Cargando…

Endovascular stent-induced alterations in host artery mechanical environments and their roles in stent restenosis and late thrombosis

Cardiovascular stent restenosis remains a major challenge in interventional treatment of cardiovascular occlusive disease. Although the changes in arterial mechanical environment due to stent implantation are the main causes of the initiation of restenosis and thrombosis, the mechanisms that cause t...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Jinxuan, Jin, Xuepu, Huang, Yuhua, Ran, Xiaolin, Luo, Desha, Yang, Dongchuan, Jia, Dongyu, Zhang, Kang, Tong, Jianhua, Deng, Xiaoyan, Wang, Guixue
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6007795/
https://www.ncbi.nlm.nih.gov/pubmed/29942650
http://dx.doi.org/10.1093/rb/rby006
_version_ 1783333097017704448
author Wang, Jinxuan
Jin, Xuepu
Huang, Yuhua
Ran, Xiaolin
Luo, Desha
Yang, Dongchuan
Jia, Dongyu
Zhang, Kang
Tong, Jianhua
Deng, Xiaoyan
Wang, Guixue
author_facet Wang, Jinxuan
Jin, Xuepu
Huang, Yuhua
Ran, Xiaolin
Luo, Desha
Yang, Dongchuan
Jia, Dongyu
Zhang, Kang
Tong, Jianhua
Deng, Xiaoyan
Wang, Guixue
author_sort Wang, Jinxuan
collection PubMed
description Cardiovascular stent restenosis remains a major challenge in interventional treatment of cardiovascular occlusive disease. Although the changes in arterial mechanical environment due to stent implantation are the main causes of the initiation of restenosis and thrombosis, the mechanisms that cause this initiation are still not fully understood. In this article, we reviewed the studies on the issue of stent-induced alterations in arterial mechanical environment and discussed their roles in stent restenosis and late thrombosis from three aspects: (i) the interaction of the stent with host blood vessel, involve the response of vascular wall, the mechanism of mechanical signal transmission, the process of re-endothelialization and late thrombosis; (ii) the changes of hemodynamics in the lumen of the vascular segment and (iii) the changes of mechanical microenvironment within the vascular segment wall due to stent implantation. This review has summarized and analyzed current work in order to better solve the two main problems after stent implantation, namely in stent restenosis and late thrombosis, meanwhile propose the deficiencies of current work for future reference.
format Online
Article
Text
id pubmed-6007795
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-60077952018-06-25 Endovascular stent-induced alterations in host artery mechanical environments and their roles in stent restenosis and late thrombosis Wang, Jinxuan Jin, Xuepu Huang, Yuhua Ran, Xiaolin Luo, Desha Yang, Dongchuan Jia, Dongyu Zhang, Kang Tong, Jianhua Deng, Xiaoyan Wang, Guixue Regen Biomater Review Cardiovascular stent restenosis remains a major challenge in interventional treatment of cardiovascular occlusive disease. Although the changes in arterial mechanical environment due to stent implantation are the main causes of the initiation of restenosis and thrombosis, the mechanisms that cause this initiation are still not fully understood. In this article, we reviewed the studies on the issue of stent-induced alterations in arterial mechanical environment and discussed their roles in stent restenosis and late thrombosis from three aspects: (i) the interaction of the stent with host blood vessel, involve the response of vascular wall, the mechanism of mechanical signal transmission, the process of re-endothelialization and late thrombosis; (ii) the changes of hemodynamics in the lumen of the vascular segment and (iii) the changes of mechanical microenvironment within the vascular segment wall due to stent implantation. This review has summarized and analyzed current work in order to better solve the two main problems after stent implantation, namely in stent restenosis and late thrombosis, meanwhile propose the deficiencies of current work for future reference. Oxford University Press 2018-06 2018-05-02 /pmc/articles/PMC6007795/ /pubmed/29942650 http://dx.doi.org/10.1093/rb/rby006 Text en © The Author(s) 2018. Published by Oxford University Press. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review
Wang, Jinxuan
Jin, Xuepu
Huang, Yuhua
Ran, Xiaolin
Luo, Desha
Yang, Dongchuan
Jia, Dongyu
Zhang, Kang
Tong, Jianhua
Deng, Xiaoyan
Wang, Guixue
Endovascular stent-induced alterations in host artery mechanical environments and their roles in stent restenosis and late thrombosis
title Endovascular stent-induced alterations in host artery mechanical environments and their roles in stent restenosis and late thrombosis
title_full Endovascular stent-induced alterations in host artery mechanical environments and their roles in stent restenosis and late thrombosis
title_fullStr Endovascular stent-induced alterations in host artery mechanical environments and their roles in stent restenosis and late thrombosis
title_full_unstemmed Endovascular stent-induced alterations in host artery mechanical environments and their roles in stent restenosis and late thrombosis
title_short Endovascular stent-induced alterations in host artery mechanical environments and their roles in stent restenosis and late thrombosis
title_sort endovascular stent-induced alterations in host artery mechanical environments and their roles in stent restenosis and late thrombosis
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6007795/
https://www.ncbi.nlm.nih.gov/pubmed/29942650
http://dx.doi.org/10.1093/rb/rby006
work_keys_str_mv AT wangjinxuan endovascularstentinducedalterationsinhostarterymechanicalenvironmentsandtheirrolesinstentrestenosisandlatethrombosis
AT jinxuepu endovascularstentinducedalterationsinhostarterymechanicalenvironmentsandtheirrolesinstentrestenosisandlatethrombosis
AT huangyuhua endovascularstentinducedalterationsinhostarterymechanicalenvironmentsandtheirrolesinstentrestenosisandlatethrombosis
AT ranxiaolin endovascularstentinducedalterationsinhostarterymechanicalenvironmentsandtheirrolesinstentrestenosisandlatethrombosis
AT luodesha endovascularstentinducedalterationsinhostarterymechanicalenvironmentsandtheirrolesinstentrestenosisandlatethrombosis
AT yangdongchuan endovascularstentinducedalterationsinhostarterymechanicalenvironmentsandtheirrolesinstentrestenosisandlatethrombosis
AT jiadongyu endovascularstentinducedalterationsinhostarterymechanicalenvironmentsandtheirrolesinstentrestenosisandlatethrombosis
AT zhangkang endovascularstentinducedalterationsinhostarterymechanicalenvironmentsandtheirrolesinstentrestenosisandlatethrombosis
AT tongjianhua endovascularstentinducedalterationsinhostarterymechanicalenvironmentsandtheirrolesinstentrestenosisandlatethrombosis
AT dengxiaoyan endovascularstentinducedalterationsinhostarterymechanicalenvironmentsandtheirrolesinstentrestenosisandlatethrombosis
AT wangguixue endovascularstentinducedalterationsinhostarterymechanicalenvironmentsandtheirrolesinstentrestenosisandlatethrombosis