Cargando…
The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs
PURPOSE: Implant site preparation may be adjusted to achieve the maximum possible primary stability. The aim of this investigation was to study the relation among bone-to-implant contact at insertion, bone density, and implant primary stability intra-operatively measured by a torque-measuring implan...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Prosthodontics
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6004356/ https://www.ncbi.nlm.nih.gov/pubmed/29930793 http://dx.doi.org/10.4047/jap.2018.10.3.227 |
_version_ | 1783332504189534208 |
---|---|
author | Di Stefano, Danilo Alessio Perrotti, Vittoria Greco, Gian Battista Cappucci, Claudia Arosio, Paolo Piattelli, Adriano Iezzi, Giovanna |
author_facet | Di Stefano, Danilo Alessio Perrotti, Vittoria Greco, Gian Battista Cappucci, Claudia Arosio, Paolo Piattelli, Adriano Iezzi, Giovanna |
author_sort | Di Stefano, Danilo Alessio |
collection | PubMed |
description | PURPOSE: Implant site preparation may be adjusted to achieve the maximum possible primary stability. The aim of this investigation was to study the relation among bone-to-implant contact at insertion, bone density, and implant primary stability intra-operatively measured by a torque-measuring implant motor, when implant sites were undersized or tapped. MATERIALS AND METHODS: Undersized (n=14), standard (n=13), and tapped (n=13) implant sites were prepared on 9 segments of bovine ribs. After measuring bone density using the implant motor, 40 implants were placed, and their primary stability assessed by measuring the integral of the torque-depth insertion curve. Bovine ribs were then processed histologically, the bone-to-implant contact measured and statistically correlated to bone density and the integral. RESULTS: Bone-to-implant contact and the integral of the torque-depth curve were significantly greater for undersized sites than tapped sites. Moreover, a correlation between bone to implant contact, the integral and bone density was found under all preparation conditions. The slope of the bone-to-implant/density and integral/density lines was significantly greater for undersized sites, while those corresponding to standard prepared and tapped sites did not differ significantly. CONCLUSION: The integral of the torque-depth curve provided reliable information about bone-to-implant contact and primary implant stability even in tapped or undersized sites. The linear relations found among the parameters suggests a connection between extent and modality of undersizing and the corresponding increase of the integral and, consequently, of primary stability. These results might help the physician determine the extent of undersizing needed to achieve the proper implant primary stability, according to the planned loading protocol. |
format | Online Article Text |
id | pubmed-6004356 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | The Korean Academy of Prosthodontics |
record_format | MEDLINE/PubMed |
spelling | pubmed-60043562018-06-21 The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs Di Stefano, Danilo Alessio Perrotti, Vittoria Greco, Gian Battista Cappucci, Claudia Arosio, Paolo Piattelli, Adriano Iezzi, Giovanna J Adv Prosthodont Original Article PURPOSE: Implant site preparation may be adjusted to achieve the maximum possible primary stability. The aim of this investigation was to study the relation among bone-to-implant contact at insertion, bone density, and implant primary stability intra-operatively measured by a torque-measuring implant motor, when implant sites were undersized or tapped. MATERIALS AND METHODS: Undersized (n=14), standard (n=13), and tapped (n=13) implant sites were prepared on 9 segments of bovine ribs. After measuring bone density using the implant motor, 40 implants were placed, and their primary stability assessed by measuring the integral of the torque-depth insertion curve. Bovine ribs were then processed histologically, the bone-to-implant contact measured and statistically correlated to bone density and the integral. RESULTS: Bone-to-implant contact and the integral of the torque-depth curve were significantly greater for undersized sites than tapped sites. Moreover, a correlation between bone to implant contact, the integral and bone density was found under all preparation conditions. The slope of the bone-to-implant/density and integral/density lines was significantly greater for undersized sites, while those corresponding to standard prepared and tapped sites did not differ significantly. CONCLUSION: The integral of the torque-depth curve provided reliable information about bone-to-implant contact and primary implant stability even in tapped or undersized sites. The linear relations found among the parameters suggests a connection between extent and modality of undersizing and the corresponding increase of the integral and, consequently, of primary stability. These results might help the physician determine the extent of undersizing needed to achieve the proper implant primary stability, according to the planned loading protocol. The Korean Academy of Prosthodontics 2018-06 2018-06-12 /pmc/articles/PMC6004356/ /pubmed/29930793 http://dx.doi.org/10.4047/jap.2018.10.3.227 Text en © 2018 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Di Stefano, Danilo Alessio Perrotti, Vittoria Greco, Gian Battista Cappucci, Claudia Arosio, Paolo Piattelli, Adriano Iezzi, Giovanna The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs |
title | The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs |
title_full | The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs |
title_fullStr | The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs |
title_full_unstemmed | The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs |
title_short | The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs |
title_sort | effect of undersizing and tapping on bone to implant contact and implant primary stability: a histomorphometric study on bovine ribs |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6004356/ https://www.ncbi.nlm.nih.gov/pubmed/29930793 http://dx.doi.org/10.4047/jap.2018.10.3.227 |
work_keys_str_mv | AT distefanodaniloalessio theeffectofundersizingandtappingonbonetoimplantcontactandimplantprimarystabilityahistomorphometricstudyonbovineribs AT perrottivittoria theeffectofundersizingandtappingonbonetoimplantcontactandimplantprimarystabilityahistomorphometricstudyonbovineribs AT grecogianbattista theeffectofundersizingandtappingonbonetoimplantcontactandimplantprimarystabilityahistomorphometricstudyonbovineribs AT cappucciclaudia theeffectofundersizingandtappingonbonetoimplantcontactandimplantprimarystabilityahistomorphometricstudyonbovineribs AT arosiopaolo theeffectofundersizingandtappingonbonetoimplantcontactandimplantprimarystabilityahistomorphometricstudyonbovineribs AT piattelliadriano theeffectofundersizingandtappingonbonetoimplantcontactandimplantprimarystabilityahistomorphometricstudyonbovineribs AT iezzigiovanna theeffectofundersizingandtappingonbonetoimplantcontactandimplantprimarystabilityahistomorphometricstudyonbovineribs AT distefanodaniloalessio effectofundersizingandtappingonbonetoimplantcontactandimplantprimarystabilityahistomorphometricstudyonbovineribs AT perrottivittoria effectofundersizingandtappingonbonetoimplantcontactandimplantprimarystabilityahistomorphometricstudyonbovineribs AT grecogianbattista effectofundersizingandtappingonbonetoimplantcontactandimplantprimarystabilityahistomorphometricstudyonbovineribs AT cappucciclaudia effectofundersizingandtappingonbonetoimplantcontactandimplantprimarystabilityahistomorphometricstudyonbovineribs AT arosiopaolo effectofundersizingandtappingonbonetoimplantcontactandimplantprimarystabilityahistomorphometricstudyonbovineribs AT piattelliadriano effectofundersizingandtappingonbonetoimplantcontactandimplantprimarystabilityahistomorphometricstudyonbovineribs AT iezzigiovanna effectofundersizingandtappingonbonetoimplantcontactandimplantprimarystabilityahistomorphometricstudyonbovineribs |