Speckle tracking stress echocardiography in children: interobserver and intraobserver reproducibility and the impact of echocardiographic image quality

Speckle tracking echocardiography (STE) is increasingly used during functional assessments. However, reproducibility and dependence on echocardiographic image quality for speckle tracking stress echocardiography in pediatric patients have not been studied to date. 127 consecutive normotensive childr...

Descripción completa

Detalles Bibliográficos
Autores principales: Wilke, Lucia, Abellan Schneyder, Francisca E., Roskopf, Markus, Jenke, Andreas C., Heusch, Andreas, Hensel, Kai O.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6003923/
https://www.ncbi.nlm.nih.gov/pubmed/29907818
http://dx.doi.org/10.1038/s41598-018-27412-2
_version_ 1783332424821768192
author Wilke, Lucia
Abellan Schneyder, Francisca E.
Roskopf, Markus
Jenke, Andreas C.
Heusch, Andreas
Hensel, Kai O.
author_facet Wilke, Lucia
Abellan Schneyder, Francisca E.
Roskopf, Markus
Jenke, Andreas C.
Heusch, Andreas
Hensel, Kai O.
author_sort Wilke, Lucia
collection PubMed
description Speckle tracking echocardiography (STE) is increasingly used during functional assessments. However, reproducibility and dependence on echocardiographic image quality for speckle tracking stress echocardiography in pediatric patients have not been studied to date. 127 consecutive normotensive children without structural heart disease (mean age 13.4 ± 3.0 years, 50.4% female) underwent a stepwise semisupine cycle ergometric protocol. Left ventricular (LV) myocardial peak strain and strain rate were assessed at rest and during exercise. Interobserver and intraobserver assessments were performed and analyzed regarding echocardiographic image quality. LV peak global strain and strain rate were well reproducible with narrow limits of agreement without any significant bias both at rest and during all stages of exercise testing. Moreover, strain rate reproducibility slightly deteriorated in values between −1.5 and −3 s(−1). Surprisingly, there was no significant difference in reproducibility between optimal, intermediate and poor quality of echocardiographic images. STE derived strain and strain rate measurements in children are feasible and highly reproducible during semisupine cycle ergometric stress echocardiography. Echocardiographic image quality does not seem to influence strain (rate) reproducibility. Myocardial deformation measurements in images with suboptimal visualization quality must be interpreted with caution.
format Online
Article
Text
id pubmed-6003923
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-60039232018-06-26 Speckle tracking stress echocardiography in children: interobserver and intraobserver reproducibility and the impact of echocardiographic image quality Wilke, Lucia Abellan Schneyder, Francisca E. Roskopf, Markus Jenke, Andreas C. Heusch, Andreas Hensel, Kai O. Sci Rep Article Speckle tracking echocardiography (STE) is increasingly used during functional assessments. However, reproducibility and dependence on echocardiographic image quality for speckle tracking stress echocardiography in pediatric patients have not been studied to date. 127 consecutive normotensive children without structural heart disease (mean age 13.4 ± 3.0 years, 50.4% female) underwent a stepwise semisupine cycle ergometric protocol. Left ventricular (LV) myocardial peak strain and strain rate were assessed at rest and during exercise. Interobserver and intraobserver assessments were performed and analyzed regarding echocardiographic image quality. LV peak global strain and strain rate were well reproducible with narrow limits of agreement without any significant bias both at rest and during all stages of exercise testing. Moreover, strain rate reproducibility slightly deteriorated in values between −1.5 and −3 s(−1). Surprisingly, there was no significant difference in reproducibility between optimal, intermediate and poor quality of echocardiographic images. STE derived strain and strain rate measurements in children are feasible and highly reproducible during semisupine cycle ergometric stress echocardiography. Echocardiographic image quality does not seem to influence strain (rate) reproducibility. Myocardial deformation measurements in images with suboptimal visualization quality must be interpreted with caution. Nature Publishing Group UK 2018-06-15 /pmc/articles/PMC6003923/ /pubmed/29907818 http://dx.doi.org/10.1038/s41598-018-27412-2 Text en © The Author(s) 2018 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Wilke, Lucia
Abellan Schneyder, Francisca E.
Roskopf, Markus
Jenke, Andreas C.
Heusch, Andreas
Hensel, Kai O.
Speckle tracking stress echocardiography in children: interobserver and intraobserver reproducibility and the impact of echocardiographic image quality
title Speckle tracking stress echocardiography in children: interobserver and intraobserver reproducibility and the impact of echocardiographic image quality
title_full Speckle tracking stress echocardiography in children: interobserver and intraobserver reproducibility and the impact of echocardiographic image quality
title_fullStr Speckle tracking stress echocardiography in children: interobserver and intraobserver reproducibility and the impact of echocardiographic image quality
title_full_unstemmed Speckle tracking stress echocardiography in children: interobserver and intraobserver reproducibility and the impact of echocardiographic image quality
title_short Speckle tracking stress echocardiography in children: interobserver and intraobserver reproducibility and the impact of echocardiographic image quality
title_sort speckle tracking stress echocardiography in children: interobserver and intraobserver reproducibility and the impact of echocardiographic image quality
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6003923/
https://www.ncbi.nlm.nih.gov/pubmed/29907818
http://dx.doi.org/10.1038/s41598-018-27412-2
work_keys_str_mv AT wilkelucia speckletrackingstressechocardiographyinchildreninterobserverandintraobserverreproducibilityandtheimpactofechocardiographicimagequality
AT abellanschneyderfranciscae speckletrackingstressechocardiographyinchildreninterobserverandintraobserverreproducibilityandtheimpactofechocardiographicimagequality
AT roskopfmarkus speckletrackingstressechocardiographyinchildreninterobserverandintraobserverreproducibilityandtheimpactofechocardiographicimagequality
AT jenkeandreasc speckletrackingstressechocardiographyinchildreninterobserverandintraobserverreproducibilityandtheimpactofechocardiographicimagequality
AT heuschandreas speckletrackingstressechocardiographyinchildreninterobserverandintraobserverreproducibilityandtheimpactofechocardiographicimagequality
AT henselkaio speckletrackingstressechocardiographyinchildreninterobserverandintraobserverreproducibilityandtheimpactofechocardiographicimagequality