Cargando…

Design of liver functional reserve monitor based on three-wavelength from red light to IR

BACKGROUND: The preoperative evaluation of liver functional reserve is very important to determine the excision of liver lobe for the patients with liver cancer. There already exist many effective evaluation methods, but these ones have many disadvantages such as large trauma, complicated process an...

Descripción completa

Detalles Bibliográficos
Autores principales: Ye, Fuli, Zhan, Huimiao, Shi, Guilian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: IOS Press 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6004968/
https://www.ncbi.nlm.nih.gov/pubmed/29758975
http://dx.doi.org/10.3233/THC-174843
_version_ 1783332621148749824
author Ye, Fuli
Zhan, Huimiao
Shi, Guilian
author_facet Ye, Fuli
Zhan, Huimiao
Shi, Guilian
author_sort Ye, Fuli
collection PubMed
description BACKGROUND: The preoperative evaluation of liver functional reserve is very important to determine the excision of liver lobe for the patients with liver cancer. There already exist many effective evaluation methods, but these ones have many disadvantages such as large trauma, complicated process and so on. OBJECTIVE: Therefore, it is essential to develop a fast, accurate and simple detection method of liver functional reserve for the practical application in the clinical engineering field. METHODS: According to the principle of spectrophotometry, this paper proposes a detection method of liver functional reserve based on three-wavelength from red light to infrared light (IR), in which the artery pulse, the vein pulse and the move of tissue are taken into account. RESULTS: By using photoelectric sensor technology and excreting experiment of indocyanine green, a minimally invasive, fast and simple testing equipment is designed in this paper. CONCLUSIONS: The testing result shows this equipment can greatly reduce the interference from human body and ambient, realize continuous and real-time detection of arterial degree of blood oxygen saturation and liver functional reserve.
format Online
Article
Text
id pubmed-6004968
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher IOS Press
record_format MEDLINE/PubMed
spelling pubmed-60049682018-06-25 Design of liver functional reserve monitor based on three-wavelength from red light to IR Ye, Fuli Zhan, Huimiao Shi, Guilian Technol Health Care Research Article BACKGROUND: The preoperative evaluation of liver functional reserve is very important to determine the excision of liver lobe for the patients with liver cancer. There already exist many effective evaluation methods, but these ones have many disadvantages such as large trauma, complicated process and so on. OBJECTIVE: Therefore, it is essential to develop a fast, accurate and simple detection method of liver functional reserve for the practical application in the clinical engineering field. METHODS: According to the principle of spectrophotometry, this paper proposes a detection method of liver functional reserve based on three-wavelength from red light to infrared light (IR), in which the artery pulse, the vein pulse and the move of tissue are taken into account. RESULTS: By using photoelectric sensor technology and excreting experiment of indocyanine green, a minimally invasive, fast and simple testing equipment is designed in this paper. CONCLUSIONS: The testing result shows this equipment can greatly reduce the interference from human body and ambient, realize continuous and real-time detection of arterial degree of blood oxygen saturation and liver functional reserve. IOS Press 2018-05-29 /pmc/articles/PMC6004968/ /pubmed/29758975 http://dx.doi.org/10.3233/THC-174843 Text en © 2018 – IOS Press and the authors. All rights reserved https://creativecommons.org/licenses/by-nc/4.0/ This article is published online with Open Access and distributed under the terms of the Creative Commons Attribution Non-Commercial License (CC BY-NC 4.0).
spellingShingle Research Article
Ye, Fuli
Zhan, Huimiao
Shi, Guilian
Design of liver functional reserve monitor based on three-wavelength from red light to IR
title Design of liver functional reserve monitor based on three-wavelength from red light to IR
title_full Design of liver functional reserve monitor based on three-wavelength from red light to IR
title_fullStr Design of liver functional reserve monitor based on three-wavelength from red light to IR
title_full_unstemmed Design of liver functional reserve monitor based on three-wavelength from red light to IR
title_short Design of liver functional reserve monitor based on three-wavelength from red light to IR
title_sort design of liver functional reserve monitor based on three-wavelength from red light to ir
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6004968/
https://www.ncbi.nlm.nih.gov/pubmed/29758975
http://dx.doi.org/10.3233/THC-174843
work_keys_str_mv AT yefuli designofliverfunctionalreservemonitorbasedonthreewavelengthfromredlighttoir
AT zhanhuimiao designofliverfunctionalreservemonitorbasedonthreewavelengthfromredlighttoir
AT shiguilian designofliverfunctionalreservemonitorbasedonthreewavelengthfromredlighttoir