Cargando…
Design of liver functional reserve monitor based on three-wavelength from red light to IR
BACKGROUND: The preoperative evaluation of liver functional reserve is very important to determine the excision of liver lobe for the patients with liver cancer. There already exist many effective evaluation methods, but these ones have many disadvantages such as large trauma, complicated process an...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
IOS Press
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6004968/ https://www.ncbi.nlm.nih.gov/pubmed/29758975 http://dx.doi.org/10.3233/THC-174843 |
_version_ | 1783332621148749824 |
---|---|
author | Ye, Fuli Zhan, Huimiao Shi, Guilian |
author_facet | Ye, Fuli Zhan, Huimiao Shi, Guilian |
author_sort | Ye, Fuli |
collection | PubMed |
description | BACKGROUND: The preoperative evaluation of liver functional reserve is very important to determine the excision of liver lobe for the patients with liver cancer. There already exist many effective evaluation methods, but these ones have many disadvantages such as large trauma, complicated process and so on. OBJECTIVE: Therefore, it is essential to develop a fast, accurate and simple detection method of liver functional reserve for the practical application in the clinical engineering field. METHODS: According to the principle of spectrophotometry, this paper proposes a detection method of liver functional reserve based on three-wavelength from red light to infrared light (IR), in which the artery pulse, the vein pulse and the move of tissue are taken into account. RESULTS: By using photoelectric sensor technology and excreting experiment of indocyanine green, a minimally invasive, fast and simple testing equipment is designed in this paper. CONCLUSIONS: The testing result shows this equipment can greatly reduce the interference from human body and ambient, realize continuous and real-time detection of arterial degree of blood oxygen saturation and liver functional reserve. |
format | Online Article Text |
id | pubmed-6004968 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | IOS Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-60049682018-06-25 Design of liver functional reserve monitor based on three-wavelength from red light to IR Ye, Fuli Zhan, Huimiao Shi, Guilian Technol Health Care Research Article BACKGROUND: The preoperative evaluation of liver functional reserve is very important to determine the excision of liver lobe for the patients with liver cancer. There already exist many effective evaluation methods, but these ones have many disadvantages such as large trauma, complicated process and so on. OBJECTIVE: Therefore, it is essential to develop a fast, accurate and simple detection method of liver functional reserve for the practical application in the clinical engineering field. METHODS: According to the principle of spectrophotometry, this paper proposes a detection method of liver functional reserve based on three-wavelength from red light to infrared light (IR), in which the artery pulse, the vein pulse and the move of tissue are taken into account. RESULTS: By using photoelectric sensor technology and excreting experiment of indocyanine green, a minimally invasive, fast and simple testing equipment is designed in this paper. CONCLUSIONS: The testing result shows this equipment can greatly reduce the interference from human body and ambient, realize continuous and real-time detection of arterial degree of blood oxygen saturation and liver functional reserve. IOS Press 2018-05-29 /pmc/articles/PMC6004968/ /pubmed/29758975 http://dx.doi.org/10.3233/THC-174843 Text en © 2018 – IOS Press and the authors. All rights reserved https://creativecommons.org/licenses/by-nc/4.0/ This article is published online with Open Access and distributed under the terms of the Creative Commons Attribution Non-Commercial License (CC BY-NC 4.0). |
spellingShingle | Research Article Ye, Fuli Zhan, Huimiao Shi, Guilian Design of liver functional reserve monitor based on three-wavelength from red light to IR |
title | Design of liver functional reserve monitor based on three-wavelength from red light to IR |
title_full | Design of liver functional reserve monitor based on three-wavelength from red light to IR |
title_fullStr | Design of liver functional reserve monitor based on three-wavelength from red light to IR |
title_full_unstemmed | Design of liver functional reserve monitor based on three-wavelength from red light to IR |
title_short | Design of liver functional reserve monitor based on three-wavelength from red light to IR |
title_sort | design of liver functional reserve monitor based on three-wavelength from red light to ir |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6004968/ https://www.ncbi.nlm.nih.gov/pubmed/29758975 http://dx.doi.org/10.3233/THC-174843 |
work_keys_str_mv | AT yefuli designofliverfunctionalreservemonitorbasedonthreewavelengthfromredlighttoir AT zhanhuimiao designofliverfunctionalreservemonitorbasedonthreewavelengthfromredlighttoir AT shiguilian designofliverfunctionalreservemonitorbasedonthreewavelengthfromredlighttoir |