Influence of chloramine-T disinfection on elastomeric impression stability

OBJECTIVE: The aim of this study was to evaluate the stability of elastomer through detail reproduction and its dimensional stability (DS) after disinfection with 0.2% chloramine-T. MATERIALS AND METHODS: The elastomeric impression dental materials used in this study were polydimethylsiloxane (Oranw...

Descripción completa

Detalles Bibliográficos
Autores principales: Guiraldo, Ricardo Danil, Berger, Sandrine Bittencourt, Punhagui, Marilia Franco, Moretto, Thais Staut, Lopes, Murilo Baena, Gonini-Júnior, Alcides, Coelho Sinhoreti, Mário Alexandre
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6004818/
https://www.ncbi.nlm.nih.gov/pubmed/29988249
http://dx.doi.org/10.4103/ejd.ejd_195_17
_version_ 1783332590186397696
author Guiraldo, Ricardo Danil
Berger, Sandrine Bittencourt
Punhagui, Marilia Franco
Moretto, Thais Staut
Lopes, Murilo Baena
Gonini-Júnior, Alcides
Coelho Sinhoreti, Mário Alexandre
author_facet Guiraldo, Ricardo Danil
Berger, Sandrine Bittencourt
Punhagui, Marilia Franco
Moretto, Thais Staut
Lopes, Murilo Baena
Gonini-Júnior, Alcides
Coelho Sinhoreti, Mário Alexandre
author_sort Guiraldo, Ricardo Danil
collection PubMed
description OBJECTIVE: The aim of this study was to evaluate the stability of elastomer through detail reproduction and its dimensional stability (DS) after disinfection with 0.2% chloramine-T. MATERIALS AND METHODS: The elastomeric impression dental materials used in this study were polydimethylsiloxane (Oranwash L), polyvinyl siloxane (Express), polysulfide (Permlastic), and polyether (Impregum Soft). The entire press procedure was performed on a matrix in accordance with the ISO 4823. Detail reproduction was analyzed using an optical microscope (Stereozoom Microscope) over the 20-μm line with 25 mm of length at a magnification of ×4. DS was measured using an optical microscope (Scanning Tunneling Microscope) by subtracting the distance between the lines X and X' over the 20-μm line on the matrix (DM) from the distance between the lines on the impression material (DI) divided by DM and multiplied by 100 establishing the equation: DS = ([DI – DM]/DM) ×100; then, 100% was added to the results of the equation. The detail reproduction values were subsequently subjected to descriptive analysis by percentage (%), and the DS values (%) were submitted to Kolmogorov–Smirnov test, two-way ANOVA (material × disinfectant), and Tukey's test (α = 0.05). RESULTS: All elastomeric impression materials showed 100% of detail reproduction, regardless of the disinfection procedure. Polysulfide (not disinfected) and polysulfide and polydimethylsiloxane (after disinfection with 0.2% chloramine-T) showed the smaller mean values of DS. CONCLUSION: According to the stability properties analyzed, chloramine-T can be used for disinfection of elastomer molds.
format Online
Article
Text
id pubmed-6004818
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-60048182018-07-09 Influence of chloramine-T disinfection on elastomeric impression stability Guiraldo, Ricardo Danil Berger, Sandrine Bittencourt Punhagui, Marilia Franco Moretto, Thais Staut Lopes, Murilo Baena Gonini-Júnior, Alcides Coelho Sinhoreti, Mário Alexandre Eur J Dent Original Article OBJECTIVE: The aim of this study was to evaluate the stability of elastomer through detail reproduction and its dimensional stability (DS) after disinfection with 0.2% chloramine-T. MATERIALS AND METHODS: The elastomeric impression dental materials used in this study were polydimethylsiloxane (Oranwash L), polyvinyl siloxane (Express), polysulfide (Permlastic), and polyether (Impregum Soft). The entire press procedure was performed on a matrix in accordance with the ISO 4823. Detail reproduction was analyzed using an optical microscope (Stereozoom Microscope) over the 20-μm line with 25 mm of length at a magnification of ×4. DS was measured using an optical microscope (Scanning Tunneling Microscope) by subtracting the distance between the lines X and X' over the 20-μm line on the matrix (DM) from the distance between the lines on the impression material (DI) divided by DM and multiplied by 100 establishing the equation: DS = ([DI – DM]/DM) ×100; then, 100% was added to the results of the equation. The detail reproduction values were subsequently subjected to descriptive analysis by percentage (%), and the DS values (%) were submitted to Kolmogorov–Smirnov test, two-way ANOVA (material × disinfectant), and Tukey's test (α = 0.05). RESULTS: All elastomeric impression materials showed 100% of detail reproduction, regardless of the disinfection procedure. Polysulfide (not disinfected) and polysulfide and polydimethylsiloxane (after disinfection with 0.2% chloramine-T) showed the smaller mean values of DS. CONCLUSION: According to the stability properties analyzed, chloramine-T can be used for disinfection of elastomer molds. Medknow Publications & Media Pvt Ltd 2018 /pmc/articles/PMC6004818/ /pubmed/29988249 http://dx.doi.org/10.4103/ejd.ejd_195_17 Text en Copyright: © 2018 European Journal of Dentistry http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Guiraldo, Ricardo Danil
Berger, Sandrine Bittencourt
Punhagui, Marilia Franco
Moretto, Thais Staut
Lopes, Murilo Baena
Gonini-Júnior, Alcides
Coelho Sinhoreti, Mário Alexandre
Influence of chloramine-T disinfection on elastomeric impression stability
title Influence of chloramine-T disinfection on elastomeric impression stability
title_full Influence of chloramine-T disinfection on elastomeric impression stability
title_fullStr Influence of chloramine-T disinfection on elastomeric impression stability
title_full_unstemmed Influence of chloramine-T disinfection on elastomeric impression stability
title_short Influence of chloramine-T disinfection on elastomeric impression stability
title_sort influence of chloramine-t disinfection on elastomeric impression stability
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6004818/
https://www.ncbi.nlm.nih.gov/pubmed/29988249
http://dx.doi.org/10.4103/ejd.ejd_195_17
work_keys_str_mv AT guiraldoricardodanil influenceofchloraminetdisinfectiononelastomericimpressionstability
AT bergersandrinebittencourt influenceofchloraminetdisinfectiononelastomericimpressionstability
AT punhaguimariliafranco influenceofchloraminetdisinfectiononelastomericimpressionstability
AT morettothaisstaut influenceofchloraminetdisinfectiononelastomericimpressionstability
AT lopesmurilobaena influenceofchloraminetdisinfectiononelastomericimpressionstability
AT goninijunioralcides influenceofchloraminetdisinfectiononelastomericimpressionstability
AT coelhosinhoretimarioalexandre influenceofchloraminetdisinfectiononelastomericimpressionstability