Cargando…

Accuracy, reproducibility and costs of different laboratory assays for the monitoring of unfractionated heparin in clinical practice: a prospective evaluation study and survey among Swiss institutions

OBJECTIVES: To investigate the accuracy, reproducibility and costs of different laboratory assays for the monitoring of unfractionated heparin (UFH) in clinical practice and to study test utilisation in Switzerland. DESIGN: Prospective evaluation study and survey among Swiss hospitals and laboratori...

Descripción completa

Detalles Bibliográficos
Autores principales: Bürki, Susanne, Brand, Béatrice, Escher, Robert, Wuillemin, Walter A, Nagler, Michael
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6009553/
https://www.ncbi.nlm.nih.gov/pubmed/29886450
http://dx.doi.org/10.1136/bmjopen-2018-022943
_version_ 1783333412581408768
author Bürki, Susanne
Brand, Béatrice
Escher, Robert
Wuillemin, Walter A
Nagler, Michael
author_facet Bürki, Susanne
Brand, Béatrice
Escher, Robert
Wuillemin, Walter A
Nagler, Michael
author_sort Bürki, Susanne
collection PubMed
description OBJECTIVES: To investigate the accuracy, reproducibility and costs of different laboratory assays for the monitoring of unfractionated heparin (UFH) in clinical practice and to study test utilisation in Switzerland. DESIGN: Prospective evaluation study and survey among Swiss hospitals and laboratories. SETTING: Secondary care hospital in rural Switzerland (evaluation study); all Swiss hospitals and laboratories (survey). PARTICIPANTS: All consecutive patients, monitored for treatment with UFH during two time periods, were included (May to July 2014 and January to February 2015; n=254). OUTCOME MEASURES: Results of activated partial thromboplastin time (aPTT), thrombin time (TT), prothrombinase-induced clotting time (PiCT) and anti-Xa activity with respect to UFH concentration RESULTS: Spearman’s correlation coefficient (r(s)) with regard to anti-Xa activity was 0.68 (95% CI 0.60 to 0.75) for aPTT, 0.79 (0.69 to 0.86) for TT and 0.94 (0.93 to 0.95) for PiCT. The correlation (r(s)) between anti-Xa activity and heparin concentration as determined by spiking plasma samples was 1.0 (1.0 to 1.0). The coefficient of variation was at most 5% for PiCT and anti-Xa activity (within-run as well as day-to-day variability). The total costs per test in Swiss Francs (SFr) were SFr23.40 for aPTT, SFr33.30 for TT, SFr15.70 for PiCT and SFr24.15 for anti-Xa activity. The various tests were employed in Swiss institutions with the following frequencies: aPTT 53.2%, TT 21.6%, anti-Xa activity 7.2%, PiCT 1.4%; 16.6% of hospitals performed more than one test. CONCLUSIONS: The accuracy and reproducibility of PiCT and anti-Xa activity for monitoring of UFH was superior, and analytical costs were equivalent to or lower than aPTT and TT.
format Online
Article
Text
id pubmed-6009553
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-60095532018-06-25 Accuracy, reproducibility and costs of different laboratory assays for the monitoring of unfractionated heparin in clinical practice: a prospective evaluation study and survey among Swiss institutions Bürki, Susanne Brand, Béatrice Escher, Robert Wuillemin, Walter A Nagler, Michael BMJ Open Cardiovascular Medicine OBJECTIVES: To investigate the accuracy, reproducibility and costs of different laboratory assays for the monitoring of unfractionated heparin (UFH) in clinical practice and to study test utilisation in Switzerland. DESIGN: Prospective evaluation study and survey among Swiss hospitals and laboratories. SETTING: Secondary care hospital in rural Switzerland (evaluation study); all Swiss hospitals and laboratories (survey). PARTICIPANTS: All consecutive patients, monitored for treatment with UFH during two time periods, were included (May to July 2014 and January to February 2015; n=254). OUTCOME MEASURES: Results of activated partial thromboplastin time (aPTT), thrombin time (TT), prothrombinase-induced clotting time (PiCT) and anti-Xa activity with respect to UFH concentration RESULTS: Spearman’s correlation coefficient (r(s)) with regard to anti-Xa activity was 0.68 (95% CI 0.60 to 0.75) for aPTT, 0.79 (0.69 to 0.86) for TT and 0.94 (0.93 to 0.95) for PiCT. The correlation (r(s)) between anti-Xa activity and heparin concentration as determined by spiking plasma samples was 1.0 (1.0 to 1.0). The coefficient of variation was at most 5% for PiCT and anti-Xa activity (within-run as well as day-to-day variability). The total costs per test in Swiss Francs (SFr) were SFr23.40 for aPTT, SFr33.30 for TT, SFr15.70 for PiCT and SFr24.15 for anti-Xa activity. The various tests were employed in Swiss institutions with the following frequencies: aPTT 53.2%, TT 21.6%, anti-Xa activity 7.2%, PiCT 1.4%; 16.6% of hospitals performed more than one test. CONCLUSIONS: The accuracy and reproducibility of PiCT and anti-Xa activity for monitoring of UFH was superior, and analytical costs were equivalent to or lower than aPTT and TT. BMJ Publishing Group 2018-06-09 /pmc/articles/PMC6009553/ /pubmed/29886450 http://dx.doi.org/10.1136/bmjopen-2018-022943 Text en © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted. This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
spellingShingle Cardiovascular Medicine
Bürki, Susanne
Brand, Béatrice
Escher, Robert
Wuillemin, Walter A
Nagler, Michael
Accuracy, reproducibility and costs of different laboratory assays for the monitoring of unfractionated heparin in clinical practice: a prospective evaluation study and survey among Swiss institutions
title Accuracy, reproducibility and costs of different laboratory assays for the monitoring of unfractionated heparin in clinical practice: a prospective evaluation study and survey among Swiss institutions
title_full Accuracy, reproducibility and costs of different laboratory assays for the monitoring of unfractionated heparin in clinical practice: a prospective evaluation study and survey among Swiss institutions
title_fullStr Accuracy, reproducibility and costs of different laboratory assays for the monitoring of unfractionated heparin in clinical practice: a prospective evaluation study and survey among Swiss institutions
title_full_unstemmed Accuracy, reproducibility and costs of different laboratory assays for the monitoring of unfractionated heparin in clinical practice: a prospective evaluation study and survey among Swiss institutions
title_short Accuracy, reproducibility and costs of different laboratory assays for the monitoring of unfractionated heparin in clinical practice: a prospective evaluation study and survey among Swiss institutions
title_sort accuracy, reproducibility and costs of different laboratory assays for the monitoring of unfractionated heparin in clinical practice: a prospective evaluation study and survey among swiss institutions
topic Cardiovascular Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6009553/
https://www.ncbi.nlm.nih.gov/pubmed/29886450
http://dx.doi.org/10.1136/bmjopen-2018-022943
work_keys_str_mv AT burkisusanne accuracyreproducibilityandcostsofdifferentlaboratoryassaysforthemonitoringofunfractionatedheparininclinicalpracticeaprospectiveevaluationstudyandsurveyamongswissinstitutions
AT brandbeatrice accuracyreproducibilityandcostsofdifferentlaboratoryassaysforthemonitoringofunfractionatedheparininclinicalpracticeaprospectiveevaluationstudyandsurveyamongswissinstitutions
AT escherrobert accuracyreproducibilityandcostsofdifferentlaboratoryassaysforthemonitoringofunfractionatedheparininclinicalpracticeaprospectiveevaluationstudyandsurveyamongswissinstitutions
AT wuilleminwaltera accuracyreproducibilityandcostsofdifferentlaboratoryassaysforthemonitoringofunfractionatedheparininclinicalpracticeaprospectiveevaluationstudyandsurveyamongswissinstitutions
AT naglermichael accuracyreproducibilityandcostsofdifferentlaboratoryassaysforthemonitoringofunfractionatedheparininclinicalpracticeaprospectiveevaluationstudyandsurveyamongswissinstitutions