Optimal Monochromatic Imaging of Spectral Computed Tomography Potentially Improves the Quality of Hepatic Vascular Imaging

OBJECTIVE: To investigate the efficiency of spectral computed tomography (CT) optimal monochromatic images in improving imaging quality of liver vessels. MATERIALS AND METHODS: The imaging data of 35 patients with abdominal CT angiography were retrospectively analyzed. Hepatic arteries, portal veins...

Descripción completa

Detalles Bibliográficos
Autores principales: Yin, Xiao-Ping, Gao, Bu-Lang, Li, Cai-Ying, Zhou, Huan, Zhao, Liang, Zheng, Ya-Ting, Zhao, Yong-Xia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6005939/
https://www.ncbi.nlm.nih.gov/pubmed/29962864
http://dx.doi.org/10.3348/kjr.2018.19.4.578
_version_ 1783332759146594304
author Yin, Xiao-Ping
Gao, Bu-Lang
Li, Cai-Ying
Zhou, Huan
Zhao, Liang
Zheng, Ya-Ting
Zhao, Yong-Xia
author_facet Yin, Xiao-Ping
Gao, Bu-Lang
Li, Cai-Ying
Zhou, Huan
Zhao, Liang
Zheng, Ya-Ting
Zhao, Yong-Xia
author_sort Yin, Xiao-Ping
collection PubMed
description OBJECTIVE: To investigate the efficiency of spectral computed tomography (CT) optimal monochromatic images in improving imaging quality of liver vessels. MATERIALS AND METHODS: The imaging data of 35 patients with abdominal CT angiography were retrospectively analyzed. Hepatic arteries, portal veins, and hepatic veins were reconstructed with mixed energy (quality check, QC), 70 keV and optimal monochromatic mode. Comparative parameters were analyzed including CT value, image noise (IN), contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and subjective qualitative analysis. RESULTS: The optimal monochromatic value for assessment of the common hepatic artery, portal vein, and hepatic vein ranged between 49 keV and 53 keV, with a mean of 51 keV. There were statistically significant differences (p < 0.001) among the optimal monochromatic, 70 keV and QC images with regards to the hepatic vascular CT value, IN, CNR, SNR, and subjective qualitative score. CNR of the common hepatic artery in the optimal monochromatic, 70 keV and QC groups was 24.6 ± 10.9, 18.1 ± 8.3, and 11.6 ± 4.6, respectively (p < 0.001) with subjective scores of 4.7 ± 0.2, 4.0 ± 0.3, and 3.6 ± 0.4, respectively (p < 0.001). CNR of the hepatic portal vein was 6.9 ± 2.7, 4.3 ± 1.9, and 3.0 ± 2.1, respectively (p < 0.001) with subjective scores of 4.5 ± 0.3, 3.9 ± 0.4, and 3.3 ± 0.3, respectively (p < 0.001). CNR of the hepatic vein was 5.7 ± 2.3, 4.2 ± 1.9, and 2.7 ± 1.4, respectively with subjective scores of 4.3 ± 0.3, 3.8 ± 0.4, and 3.2 ± 0.3, respectively (p < 0.001). CONCLUSION: Optimal monochromatic images can lead to improvement in the imaging parameters and optimization of the image quality of the common hepatic artery, hepatic portal vein and hepatic vein compared with conventional mixed kV and with 70 keV datasets.
format Online
Article
Text
id pubmed-6005939
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-60059392018-07-01 Optimal Monochromatic Imaging of Spectral Computed Tomography Potentially Improves the Quality of Hepatic Vascular Imaging Yin, Xiao-Ping Gao, Bu-Lang Li, Cai-Ying Zhou, Huan Zhao, Liang Zheng, Ya-Ting Zhao, Yong-Xia Korean J Radiol Gastrointestinal Imaging OBJECTIVE: To investigate the efficiency of spectral computed tomography (CT) optimal monochromatic images in improving imaging quality of liver vessels. MATERIALS AND METHODS: The imaging data of 35 patients with abdominal CT angiography were retrospectively analyzed. Hepatic arteries, portal veins, and hepatic veins were reconstructed with mixed energy (quality check, QC), 70 keV and optimal monochromatic mode. Comparative parameters were analyzed including CT value, image noise (IN), contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and subjective qualitative analysis. RESULTS: The optimal monochromatic value for assessment of the common hepatic artery, portal vein, and hepatic vein ranged between 49 keV and 53 keV, with a mean of 51 keV. There were statistically significant differences (p < 0.001) among the optimal monochromatic, 70 keV and QC images with regards to the hepatic vascular CT value, IN, CNR, SNR, and subjective qualitative score. CNR of the common hepatic artery in the optimal monochromatic, 70 keV and QC groups was 24.6 ± 10.9, 18.1 ± 8.3, and 11.6 ± 4.6, respectively (p < 0.001) with subjective scores of 4.7 ± 0.2, 4.0 ± 0.3, and 3.6 ± 0.4, respectively (p < 0.001). CNR of the hepatic portal vein was 6.9 ± 2.7, 4.3 ± 1.9, and 3.0 ± 2.1, respectively (p < 0.001) with subjective scores of 4.5 ± 0.3, 3.9 ± 0.4, and 3.3 ± 0.3, respectively (p < 0.001). CNR of the hepatic vein was 5.7 ± 2.3, 4.2 ± 1.9, and 2.7 ± 1.4, respectively with subjective scores of 4.3 ± 0.3, 3.8 ± 0.4, and 3.2 ± 0.3, respectively (p < 0.001). CONCLUSION: Optimal monochromatic images can lead to improvement in the imaging parameters and optimization of the image quality of the common hepatic artery, hepatic portal vein and hepatic vein compared with conventional mixed kV and with 70 keV datasets. The Korean Society of Radiology 2018 2018-06-14 /pmc/articles/PMC6005939/ /pubmed/29962864 http://dx.doi.org/10.3348/kjr.2018.19.4.578 Text en Copyright © 2018 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Gastrointestinal Imaging
Yin, Xiao-Ping
Gao, Bu-Lang
Li, Cai-Ying
Zhou, Huan
Zhao, Liang
Zheng, Ya-Ting
Zhao, Yong-Xia
Optimal Monochromatic Imaging of Spectral Computed Tomography Potentially Improves the Quality of Hepatic Vascular Imaging
title Optimal Monochromatic Imaging of Spectral Computed Tomography Potentially Improves the Quality of Hepatic Vascular Imaging
title_full Optimal Monochromatic Imaging of Spectral Computed Tomography Potentially Improves the Quality of Hepatic Vascular Imaging
title_fullStr Optimal Monochromatic Imaging of Spectral Computed Tomography Potentially Improves the Quality of Hepatic Vascular Imaging
title_full_unstemmed Optimal Monochromatic Imaging of Spectral Computed Tomography Potentially Improves the Quality of Hepatic Vascular Imaging
title_short Optimal Monochromatic Imaging of Spectral Computed Tomography Potentially Improves the Quality of Hepatic Vascular Imaging
title_sort optimal monochromatic imaging of spectral computed tomography potentially improves the quality of hepatic vascular imaging
topic Gastrointestinal Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6005939/
https://www.ncbi.nlm.nih.gov/pubmed/29962864
http://dx.doi.org/10.3348/kjr.2018.19.4.578
work_keys_str_mv AT yinxiaoping optimalmonochromaticimagingofspectralcomputedtomographypotentiallyimprovesthequalityofhepaticvascularimaging
AT gaobulang optimalmonochromaticimagingofspectralcomputedtomographypotentiallyimprovesthequalityofhepaticvascularimaging
AT licaiying optimalmonochromaticimagingofspectralcomputedtomographypotentiallyimprovesthequalityofhepaticvascularimaging
AT zhouhuan optimalmonochromaticimagingofspectralcomputedtomographypotentiallyimprovesthequalityofhepaticvascularimaging
AT zhaoliang optimalmonochromaticimagingofspectralcomputedtomographypotentiallyimprovesthequalityofhepaticvascularimaging
AT zhengyating optimalmonochromaticimagingofspectralcomputedtomographypotentiallyimprovesthequalityofhepaticvascularimaging
AT zhaoyongxia optimalmonochromaticimagingofspectralcomputedtomographypotentiallyimprovesthequalityofhepaticvascularimaging