Aortic Valve Implantation (Neuro-TAVI), Repositionable Percutaneous Replacement of Stenotic Aortic Valve Through Implantation of Lotus(TM) Valve System (Boston Scientific, Marlborough, MA) - Randomized Clinical Evaluation (REPRISE II), and The Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy (STC/ACC TVT) registry studies further explored the risk of stroke in TAVR. The Effect of Bivalirudin on Aortic Valve Intervention Outcomes (BRAVO)-3 MRI, a prospective randomized evaluation of the TriGuard(TM) HDH (Keystone Heart, Tampa, FL) Embolic Deflection Device During Transcatheter Aortic Valve Replacement (DEFLECT III), Claret Embolic Protection and Transcatheter Aortic Valve Implantation (CLEAN-TAVI), and Cerebral Protection in Transcatheter Aortic Valve Replacement (SENTINEL) trials investigated cerebral protection methods post-TAVR for stroke prevention. In the PARTNER 1 trial, the stroke rate was greater in the TAVR group than in the SAVR group at one year (8.3% vs. 4.3%, P=0.04); the PARTNER 2 trial showed a lower risk of stroke at two years (6.2% and 6.4%, respectively). The NOTION and SURTAVI trials showed no significant difference in stroke rate between TAVR and SAVR at one year (13.1% vs 16.3%, respectively; p = 0.43). An increase in stroke rate after TAVR was found in the ADVANCED trial (5.6% at 31 days - two years) and CoreValve trial (4.3% in the late phase). The Neuro-TAVI trial showed ischemia after TAVR in 20% of patients at discharge. In the STC/ACC TVT Registry, the rate of post-procedure disabling stroke was 1.7% at 30 days. Finally, the BRAVO-3 MRI study showed no advantages between bivalirudin or unfractionated heparin in preventing cerebral lesion formation (65.5% vs 58.1%, respectively; p = 0.55). The DEFLECT III, CLEAN-TAVI, and SENTINEL trials assessed the safety and efficacy of transcatheter cerebral embolic protection devices (CEPDs); their results ranged from 50% improvement (CLEAN-TAVI) to none (DEFLECT III, SENTINEL), therefore, showing non-inferiority of cerebral embolic protection devices for TAVR patients. The clinical trials studied in this paper showed a similar incidence of stroke in both groups, with the majority of TAVR patients developing cerebral lesions. With the addition of cerebral embolic protective devices, this incidence has decreased. |
format | Online Article Text |
id | pubmed-6003804 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-60038042018-06-19 Exploring the Difference in Post-procedural Stroke Rates Between Patients with Aortic Stenosis Who Undergo Transcatheter Aortic Valve Replacement Versus Surgical Aortic Valve Replacement Burke, Heather Boron, Agnieszka Lee, Jung-Hyun Kahlon, Kudrit Riana Cureus Cardiac/Thoracic/Vascular Surgery Transcatheter aortic valve replacement (TAVR) is a newer alternative to surgical aortic valve replacement (SAVR) for patients with severe aortic stenosis. Clinical trials have investigated TAVR's safety and effectiveness. Cerebral embolization is a common complication leading to stroke after TAVR and SAVR; different cerebral protection methods have been studied to prevent this. This paper evaluates the rate of post-procedural stroke rates between TAVR and SAVR and investigates the effect of cerebral protective methods on the stroke risk post-TAVR. Publications on TAVR and SAVR were found using specific criteria on PubMed. The Placement of Aortic Transcatheter Valves 1 (PARTNER 1) and PARTNER 2, the Nordic Aortic Valve Intervention (NOTION), and Surgical Replacement and Transcatheter Aortic Valve Implantation (SURTAVI) trials compared the incidence of complications between TAVR and SAVR. The Action in Diabetes and Vascular Disease: Preterax and Diamicron MR Controlled Evaluation (ADVANCED), CoreValve (Medtronic, Minneapolis, MN), Neurologic Complications of Unprotected Transcatheter Aortic Valve Implantation (Neuro-TAVI), Repositionable Percutaneous Replacement of Stenotic Aortic Valve Through Implantation of Lotus(TM) Valve System (Boston Scientific, Marlborough, MA) - Randomized Clinical Evaluation (REPRISE II), and The Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy (STC/ACC TVT) registry studies further explored the risk of stroke in TAVR. The Effect of Bivalirudin on Aortic Valve Intervention Outcomes (BRAVO)-3 MRI, a prospective randomized evaluation of the TriGuard(TM) HDH (Keystone Heart, Tampa, FL) Embolic Deflection Device During Transcatheter Aortic Valve Replacement (DEFLECT III), Claret Embolic Protection and Transcatheter Aortic Valve Implantation (CLEAN-TAVI), and Cerebral Protection in Transcatheter Aortic Valve Replacement (SENTINEL) trials investigated cerebral protection methods post-TAVR for stroke prevention. In the PARTNER 1 trial, the stroke rate was greater in the TAVR group than in the SAVR group at one year (8.3% vs. 4.3%, P=0.04); the PARTNER 2 trial showed a lower risk of stroke at two years (6.2% and 6.4%, respectively). The NOTION and SURTAVI trials showed no significant difference in stroke rate between TAVR and SAVR at one year (13.1% vs 16.3%, respectively; p = 0.43). An increase in stroke rate after TAVR was found in the ADVANCED trial (5.6% at 31 days - two years) and CoreValve trial (4.3% in the late phase). The Neuro-TAVI trial showed ischemia after TAVR in 20% of patients at discharge. In the STC/ACC TVT Registry, the rate of post-procedure disabling stroke was 1.7% at 30 days. Finally, the BRAVO-3 MRI study showed no advantages between bivalirudin or unfractionated heparin in preventing cerebral lesion formation (65.5% vs 58.1%, respectively; p = 0.55). The DEFLECT III, CLEAN-TAVI, and SENTINEL trials assessed the safety and efficacy of transcatheter cerebral embolic protection devices (CEPDs); their results ranged from 50% improvement (CLEAN-TAVI) to none (DEFLECT III, SENTINEL), therefore, showing non-inferiority of cerebral embolic protection devices for TAVR patients. The clinical trials studied in this paper showed a similar incidence of stroke in both groups, with the majority of TAVR patients developing cerebral lesions. With the addition of cerebral embolic protective devices, this incidence has decreased. Cureus 2018-04-17 /pmc/articles/PMC6003804/ /pubmed/29922535 http://dx.doi.org/10.7759/cureus.2494 Text en Copyright © 2018, Burke et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Cardiac/Thoracic/Vascular Surgery Burke, Heather Boron, Agnieszka Lee, Jung-Hyun Kahlon, Kudrit Riana Exploring the Difference in Post-procedural Stroke Rates Between Patients with Aortic Stenosis Who Undergo Transcatheter Aortic Valve Replacement Versus Surgical Aortic Valve Replacement |
title | Exploring the Difference in Post-procedural Stroke Rates Between Patients with Aortic Stenosis Who Undergo Transcatheter Aortic Valve Replacement Versus Surgical Aortic Valve Replacement |
title_full | Exploring the Difference in Post-procedural Stroke Rates Between Patients with Aortic Stenosis Who Undergo Transcatheter Aortic Valve Replacement Versus Surgical Aortic Valve Replacement |
title_fullStr | Exploring the Difference in Post-procedural Stroke Rates Between Patients with Aortic Stenosis Who Undergo Transcatheter Aortic Valve Replacement Versus Surgical Aortic Valve Replacement |
title_full_unstemmed | Exploring the Difference in Post-procedural Stroke Rates Between Patients with Aortic Stenosis Who Undergo Transcatheter Aortic Valve Replacement Versus Surgical Aortic Valve Replacement |
title_short | Exploring the Difference in Post-procedural Stroke Rates Between Patients with Aortic Stenosis Who Undergo Transcatheter Aortic Valve Replacement Versus Surgical Aortic Valve Replacement |
title_sort | exploring the difference in post-procedural stroke rates between patients with aortic stenosis who undergo transcatheter aortic valve replacement versus surgical aortic valve replacement |
topic | Cardiac/Thoracic/Vascular Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6003804/ https://www.ncbi.nlm.nih.gov/pubmed/29922535 http://dx.doi.org/10.7759/cureus.2494 |
work_keys_str_mv | AT burkeheather exploringthedifferenceinpostproceduralstrokeratesbetweenpatientswithaorticstenosiswhoundergotranscatheteraorticvalvereplacementversussurgicalaorticvalvereplacement AT boronagnieszka exploringthedifferenceinpostproceduralstrokeratesbetweenpatientswithaorticstenosiswhoundergotranscatheteraorticvalvereplacementversussurgicalaorticvalvereplacement AT leejunghyun exploringthedifferenceinpostproceduralstrokeratesbetweenpatientswithaorticstenosiswhoundergotranscatheteraorticvalvereplacementversussurgicalaorticvalvereplacement AT kahlonkudritriana exploringthedifferenceinpostproceduralstrokeratesbetweenpatientswithaorticstenosiswhoundergotranscatheteraorticvalvereplacementversussurgicalaorticvalvereplacement |