Cargando…
Effects of preoperative plasma exchange therapy with albumin replacement fluid on blood coagulation in patients undergoing ABO-incompatible living-donor kidney transplantation using rotational thromboelastometry
BACKGROUND: ABO-incompatible living-donor kidney transplantation (LDKT) requires immunotherapy and plasma exchange therapy (PEX). PEX with albumin replacement fluid reportedly decreases fibrinogen levels. However, no reports have described the effects of PEX with albumin replacement fluid on blood c...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6008919/ https://www.ncbi.nlm.nih.gov/pubmed/29921231 http://dx.doi.org/10.1186/s12871-018-0536-2 |
_version_ | 1783333277612900352 |
---|---|
author | Shirozu, Kazuhiro Fujimura, Naoyuki Karashima, Yuji Ikeda, Mizuko Kitada, Hidehisa Okabe, Yasuhiro Kurihara, Kei Henzan, Tomoko Hoka, Sumio |
author_facet | Shirozu, Kazuhiro Fujimura, Naoyuki Karashima, Yuji Ikeda, Mizuko Kitada, Hidehisa Okabe, Yasuhiro Kurihara, Kei Henzan, Tomoko Hoka, Sumio |
author_sort | Shirozu, Kazuhiro |
collection | PubMed |
description | BACKGROUND: ABO-incompatible living-donor kidney transplantation (LDKT) requires immunotherapy and plasma exchange therapy (PEX). PEX with albumin replacement fluid reportedly decreases fibrinogen levels. However, no reports have described the effects of PEX with albumin replacement fluid on blood coagulation parameters and blood loss during the perioperative period. Therefore, we investigated the effects of preoperative PEX on blood coagulation parameters and blood loss during the perioperative period in patients undergoing ABO-incompatible LDKT as measured by rotational thromboelastometry (ROTEM®). METHODS: Twenty-eight patients undergoing LDKT were divided into the PEX group (ABO incompatible with PEX, n = 13) and non-PEX group (ABO compatible without PEX, n = 15). ROTEM® parameters, standard laboratory test parameters, bleeding volume, and transfusion volume were compared between PEX and non-PEX group. MCE(platelet), which represents platelet contribution to clot strength and where “MCE” stands for maximum clot elasticity, was calculated from the difference in MCE between EXTEM and FIBTEM. RESULTS: The bleeding volume during surgery and the intensive care unit (ICU) stay was significantly higher in the PEX than non-PEX group (p < 0.01). Maximum clot firmness (MCF) of EXTEM (MCF(EXTEM)), MCF(FIBTEM), and MCE(platelet) was significantly lower in the PEX than non-PEX group (p < 0.01). In the PEX group, the bleeding volume during surgery was very strongly correlated with the baseline MCF(EXTEM) and MCE(platelet), and the bleeding volume during the ICU stay was strongly correlated with the postoperative MCF(EXTEM) and MCE(platelet). CONCLUSIONS: These results suggest that the increased blood loss in the PEX group during surgery and the ICU stay was associated with decreased platelet contribution to clot strength as measured by ROTEM®. TRIAL REGISTRATION: UMIN-Clinical Trial Registry UMIN000018355. Registered 21 July 2015. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12871-018-0536-2) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-6008919 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-60089192018-06-26 Effects of preoperative plasma exchange therapy with albumin replacement fluid on blood coagulation in patients undergoing ABO-incompatible living-donor kidney transplantation using rotational thromboelastometry Shirozu, Kazuhiro Fujimura, Naoyuki Karashima, Yuji Ikeda, Mizuko Kitada, Hidehisa Okabe, Yasuhiro Kurihara, Kei Henzan, Tomoko Hoka, Sumio BMC Anesthesiol Research Article BACKGROUND: ABO-incompatible living-donor kidney transplantation (LDKT) requires immunotherapy and plasma exchange therapy (PEX). PEX with albumin replacement fluid reportedly decreases fibrinogen levels. However, no reports have described the effects of PEX with albumin replacement fluid on blood coagulation parameters and blood loss during the perioperative period. Therefore, we investigated the effects of preoperative PEX on blood coagulation parameters and blood loss during the perioperative period in patients undergoing ABO-incompatible LDKT as measured by rotational thromboelastometry (ROTEM®). METHODS: Twenty-eight patients undergoing LDKT were divided into the PEX group (ABO incompatible with PEX, n = 13) and non-PEX group (ABO compatible without PEX, n = 15). ROTEM® parameters, standard laboratory test parameters, bleeding volume, and transfusion volume were compared between PEX and non-PEX group. MCE(platelet), which represents platelet contribution to clot strength and where “MCE” stands for maximum clot elasticity, was calculated from the difference in MCE between EXTEM and FIBTEM. RESULTS: The bleeding volume during surgery and the intensive care unit (ICU) stay was significantly higher in the PEX than non-PEX group (p < 0.01). Maximum clot firmness (MCF) of EXTEM (MCF(EXTEM)), MCF(FIBTEM), and MCE(platelet) was significantly lower in the PEX than non-PEX group (p < 0.01). In the PEX group, the bleeding volume during surgery was very strongly correlated with the baseline MCF(EXTEM) and MCE(platelet), and the bleeding volume during the ICU stay was strongly correlated with the postoperative MCF(EXTEM) and MCE(platelet). CONCLUSIONS: These results suggest that the increased blood loss in the PEX group during surgery and the ICU stay was associated with decreased platelet contribution to clot strength as measured by ROTEM®. TRIAL REGISTRATION: UMIN-Clinical Trial Registry UMIN000018355. Registered 21 July 2015. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12871-018-0536-2) contains supplementary material, which is available to authorized users. BioMed Central 2018-06-19 /pmc/articles/PMC6008919/ /pubmed/29921231 http://dx.doi.org/10.1186/s12871-018-0536-2 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Shirozu, Kazuhiro Fujimura, Naoyuki Karashima, Yuji Ikeda, Mizuko Kitada, Hidehisa Okabe, Yasuhiro Kurihara, Kei Henzan, Tomoko Hoka, Sumio Effects of preoperative plasma exchange therapy with albumin replacement fluid on blood coagulation in patients undergoing ABO-incompatible living-donor kidney transplantation using rotational thromboelastometry |
title | Effects of preoperative plasma exchange therapy with albumin replacement fluid on blood coagulation in patients undergoing ABO-incompatible living-donor kidney transplantation using rotational thromboelastometry |
title_full | Effects of preoperative plasma exchange therapy with albumin replacement fluid on blood coagulation in patients undergoing ABO-incompatible living-donor kidney transplantation using rotational thromboelastometry |
title_fullStr | Effects of preoperative plasma exchange therapy with albumin replacement fluid on blood coagulation in patients undergoing ABO-incompatible living-donor kidney transplantation using rotational thromboelastometry |
title_full_unstemmed | Effects of preoperative plasma exchange therapy with albumin replacement fluid on blood coagulation in patients undergoing ABO-incompatible living-donor kidney transplantation using rotational thromboelastometry |
title_short | Effects of preoperative plasma exchange therapy with albumin replacement fluid on blood coagulation in patients undergoing ABO-incompatible living-donor kidney transplantation using rotational thromboelastometry |
title_sort | effects of preoperative plasma exchange therapy with albumin replacement fluid on blood coagulation in patients undergoing abo-incompatible living-donor kidney transplantation using rotational thromboelastometry |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6008919/ https://www.ncbi.nlm.nih.gov/pubmed/29921231 http://dx.doi.org/10.1186/s12871-018-0536-2 |
work_keys_str_mv | AT shirozukazuhiro effectsofpreoperativeplasmaexchangetherapywithalbuminreplacementfluidonbloodcoagulationinpatientsundergoingaboincompatiblelivingdonorkidneytransplantationusingrotationalthromboelastometry AT fujimuranaoyuki effectsofpreoperativeplasmaexchangetherapywithalbuminreplacementfluidonbloodcoagulationinpatientsundergoingaboincompatiblelivingdonorkidneytransplantationusingrotationalthromboelastometry AT karashimayuji effectsofpreoperativeplasmaexchangetherapywithalbuminreplacementfluidonbloodcoagulationinpatientsundergoingaboincompatiblelivingdonorkidneytransplantationusingrotationalthromboelastometry AT ikedamizuko effectsofpreoperativeplasmaexchangetherapywithalbuminreplacementfluidonbloodcoagulationinpatientsundergoingaboincompatiblelivingdonorkidneytransplantationusingrotationalthromboelastometry AT kitadahidehisa effectsofpreoperativeplasmaexchangetherapywithalbuminreplacementfluidonbloodcoagulationinpatientsundergoingaboincompatiblelivingdonorkidneytransplantationusingrotationalthromboelastometry AT okabeyasuhiro effectsofpreoperativeplasmaexchangetherapywithalbuminreplacementfluidonbloodcoagulationinpatientsundergoingaboincompatiblelivingdonorkidneytransplantationusingrotationalthromboelastometry AT kuriharakei effectsofpreoperativeplasmaexchangetherapywithalbuminreplacementfluidonbloodcoagulationinpatientsundergoingaboincompatiblelivingdonorkidneytransplantationusingrotationalthromboelastometry AT henzantomoko effectsofpreoperativeplasmaexchangetherapywithalbuminreplacementfluidonbloodcoagulationinpatientsundergoingaboincompatiblelivingdonorkidneytransplantationusingrotationalthromboelastometry AT hokasumio effectsofpreoperativeplasmaexchangetherapywithalbuminreplacementfluidonbloodcoagulationinpatientsundergoingaboincompatiblelivingdonorkidneytransplantationusingrotationalthromboelastometry |