Cargando…

Impact of surgical pulmonary valve replacement on ventricular strain and synchrony in patients with repaired tetralogy of Fallot: a cardiovascular magnetic resonance feature tracking study

BACKGROUND: In patients with repaired tetralogy of Fallot (TOF), a better understanding of the impact of surgical pulmonary valve replacement (PVR) on ventricular mechanics may lead to improved indications and outcomes. Therefore, we used cardiovascular magnetic resonance (CMR) feature tracking anal...

Descripción completa

Detalles Bibliográficos
Autores principales: Balasubramanian, Sowmya, Harrild, David M., Kerur, Basavaraj, Marcus, Edward, del Nido, Pedro, Geva, Tal, Powell, Andrew J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6004693/
https://www.ncbi.nlm.nih.gov/pubmed/29909772
http://dx.doi.org/10.1186/s12968-018-0460-0
_version_ 1783332564875870208
author Balasubramanian, Sowmya
Harrild, David M.
Kerur, Basavaraj
Marcus, Edward
del Nido, Pedro
Geva, Tal
Powell, Andrew J.
author_facet Balasubramanian, Sowmya
Harrild, David M.
Kerur, Basavaraj
Marcus, Edward
del Nido, Pedro
Geva, Tal
Powell, Andrew J.
author_sort Balasubramanian, Sowmya
collection PubMed
description BACKGROUND: In patients with repaired tetralogy of Fallot (TOF), a better understanding of the impact of surgical pulmonary valve replacement (PVR) on ventricular mechanics may lead to improved indications and outcomes. Therefore, we used cardiovascular magnetic resonance (CMR) feature tracking analysis to quantify ventricular strain and synchrony in repaired TOF patients before and after PVR. METHODS: Thirty-six repaired TOF patients (median age 22.4 years) prospectively underwent CMR a mean of 4.5 ± 3.8 months before PVR surgery and 7.3 ± 2.1 months after PVR surgery. Feature tracking analysis on cine steady-state free precession images was used to measure right ventricular (RV) and left ventricular (LV) circumferential strain from short-axis views at basal, mid-ventricular, and apical levels; and longitudinal strain from 4-chamber views. Intraventricular synchrony was quantified using the maximum difference in time-to-peak strain, the standard deviation of the time-to-peak, and cross correlation delay (CCD) metrics; interventricular synchrony was assessed using the CCD metric. RESULTS: Following PVR, RV end-diastolic volume, end-systolic volume, and ejection fraction declined, and LV end-diastolic volume and end-systolic volume both increased with no significant change in the LV ejection fraction. LV global basal and apical circumferential strains, and basal synchrony improved. RV global circumferential and longitudinal strains were unchanged, and there was a varied impact on synchrony across the locations. Interventricular synchrony worsened at the midventricular level but was unchanged at the base and apex, and on 4-chamber views. CONCLUSIONS: Surgical PVR in repaired TOF patients led to improved LV global strain and no change in RV global strain. LV and RV synchrony parameters improved or were unchanged, and interventricular synchrony worsened at the midventricular level.
format Online
Article
Text
id pubmed-6004693
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-60046932018-06-26 Impact of surgical pulmonary valve replacement on ventricular strain and synchrony in patients with repaired tetralogy of Fallot: a cardiovascular magnetic resonance feature tracking study Balasubramanian, Sowmya Harrild, David M. Kerur, Basavaraj Marcus, Edward del Nido, Pedro Geva, Tal Powell, Andrew J. J Cardiovasc Magn Reson Research BACKGROUND: In patients with repaired tetralogy of Fallot (TOF), a better understanding of the impact of surgical pulmonary valve replacement (PVR) on ventricular mechanics may lead to improved indications and outcomes. Therefore, we used cardiovascular magnetic resonance (CMR) feature tracking analysis to quantify ventricular strain and synchrony in repaired TOF patients before and after PVR. METHODS: Thirty-six repaired TOF patients (median age 22.4 years) prospectively underwent CMR a mean of 4.5 ± 3.8 months before PVR surgery and 7.3 ± 2.1 months after PVR surgery. Feature tracking analysis on cine steady-state free precession images was used to measure right ventricular (RV) and left ventricular (LV) circumferential strain from short-axis views at basal, mid-ventricular, and apical levels; and longitudinal strain from 4-chamber views. Intraventricular synchrony was quantified using the maximum difference in time-to-peak strain, the standard deviation of the time-to-peak, and cross correlation delay (CCD) metrics; interventricular synchrony was assessed using the CCD metric. RESULTS: Following PVR, RV end-diastolic volume, end-systolic volume, and ejection fraction declined, and LV end-diastolic volume and end-systolic volume both increased with no significant change in the LV ejection fraction. LV global basal and apical circumferential strains, and basal synchrony improved. RV global circumferential and longitudinal strains were unchanged, and there was a varied impact on synchrony across the locations. Interventricular synchrony worsened at the midventricular level but was unchanged at the base and apex, and on 4-chamber views. CONCLUSIONS: Surgical PVR in repaired TOF patients led to improved LV global strain and no change in RV global strain. LV and RV synchrony parameters improved or were unchanged, and interventricular synchrony worsened at the midventricular level. BioMed Central 2018-06-18 /pmc/articles/PMC6004693/ /pubmed/29909772 http://dx.doi.org/10.1186/s12968-018-0460-0 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Balasubramanian, Sowmya
Harrild, David M.
Kerur, Basavaraj
Marcus, Edward
del Nido, Pedro
Geva, Tal
Powell, Andrew J.
Impact of surgical pulmonary valve replacement on ventricular strain and synchrony in patients with repaired tetralogy of Fallot: a cardiovascular magnetic resonance feature tracking study
title Impact of surgical pulmonary valve replacement on ventricular strain and synchrony in patients with repaired tetralogy of Fallot: a cardiovascular magnetic resonance feature tracking study
title_full Impact of surgical pulmonary valve replacement on ventricular strain and synchrony in patients with repaired tetralogy of Fallot: a cardiovascular magnetic resonance feature tracking study
title_fullStr Impact of surgical pulmonary valve replacement on ventricular strain and synchrony in patients with repaired tetralogy of Fallot: a cardiovascular magnetic resonance feature tracking study
title_full_unstemmed Impact of surgical pulmonary valve replacement on ventricular strain and synchrony in patients with repaired tetralogy of Fallot: a cardiovascular magnetic resonance feature tracking study
title_short Impact of surgical pulmonary valve replacement on ventricular strain and synchrony in patients with repaired tetralogy of Fallot: a cardiovascular magnetic resonance feature tracking study
title_sort impact of surgical pulmonary valve replacement on ventricular strain and synchrony in patients with repaired tetralogy of fallot: a cardiovascular magnetic resonance feature tracking study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6004693/
https://www.ncbi.nlm.nih.gov/pubmed/29909772
http://dx.doi.org/10.1186/s12968-018-0460-0
work_keys_str_mv AT balasubramaniansowmya impactofsurgicalpulmonaryvalvereplacementonventricularstrainandsynchronyinpatientswithrepairedtetralogyoffallotacardiovascularmagneticresonancefeaturetrackingstudy
AT harrilddavidm impactofsurgicalpulmonaryvalvereplacementonventricularstrainandsynchronyinpatientswithrepairedtetralogyoffallotacardiovascularmagneticresonancefeaturetrackingstudy
AT kerurbasavaraj impactofsurgicalpulmonaryvalvereplacementonventricularstrainandsynchronyinpatientswithrepairedtetralogyoffallotacardiovascularmagneticresonancefeaturetrackingstudy
AT marcusedward impactofsurgicalpulmonaryvalvereplacementonventricularstrainandsynchronyinpatientswithrepairedtetralogyoffallotacardiovascularmagneticresonancefeaturetrackingstudy
AT delnidopedro impactofsurgicalpulmonaryvalvereplacementonventricularstrainandsynchronyinpatientswithrepairedtetralogyoffallotacardiovascularmagneticresonancefeaturetrackingstudy
AT gevatal impactofsurgicalpulmonaryvalvereplacementonventricularstrainandsynchronyinpatientswithrepairedtetralogyoffallotacardiovascularmagneticresonancefeaturetrackingstudy
AT powellandrewj impactofsurgicalpulmonaryvalvereplacementonventricularstrainandsynchronyinpatientswithrepairedtetralogyoffallotacardiovascularmagneticresonancefeaturetrackingstudy