BACKGROUND: Salivary melatonin levels have been analyzed in many research fields, including physiological anthropology. Although various devices have been utilized for saliva collection, cotton swabs are among the most common. However, previous studies have reported that cotton swabs may interfere w...

Descripción completa

Detalles Bibliográficos
Autores principales: Kozaki, Tomoaki, Hidaka, Yuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6006933/
https://www.ncbi.nlm.nih.gov/pubmed/29914553
http://dx.doi.org/10.1186/s40101-018-0178-6
_version_ 1783332944625008640
author Kozaki, Tomoaki
Hidaka, Yuki
author_facet Kozaki, Tomoaki
Hidaka, Yuki
author_sort Kozaki, Tomoaki
collection PubMed
description BACKGROUND: Salivary melatonin levels have been analyzed in many research fields, including physiological anthropology. Although various devices have been utilized for saliva collection, cotton swabs are among the most common. However, previous studies have reported that cotton swabs may interfere with melatonin assay results, whereas synthetic swabs may not. These studies compared only mean melatonin levels between passive and synthetic-polymer swab collection methods but did not evaluate relative and proportional biases. Our study examines the effects of using swabs made of materials other than cotton, such as polypropylene–polyethylene polymer, on salivary melatonin assay results using a Bland–Altman (BA) plot. The effects of the saliva collection method were analyzed using two concentrations of melatonin, lower (< 6 pg/ml) and higher (> 6 pg/ml), because the threshold of dim light melatonin onset was lower than 6 pg/ml in many studies. RESULTS: Differences detected between passive and polypropylene–polyethylene polymer swab methods of saliva collection were not significant in both lower (< 6 pg/ml) and higher (> 6 pg/ml) melatonin levels detected. All correlations between the collection methods were significant, and 95% confidence intervals for differences in melatonin levels in all samples detected using passive and non-cotton swab saliva collection methods included zero in the BA plots. Averages and differences between non-cotton and passive saliva collection obtained from the BA plots were not significantly correlated at lower and higher melatonin levels. CONCLUSIONS: Our findings demonstrate that swabbing methods, including the use of polypropylene–polyethylene polymer, do not affect salivary melatonin assay results. Therefore, the authors suggest that polypropylene–polyethylene polymer swab methods are appropriate for the assessment of dim light melatonin onset and dose response of the circadian system to light.
format Online
Article
Text
id pubmed-6006933
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-60069332018-06-26 Non-cotton swab sample collection may not affect salivary melatonin assay results Kozaki, Tomoaki Hidaka, Yuki J Physiol Anthropol Methodology Article BACKGROUND: Salivary melatonin levels have been analyzed in many research fields, including physiological anthropology. Although various devices have been utilized for saliva collection, cotton swabs are among the most common. However, previous studies have reported that cotton swabs may interfere with melatonin assay results, whereas synthetic swabs may not. These studies compared only mean melatonin levels between passive and synthetic-polymer swab collection methods but did not evaluate relative and proportional biases. Our study examines the effects of using swabs made of materials other than cotton, such as polypropylene–polyethylene polymer, on salivary melatonin assay results using a Bland–Altman (BA) plot. The effects of the saliva collection method were analyzed using two concentrations of melatonin, lower (< 6 pg/ml) and higher (> 6 pg/ml), because the threshold of dim light melatonin onset was lower than 6 pg/ml in many studies. RESULTS: Differences detected between passive and polypropylene–polyethylene polymer swab methods of saliva collection were not significant in both lower (< 6 pg/ml) and higher (> 6 pg/ml) melatonin levels detected. All correlations between the collection methods were significant, and 95% confidence intervals for differences in melatonin levels in all samples detected using passive and non-cotton swab saliva collection methods included zero in the BA plots. Averages and differences between non-cotton and passive saliva collection obtained from the BA plots were not significantly correlated at lower and higher melatonin levels. CONCLUSIONS: Our findings demonstrate that swabbing methods, including the use of polypropylene–polyethylene polymer, do not affect salivary melatonin assay results. Therefore, the authors suggest that polypropylene–polyethylene polymer swab methods are appropriate for the assessment of dim light melatonin onset and dose response of the circadian system to light. BioMed Central 2018-06-18 /pmc/articles/PMC6006933/ /pubmed/29914553 http://dx.doi.org/10.1186/s40101-018-0178-6 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Methodology Article
Kozaki, Tomoaki
Hidaka, Yuki
Non-cotton swab sample collection may not affect salivary melatonin assay results
title Non-cotton swab sample collection may not affect salivary melatonin assay results
title_full Non-cotton swab sample collection may not affect salivary melatonin assay results
title_fullStr Non-cotton swab sample collection may not affect salivary melatonin assay results
title_full_unstemmed Non-cotton swab sample collection may not affect salivary melatonin assay results
title_short Non-cotton swab sample collection may not affect salivary melatonin assay results
title_sort non-cotton swab sample collection may not affect salivary melatonin assay results
topic Methodology Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6006933/
https://www.ncbi.nlm.nih.gov/pubmed/29914553
http://dx.doi.org/10.1186/s40101-018-0178-6
work_keys_str_mv AT kozakitomoaki noncottonswabsamplecollectionmaynotaffectsalivarymelatoninassayresults
AT hidakayuki noncottonswabsamplecollectionmaynotaffectsalivarymelatoninassayresults