Cargando…

Clinical outcomes and structural integrity of C-shaped rotator cuff tears after arthroscopic repair: comparison with crescent-shaped tears

BACKGROUND: We aimed to describe a new C-shaped tear configuration, and to compare clinical outcomes and structural integrity between the C-shaped and the established crescent-shaped small to medium-sized rotator cuff tears after arthroscopic repair. METHODS: This retrospective study included 102 pa...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Wonyong, Kim, Sung-Jae, Choi, Chong-Hyuk, Choi, Yun-Rak, Chun, Yong-Min
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6011185/
https://www.ncbi.nlm.nih.gov/pubmed/29921299
http://dx.doi.org/10.1186/s13018-018-0863-5
_version_ 1783333753597198336
author Lee, Wonyong
Kim, Sung-Jae
Choi, Chong-Hyuk
Choi, Yun-Rak
Chun, Yong-Min
author_facet Lee, Wonyong
Kim, Sung-Jae
Choi, Chong-Hyuk
Choi, Yun-Rak
Chun, Yong-Min
author_sort Lee, Wonyong
collection PubMed
description BACKGROUND: We aimed to describe a new C-shaped tear configuration, and to compare clinical outcomes and structural integrity between the C-shaped and the established crescent-shaped small to medium-sized rotator cuff tears after arthroscopic repair. METHODS: This retrospective study included 102 patients who underwent arthroscopic repair in a single-row fashion for small- to medium-sized rotator cuff tears of either C or crescent shape from March 2009 to June 2014. Visual analogue scale (VAS) pain score, subjective shoulder value (SSV), American Shoulder and Elbow Surgeon (ASES) score, and active range of motion (ROM) were evaluated for functional outcomes. Postoperative magnetic resonance arthrography (MRA) or computed tomographic arthrography (CTA) was performed 6 months postoperatively to assess structural integrity. RESULTS: After 2 years of follow-up, both groups showed no significant difference in VAS pain score, functional scores, or ROM, although the C-shaped tear group exhibited significantly inferior outcomes 3 months after surgery. There was no significant difference in the re-tear rate on follow-up MRA and CTA between groups A and B (24.4 vs. 19.7%, respectively; p = 0.570). The postoperative stiffness rate was significantly higher in the C-shaped tear group than that in crescent-shaped tear group only at 3-month follow-up point after surgery (26.8 vs. 9.8%, respectively; p = 0.024). CONCLUSIONS: Contrary to our hypothesis, there were no significant differences in functional outcomes and structural integrity between C-shaped and crescent-shaped small- to medium-sized tears 2 years after arthroscopic repair. However, C-shaped tears exhibited significantly worse clinical outcomes, including a higher postoperative stiffness rate than crescent-shaped tears in the early postoperative period at the 3-month follow-up point.
format Online
Article
Text
id pubmed-6011185
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-60111852018-06-27 Clinical outcomes and structural integrity of C-shaped rotator cuff tears after arthroscopic repair: comparison with crescent-shaped tears Lee, Wonyong Kim, Sung-Jae Choi, Chong-Hyuk Choi, Yun-Rak Chun, Yong-Min J Orthop Surg Res Research Article BACKGROUND: We aimed to describe a new C-shaped tear configuration, and to compare clinical outcomes and structural integrity between the C-shaped and the established crescent-shaped small to medium-sized rotator cuff tears after arthroscopic repair. METHODS: This retrospective study included 102 patients who underwent arthroscopic repair in a single-row fashion for small- to medium-sized rotator cuff tears of either C or crescent shape from March 2009 to June 2014. Visual analogue scale (VAS) pain score, subjective shoulder value (SSV), American Shoulder and Elbow Surgeon (ASES) score, and active range of motion (ROM) were evaluated for functional outcomes. Postoperative magnetic resonance arthrography (MRA) or computed tomographic arthrography (CTA) was performed 6 months postoperatively to assess structural integrity. RESULTS: After 2 years of follow-up, both groups showed no significant difference in VAS pain score, functional scores, or ROM, although the C-shaped tear group exhibited significantly inferior outcomes 3 months after surgery. There was no significant difference in the re-tear rate on follow-up MRA and CTA between groups A and B (24.4 vs. 19.7%, respectively; p = 0.570). The postoperative stiffness rate was significantly higher in the C-shaped tear group than that in crescent-shaped tear group only at 3-month follow-up point after surgery (26.8 vs. 9.8%, respectively; p = 0.024). CONCLUSIONS: Contrary to our hypothesis, there were no significant differences in functional outcomes and structural integrity between C-shaped and crescent-shaped small- to medium-sized tears 2 years after arthroscopic repair. However, C-shaped tears exhibited significantly worse clinical outcomes, including a higher postoperative stiffness rate than crescent-shaped tears in the early postoperative period at the 3-month follow-up point. BioMed Central 2018-06-19 /pmc/articles/PMC6011185/ /pubmed/29921299 http://dx.doi.org/10.1186/s13018-018-0863-5 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Lee, Wonyong
Kim, Sung-Jae
Choi, Chong-Hyuk
Choi, Yun-Rak
Chun, Yong-Min
Clinical outcomes and structural integrity of C-shaped rotator cuff tears after arthroscopic repair: comparison with crescent-shaped tears
title Clinical outcomes and structural integrity of C-shaped rotator cuff tears after arthroscopic repair: comparison with crescent-shaped tears
title_full Clinical outcomes and structural integrity of C-shaped rotator cuff tears after arthroscopic repair: comparison with crescent-shaped tears
title_fullStr Clinical outcomes and structural integrity of C-shaped rotator cuff tears after arthroscopic repair: comparison with crescent-shaped tears
title_full_unstemmed Clinical outcomes and structural integrity of C-shaped rotator cuff tears after arthroscopic repair: comparison with crescent-shaped tears
title_short Clinical outcomes and structural integrity of C-shaped rotator cuff tears after arthroscopic repair: comparison with crescent-shaped tears
title_sort clinical outcomes and structural integrity of c-shaped rotator cuff tears after arthroscopic repair: comparison with crescent-shaped tears
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6011185/
https://www.ncbi.nlm.nih.gov/pubmed/29921299
http://dx.doi.org/10.1186/s13018-018-0863-5
work_keys_str_mv AT leewonyong clinicaloutcomesandstructuralintegrityofcshapedrotatorcufftearsafterarthroscopicrepaircomparisonwithcrescentshapedtears
AT kimsungjae clinicaloutcomesandstructuralintegrityofcshapedrotatorcufftearsafterarthroscopicrepaircomparisonwithcrescentshapedtears
AT choichonghyuk clinicaloutcomesandstructuralintegrityofcshapedrotatorcufftearsafterarthroscopicrepaircomparisonwithcrescentshapedtears
AT choiyunrak clinicaloutcomesandstructuralintegrityofcshapedrotatorcufftearsafterarthroscopicrepaircomparisonwithcrescentshapedtears
AT chunyongmin clinicaloutcomesandstructuralintegrityofcshapedrotatorcufftearsafterarthroscopicrepaircomparisonwithcrescentshapedtears