Cargando…

Biomechanical study of three kinds of internal fixation for the treatment of sacroiliac joint disruption using biomechanical test and finite element analysis

BACKGROUND: To compare the stability of sacroiliac joint disruption fixed with three kinds of internal fixation using both biomechanical test and finite element analysis. METHODS: Five embalmed specimens of an adult were used. The symphysis pubis rupture and left sacroiliac joint disruption were cre...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Tao, Ren, Xuejiao, Cui, Yunwei, Cheng, Xiaodong, Peng, Shuo, Hou, Zhiyong, Han, Yongtai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6006595/
https://www.ncbi.nlm.nih.gov/pubmed/29914519
http://dx.doi.org/10.1186/s13018-018-0858-2
_version_ 1783332867808428032
author Wu, Tao
Ren, Xuejiao
Cui, Yunwei
Cheng, Xiaodong
Peng, Shuo
Hou, Zhiyong
Han, Yongtai
author_facet Wu, Tao
Ren, Xuejiao
Cui, Yunwei
Cheng, Xiaodong
Peng, Shuo
Hou, Zhiyong
Han, Yongtai
author_sort Wu, Tao
collection PubMed
description BACKGROUND: To compare the stability of sacroiliac joint disruption fixed with three kinds of internal fixation using both biomechanical test and finite element analysis. METHODS: Five embalmed specimens of an adult were used. The symphysis pubis rupture and left sacroiliac joint disruption were created. The symphysis pubis was stabilized with a five-hole plate. The sacroiliac joint disruption was fixed with three kinds of internal fixation in a randomized design. Displacements of the whole specimen and shifts in the gap were recorded. Three-dimensional finite element models of the pelvis, the pelvis with symphysis pubis rupture and left sacroiliac joint disruption, and three kinds of internal fixation techniques were created and analyzed. RESULTS: Under the vertical load, the displacements and shifts in the gap of the pelvis fixed with minimally invasive adjustable plate (MIAP) combined with one iliosacral (IS) screw were the smallest, and the average displacements of the pelvis fixed with an anterior plate were the largest one. The differences among them were significant. In finite element analysis and MIAP combined with one IS screw fixation showed relatively best fixation stability and lowest risks of implant failure than two IS screws fixation and anterior plate fixation. CONCLUSION: The stability of sacroiliac joint disruption fixed with MIAP combined with one IS screw is better than that fixed with two IS screws and anterior plate under vertical load.
format Online
Article
Text
id pubmed-6006595
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-60065952018-06-26 Biomechanical study of three kinds of internal fixation for the treatment of sacroiliac joint disruption using biomechanical test and finite element analysis Wu, Tao Ren, Xuejiao Cui, Yunwei Cheng, Xiaodong Peng, Shuo Hou, Zhiyong Han, Yongtai J Orthop Surg Res Research Article BACKGROUND: To compare the stability of sacroiliac joint disruption fixed with three kinds of internal fixation using both biomechanical test and finite element analysis. METHODS: Five embalmed specimens of an adult were used. The symphysis pubis rupture and left sacroiliac joint disruption were created. The symphysis pubis was stabilized with a five-hole plate. The sacroiliac joint disruption was fixed with three kinds of internal fixation in a randomized design. Displacements of the whole specimen and shifts in the gap were recorded. Three-dimensional finite element models of the pelvis, the pelvis with symphysis pubis rupture and left sacroiliac joint disruption, and three kinds of internal fixation techniques were created and analyzed. RESULTS: Under the vertical load, the displacements and shifts in the gap of the pelvis fixed with minimally invasive adjustable plate (MIAP) combined with one iliosacral (IS) screw were the smallest, and the average displacements of the pelvis fixed with an anterior plate were the largest one. The differences among them were significant. In finite element analysis and MIAP combined with one IS screw fixation showed relatively best fixation stability and lowest risks of implant failure than two IS screws fixation and anterior plate fixation. CONCLUSION: The stability of sacroiliac joint disruption fixed with MIAP combined with one IS screw is better than that fixed with two IS screws and anterior plate under vertical load. BioMed Central 2018-06-19 /pmc/articles/PMC6006595/ /pubmed/29914519 http://dx.doi.org/10.1186/s13018-018-0858-2 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Wu, Tao
Ren, Xuejiao
Cui, Yunwei
Cheng, Xiaodong
Peng, Shuo
Hou, Zhiyong
Han, Yongtai
Biomechanical study of three kinds of internal fixation for the treatment of sacroiliac joint disruption using biomechanical test and finite element analysis
title Biomechanical study of three kinds of internal fixation for the treatment of sacroiliac joint disruption using biomechanical test and finite element analysis
title_full Biomechanical study of three kinds of internal fixation for the treatment of sacroiliac joint disruption using biomechanical test and finite element analysis
title_fullStr Biomechanical study of three kinds of internal fixation for the treatment of sacroiliac joint disruption using biomechanical test and finite element analysis
title_full_unstemmed Biomechanical study of three kinds of internal fixation for the treatment of sacroiliac joint disruption using biomechanical test and finite element analysis
title_short Biomechanical study of three kinds of internal fixation for the treatment of sacroiliac joint disruption using biomechanical test and finite element analysis
title_sort biomechanical study of three kinds of internal fixation for the treatment of sacroiliac joint disruption using biomechanical test and finite element analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6006595/
https://www.ncbi.nlm.nih.gov/pubmed/29914519
http://dx.doi.org/10.1186/s13018-018-0858-2
work_keys_str_mv AT wutao biomechanicalstudyofthreekindsofinternalfixationforthetreatmentofsacroiliacjointdisruptionusingbiomechanicaltestandfiniteelementanalysis
AT renxuejiao biomechanicalstudyofthreekindsofinternalfixationforthetreatmentofsacroiliacjointdisruptionusingbiomechanicaltestandfiniteelementanalysis
AT cuiyunwei biomechanicalstudyofthreekindsofinternalfixationforthetreatmentofsacroiliacjointdisruptionusingbiomechanicaltestandfiniteelementanalysis
AT chengxiaodong biomechanicalstudyofthreekindsofinternalfixationforthetreatmentofsacroiliacjointdisruptionusingbiomechanicaltestandfiniteelementanalysis
AT pengshuo biomechanicalstudyofthreekindsofinternalfixationforthetreatmentofsacroiliacjointdisruptionusingbiomechanicaltestandfiniteelementanalysis
AT houzhiyong biomechanicalstudyofthreekindsofinternalfixationforthetreatmentofsacroiliacjointdisruptionusingbiomechanicaltestandfiniteelementanalysis
AT hanyongtai biomechanicalstudyofthreekindsofinternalfixationforthetreatmentofsacroiliacjointdisruptionusingbiomechanicaltestandfiniteelementanalysis