Cargando…

Development and internal validation of a multivariable prediction model for tinnitus recovery following unilateral cochlear implantation: a cross-sectional retrospective study

OBJECTIVE: To develop and internally validate a prediction model for tinnitus recovery following unilateral cochlear implantation. DESIGN: A cross-sectional retrospective study. SETTING: A questionnaire concerning tinnitus was sent to patients with bilateral severe to profound hearing loss, who unde...

Descripción completa

Detalles Bibliográficos
Autores principales: Ramakers, Geerte G J, van Zanten, Gijsbert A, Thomeer, Hans G X M, Stokroos, Robert J, Heymans, Martijn W, Stegeman, Inge
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6009556/
https://www.ncbi.nlm.nih.gov/pubmed/29895652
http://dx.doi.org/10.1136/bmjopen-2017-021068
_version_ 1783333413323800576
author Ramakers, Geerte G J
van Zanten, Gijsbert A
Thomeer, Hans G X M
Stokroos, Robert J
Heymans, Martijn W
Stegeman, Inge
author_facet Ramakers, Geerte G J
van Zanten, Gijsbert A
Thomeer, Hans G X M
Stokroos, Robert J
Heymans, Martijn W
Stegeman, Inge
author_sort Ramakers, Geerte G J
collection PubMed
description OBJECTIVE: To develop and internally validate a prediction model for tinnitus recovery following unilateral cochlear implantation. DESIGN: A cross-sectional retrospective study. SETTING: A questionnaire concerning tinnitus was sent to patients with bilateral severe to profound hearing loss, who underwent unilateral cochlear implantation at the University Medical Center Utrecht, the Netherlands, between 1 January 2006 and 31 December 2015. PARTICIPANTS: Of 137 included patients, 87 patients experienced tinnitus preoperatively. Data of these 87 patients were used to develop the prediction model. PRIMARY AND SECONDARY OUTCOME MEASURES: The outcome of the prediction model was tinnitus recovery. Investigated predictors were: age, gender, duration of deafness, preoperative hearing performance, tinnitus duration, severity and localisation, follow-up duration, localisation of cochlear implant (CI) compared with tinnitus side, surgical approach, insertion depth of the electrode, CI brand and difference in hearing threshold following cochlear implantation. Multivariable backward logistic regression was performed. Missing data were handled using multiple imputation. The performance of the model was assessed by the calibrative and discriminative ability of the model. The prediction model was internally validated using bootstrapping techniques. RESULTS: The tinnitus recovery rate was 40%. A lower preoperative Consonant-Vowel-Consonant (CVC) score, unilateral localisation of tinnitus and larger deterioration of residual hearing at 250 Hz revealed to be relevant predictors for tinnitus recovery. The area under the receiver operating characteristics curve (AUC) of the initial model was 0.722 (IQR: 0.703–0.729). After internal validation of this prediction model, the AUC decreased to 0.696 (IQR: 0.667–0.700). CONCLUSION AND RELEVANCE: Lower preoperative CVC score, unilateral localisation of tinnitus and larger deterioration of residual hearing at 250 Hz were significant predictors for tinnitus recovery following unilateral cochlear implantation. The performance of the model developed in this retrospective study is promising. However, before clinical use of the model, the conduction of a larger prospective study is recommended.
format Online
Article
Text
id pubmed-6009556
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-60095562018-06-25 Development and internal validation of a multivariable prediction model for tinnitus recovery following unilateral cochlear implantation: a cross-sectional retrospective study Ramakers, Geerte G J van Zanten, Gijsbert A Thomeer, Hans G X M Stokroos, Robert J Heymans, Martijn W Stegeman, Inge BMJ Open Ear, Nose and Throat/Otolaryngology OBJECTIVE: To develop and internally validate a prediction model for tinnitus recovery following unilateral cochlear implantation. DESIGN: A cross-sectional retrospective study. SETTING: A questionnaire concerning tinnitus was sent to patients with bilateral severe to profound hearing loss, who underwent unilateral cochlear implantation at the University Medical Center Utrecht, the Netherlands, between 1 January 2006 and 31 December 2015. PARTICIPANTS: Of 137 included patients, 87 patients experienced tinnitus preoperatively. Data of these 87 patients were used to develop the prediction model. PRIMARY AND SECONDARY OUTCOME MEASURES: The outcome of the prediction model was tinnitus recovery. Investigated predictors were: age, gender, duration of deafness, preoperative hearing performance, tinnitus duration, severity and localisation, follow-up duration, localisation of cochlear implant (CI) compared with tinnitus side, surgical approach, insertion depth of the electrode, CI brand and difference in hearing threshold following cochlear implantation. Multivariable backward logistic regression was performed. Missing data were handled using multiple imputation. The performance of the model was assessed by the calibrative and discriminative ability of the model. The prediction model was internally validated using bootstrapping techniques. RESULTS: The tinnitus recovery rate was 40%. A lower preoperative Consonant-Vowel-Consonant (CVC) score, unilateral localisation of tinnitus and larger deterioration of residual hearing at 250 Hz revealed to be relevant predictors for tinnitus recovery. The area under the receiver operating characteristics curve (AUC) of the initial model was 0.722 (IQR: 0.703–0.729). After internal validation of this prediction model, the AUC decreased to 0.696 (IQR: 0.667–0.700). CONCLUSION AND RELEVANCE: Lower preoperative CVC score, unilateral localisation of tinnitus and larger deterioration of residual hearing at 250 Hz were significant predictors for tinnitus recovery following unilateral cochlear implantation. The performance of the model developed in this retrospective study is promising. However, before clinical use of the model, the conduction of a larger prospective study is recommended. BMJ Publishing Group 2018-06-11 /pmc/articles/PMC6009556/ /pubmed/29895652 http://dx.doi.org/10.1136/bmjopen-2017-021068 Text en © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted. This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
spellingShingle Ear, Nose and Throat/Otolaryngology
Ramakers, Geerte G J
van Zanten, Gijsbert A
Thomeer, Hans G X M
Stokroos, Robert J
Heymans, Martijn W
Stegeman, Inge
Development and internal validation of a multivariable prediction model for tinnitus recovery following unilateral cochlear implantation: a cross-sectional retrospective study
title Development and internal validation of a multivariable prediction model for tinnitus recovery following unilateral cochlear implantation: a cross-sectional retrospective study
title_full Development and internal validation of a multivariable prediction model for tinnitus recovery following unilateral cochlear implantation: a cross-sectional retrospective study
title_fullStr Development and internal validation of a multivariable prediction model for tinnitus recovery following unilateral cochlear implantation: a cross-sectional retrospective study
title_full_unstemmed Development and internal validation of a multivariable prediction model for tinnitus recovery following unilateral cochlear implantation: a cross-sectional retrospective study
title_short Development and internal validation of a multivariable prediction model for tinnitus recovery following unilateral cochlear implantation: a cross-sectional retrospective study
title_sort development and internal validation of a multivariable prediction model for tinnitus recovery following unilateral cochlear implantation: a cross-sectional retrospective study
topic Ear, Nose and Throat/Otolaryngology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6009556/
https://www.ncbi.nlm.nih.gov/pubmed/29895652
http://dx.doi.org/10.1136/bmjopen-2017-021068
work_keys_str_mv AT ramakersgeertegj developmentandinternalvalidationofamultivariablepredictionmodelfortinnitusrecoveryfollowingunilateralcochlearimplantationacrosssectionalretrospectivestudy
AT vanzantengijsberta developmentandinternalvalidationofamultivariablepredictionmodelfortinnitusrecoveryfollowingunilateralcochlearimplantationacrosssectionalretrospectivestudy
AT thomeerhansgxm developmentandinternalvalidationofamultivariablepredictionmodelfortinnitusrecoveryfollowingunilateralcochlearimplantationacrosssectionalretrospectivestudy
AT stokroosrobertj developmentandinternalvalidationofamultivariablepredictionmodelfortinnitusrecoveryfollowingunilateralcochlearimplantationacrosssectionalretrospectivestudy
AT heymansmartijnw developmentandinternalvalidationofamultivariablepredictionmodelfortinnitusrecoveryfollowingunilateralcochlearimplantationacrosssectionalretrospectivestudy
AT stegemaninge developmentandinternalvalidationofamultivariablepredictionmodelfortinnitusrecoveryfollowingunilateralcochlearimplantationacrosssectionalretrospectivestudy