Cargando…

The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs

PURPOSE: Implant site preparation may be adjusted to achieve the maximum possible primary stability. The aim of this investigation was to study the relation among bone-to-implant contact at insertion, bone density, and implant primary stability intra-operatively measured by a torque-measuring implan...

Descripción completa

Detalles Bibliográficos
Autores principales: Di Stefano, Danilo Alessio, Perrotti, Vittoria, Greco, Gian Battista, Cappucci, Claudia, Arosio, Paolo, Piattelli, Adriano, Iezzi, Giovanna
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6004356/
https://www.ncbi.nlm.nih.gov/pubmed/29930793
http://dx.doi.org/10.4047/jap.2018.10.3.227
_version_ 1783332504189534208
author Di Stefano, Danilo Alessio
Perrotti, Vittoria
Greco, Gian Battista
Cappucci, Claudia
Arosio, Paolo
Piattelli, Adriano
Iezzi, Giovanna
author_facet Di Stefano, Danilo Alessio
Perrotti, Vittoria
Greco, Gian Battista
Cappucci, Claudia
Arosio, Paolo
Piattelli, Adriano
Iezzi, Giovanna
author_sort Di Stefano, Danilo Alessio
collection PubMed
description PURPOSE: Implant site preparation may be adjusted to achieve the maximum possible primary stability. The aim of this investigation was to study the relation among bone-to-implant contact at insertion, bone density, and implant primary stability intra-operatively measured by a torque-measuring implant motor, when implant sites were undersized or tapped. MATERIALS AND METHODS: Undersized (n=14), standard (n=13), and tapped (n=13) implant sites were prepared on 9 segments of bovine ribs. After measuring bone density using the implant motor, 40 implants were placed, and their primary stability assessed by measuring the integral of the torque-depth insertion curve. Bovine ribs were then processed histologically, the bone-to-implant contact measured and statistically correlated to bone density and the integral. RESULTS: Bone-to-implant contact and the integral of the torque-depth curve were significantly greater for undersized sites than tapped sites. Moreover, a correlation between bone to implant contact, the integral and bone density was found under all preparation conditions. The slope of the bone-to-implant/density and integral/density lines was significantly greater for undersized sites, while those corresponding to standard prepared and tapped sites did not differ significantly. CONCLUSION: The integral of the torque-depth curve provided reliable information about bone-to-implant contact and primary implant stability even in tapped or undersized sites. The linear relations found among the parameters suggests a connection between extent and modality of undersizing and the corresponding increase of the integral and, consequently, of primary stability. These results might help the physician determine the extent of undersizing needed to achieve the proper implant primary stability, according to the planned loading protocol.
format Online
Article
Text
id pubmed-6004356
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-60043562018-06-21 The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs Di Stefano, Danilo Alessio Perrotti, Vittoria Greco, Gian Battista Cappucci, Claudia Arosio, Paolo Piattelli, Adriano Iezzi, Giovanna J Adv Prosthodont Original Article PURPOSE: Implant site preparation may be adjusted to achieve the maximum possible primary stability. The aim of this investigation was to study the relation among bone-to-implant contact at insertion, bone density, and implant primary stability intra-operatively measured by a torque-measuring implant motor, when implant sites were undersized or tapped. MATERIALS AND METHODS: Undersized (n=14), standard (n=13), and tapped (n=13) implant sites were prepared on 9 segments of bovine ribs. After measuring bone density using the implant motor, 40 implants were placed, and their primary stability assessed by measuring the integral of the torque-depth insertion curve. Bovine ribs were then processed histologically, the bone-to-implant contact measured and statistically correlated to bone density and the integral. RESULTS: Bone-to-implant contact and the integral of the torque-depth curve were significantly greater for undersized sites than tapped sites. Moreover, a correlation between bone to implant contact, the integral and bone density was found under all preparation conditions. The slope of the bone-to-implant/density and integral/density lines was significantly greater for undersized sites, while those corresponding to standard prepared and tapped sites did not differ significantly. CONCLUSION: The integral of the torque-depth curve provided reliable information about bone-to-implant contact and primary implant stability even in tapped or undersized sites. The linear relations found among the parameters suggests a connection between extent and modality of undersizing and the corresponding increase of the integral and, consequently, of primary stability. These results might help the physician determine the extent of undersizing needed to achieve the proper implant primary stability, according to the planned loading protocol. The Korean Academy of Prosthodontics 2018-06 2018-06-12 /pmc/articles/PMC6004356/ /pubmed/29930793 http://dx.doi.org/10.4047/jap.2018.10.3.227 Text en © 2018 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Di Stefano, Danilo Alessio
Perrotti, Vittoria
Greco, Gian Battista
Cappucci, Claudia
Arosio, Paolo
Piattelli, Adriano
Iezzi, Giovanna
The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs
title The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs
title_full The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs
title_fullStr The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs
title_full_unstemmed The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs
title_short The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs
title_sort effect of undersizing and tapping on bone to implant contact and implant primary stability: a histomorphometric study on bovine ribs
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6004356/
https://www.ncbi.nlm.nih.gov/pubmed/29930793
http://dx.doi.org/10.4047/jap.2018.10.3.227
work_keys_str_mv AT distefanodaniloalessio theeffectofundersizingandtappingonbonetoimplantcontactandimplantprimarystabilityahistomorphometricstudyonbovineribs
AT perrottivittoria theeffectofundersizingandtappingonbonetoimplantcontactandimplantprimarystabilityahistomorphometricstudyonbovineribs
AT grecogianbattista theeffectofundersizingandtappingonbonetoimplantcontactandimplantprimarystabilityahistomorphometricstudyonbovineribs
AT cappucciclaudia theeffectofundersizingandtappingonbonetoimplantcontactandimplantprimarystabilityahistomorphometricstudyonbovineribs
AT arosiopaolo theeffectofundersizingandtappingonbonetoimplantcontactandimplantprimarystabilityahistomorphometricstudyonbovineribs
AT piattelliadriano theeffectofundersizingandtappingonbonetoimplantcontactandimplantprimarystabilityahistomorphometricstudyonbovineribs
AT iezzigiovanna theeffectofundersizingandtappingonbonetoimplantcontactandimplantprimarystabilityahistomorphometricstudyonbovineribs
AT distefanodaniloalessio effectofundersizingandtappingonbonetoimplantcontactandimplantprimarystabilityahistomorphometricstudyonbovineribs
AT perrottivittoria effectofundersizingandtappingonbonetoimplantcontactandimplantprimarystabilityahistomorphometricstudyonbovineribs
AT grecogianbattista effectofundersizingandtappingonbonetoimplantcontactandimplantprimarystabilityahistomorphometricstudyonbovineribs
AT cappucciclaudia effectofundersizingandtappingonbonetoimplantcontactandimplantprimarystabilityahistomorphometricstudyonbovineribs
AT arosiopaolo effectofundersizingandtappingonbonetoimplantcontactandimplantprimarystabilityahistomorphometricstudyonbovineribs
AT piattelliadriano effectofundersizingandtappingonbonetoimplantcontactandimplantprimarystabilityahistomorphometricstudyonbovineribs
AT iezzigiovanna effectofundersizingandtappingonbonetoimplantcontactandimplantprimarystabilityahistomorphometricstudyonbovineribs