Cargando…
Precise Detection of Wrist Pulse Using Digital Speckle Pattern Interferometry
Pulse diagnosis is one of the four diagnostic methods of traditional Chinese medicine. However it suffers from the lack of objective and efficient detection method. We propose a noncontact optical method to detect human wrist pulse, aiming at the precise determination of the temporal and spatial dis...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6011166/ https://www.ncbi.nlm.nih.gov/pubmed/29983719 http://dx.doi.org/10.1155/2018/4187349 |
_version_ | 1783333749322153984 |
---|---|
author | Zhang, Hengfei Wu, Sijin Li, Weixian Wang, Yonghong Dong, Mingli Yang, Lianxiang |
author_facet | Zhang, Hengfei Wu, Sijin Li, Weixian Wang, Yonghong Dong, Mingli Yang, Lianxiang |
author_sort | Zhang, Hengfei |
collection | PubMed |
description | Pulse diagnosis is one of the four diagnostic methods of traditional Chinese medicine. However it suffers from the lack of objective and efficient detection method. We propose a noncontact optical method to detect human wrist pulse, aiming at the precise determination of the temporal and spatial distributions of pulse. The method uses the spatial-carrier digital speckle pattern interferometry (DSPI) to measure the micro/nanoscale skin displacement dynamically. Significant improvements in DSPI measurement have been made to allow the DSPI to detect the comprehensive information of the arterial pulsation at locations of Cun, Guan, and Chi. The experimental results prove that the spatiotemporal distributions of pulse can be obtained by the proposed method. The obtained data can be further used to describe most of the pulse parameters such as rate, rhythm, depth, length, width, and contour. |
format | Online Article Text |
id | pubmed-6011166 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-60111662018-07-08 Precise Detection of Wrist Pulse Using Digital Speckle Pattern Interferometry Zhang, Hengfei Wu, Sijin Li, Weixian Wang, Yonghong Dong, Mingli Yang, Lianxiang Evid Based Complement Alternat Med Research Article Pulse diagnosis is one of the four diagnostic methods of traditional Chinese medicine. However it suffers from the lack of objective and efficient detection method. We propose a noncontact optical method to detect human wrist pulse, aiming at the precise determination of the temporal and spatial distributions of pulse. The method uses the spatial-carrier digital speckle pattern interferometry (DSPI) to measure the micro/nanoscale skin displacement dynamically. Significant improvements in DSPI measurement have been made to allow the DSPI to detect the comprehensive information of the arterial pulsation at locations of Cun, Guan, and Chi. The experimental results prove that the spatiotemporal distributions of pulse can be obtained by the proposed method. The obtained data can be further used to describe most of the pulse parameters such as rate, rhythm, depth, length, width, and contour. Hindawi 2018-06-07 /pmc/articles/PMC6011166/ /pubmed/29983719 http://dx.doi.org/10.1155/2018/4187349 Text en Copyright © 2018 Hengfei Zhang et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Zhang, Hengfei Wu, Sijin Li, Weixian Wang, Yonghong Dong, Mingli Yang, Lianxiang Precise Detection of Wrist Pulse Using Digital Speckle Pattern Interferometry |
title | Precise Detection of Wrist Pulse Using Digital Speckle Pattern Interferometry |
title_full | Precise Detection of Wrist Pulse Using Digital Speckle Pattern Interferometry |
title_fullStr | Precise Detection of Wrist Pulse Using Digital Speckle Pattern Interferometry |
title_full_unstemmed | Precise Detection of Wrist Pulse Using Digital Speckle Pattern Interferometry |
title_short | Precise Detection of Wrist Pulse Using Digital Speckle Pattern Interferometry |
title_sort | precise detection of wrist pulse using digital speckle pattern interferometry |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6011166/ https://www.ncbi.nlm.nih.gov/pubmed/29983719 http://dx.doi.org/10.1155/2018/4187349 |
work_keys_str_mv | AT zhanghengfei precisedetectionofwristpulseusingdigitalspecklepatterninterferometry AT wusijin precisedetectionofwristpulseusingdigitalspecklepatterninterferometry AT liweixian precisedetectionofwristpulseusingdigitalspecklepatterninterferometry AT wangyonghong precisedetectionofwristpulseusingdigitalspecklepatterninterferometry AT dongmingli precisedetectionofwristpulseusingdigitalspecklepatterninterferometry AT yanglianxiang precisedetectionofwristpulseusingdigitalspecklepatterninterferometry |