Cargando…
Perfluorocarbon liquid-assisted intraocular foreign body removal
We describe the benefits of perfluoro-N-octane (PFO), a perfluorocarbon liquid, in the removal of nonmagnetic intraocular foreign bodies (IOFBs) from the macula and posterior segment. Two consecutive cases of posterior segment IOFB were reviewed. An 18-year-old male presented to the emergency room a...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6012550/ https://www.ncbi.nlm.nih.gov/pubmed/29950804 http://dx.doi.org/10.2147/OPTH.S159509 |
_version_ | 1783333935967633408 |
---|---|
author | Ung, Cindy Laíns, Inês Papakostas, Thanos D Rahmani, Safa Miller, John B |
author_facet | Ung, Cindy Laíns, Inês Papakostas, Thanos D Rahmani, Safa Miller, John B |
author_sort | Ung, Cindy |
collection | PubMed |
description | We describe the benefits of perfluoro-N-octane (PFO), a perfluorocarbon liquid, in the removal of nonmagnetic intraocular foreign bodies (IOFBs) from the macula and posterior segment. Two consecutive cases of posterior segment IOFB were reviewed. An 18-year-old male presented to the emergency room after a motor vehicle accident with a zone 1 open globe injury and large glass IOFB in the left eye. A 53-year-old male presented to the emergency room with a history of a 3-week delayed presentation of a zone 1 open globe injury from a nail to the right eye. He was found to have a metallic IOFB. In both cases, PFO was used to slide the nonmagnetic IOFBs outside of the macula for safer retrieval. PFO was also able to protect the posterior pole from IOFB drops during early attempts at removal. PFO can be a useful surgical adjunct to pars plana vitrectomy in the removal of certain nonmagnetic IOFBs. |
format | Online Article Text |
id | pubmed-6012550 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-60125502018-06-27 Perfluorocarbon liquid-assisted intraocular foreign body removal Ung, Cindy Laíns, Inês Papakostas, Thanos D Rahmani, Safa Miller, John B Clin Ophthalmol Methodology We describe the benefits of perfluoro-N-octane (PFO), a perfluorocarbon liquid, in the removal of nonmagnetic intraocular foreign bodies (IOFBs) from the macula and posterior segment. Two consecutive cases of posterior segment IOFB were reviewed. An 18-year-old male presented to the emergency room after a motor vehicle accident with a zone 1 open globe injury and large glass IOFB in the left eye. A 53-year-old male presented to the emergency room with a history of a 3-week delayed presentation of a zone 1 open globe injury from a nail to the right eye. He was found to have a metallic IOFB. In both cases, PFO was used to slide the nonmagnetic IOFBs outside of the macula for safer retrieval. PFO was also able to protect the posterior pole from IOFB drops during early attempts at removal. PFO can be a useful surgical adjunct to pars plana vitrectomy in the removal of certain nonmagnetic IOFBs. Dove Medical Press 2018-06-18 /pmc/articles/PMC6012550/ /pubmed/29950804 http://dx.doi.org/10.2147/OPTH.S159509 Text en © 2018 Ung et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Methodology Ung, Cindy Laíns, Inês Papakostas, Thanos D Rahmani, Safa Miller, John B Perfluorocarbon liquid-assisted intraocular foreign body removal |
title | Perfluorocarbon liquid-assisted intraocular foreign body removal |
title_full | Perfluorocarbon liquid-assisted intraocular foreign body removal |
title_fullStr | Perfluorocarbon liquid-assisted intraocular foreign body removal |
title_full_unstemmed | Perfluorocarbon liquid-assisted intraocular foreign body removal |
title_short | Perfluorocarbon liquid-assisted intraocular foreign body removal |
title_sort | perfluorocarbon liquid-assisted intraocular foreign body removal |
topic | Methodology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6012550/ https://www.ncbi.nlm.nih.gov/pubmed/29950804 http://dx.doi.org/10.2147/OPTH.S159509 |
work_keys_str_mv | AT ungcindy perfluorocarbonliquidassistedintraocularforeignbodyremoval AT lainsines perfluorocarbonliquidassistedintraocularforeignbodyremoval AT papakostasthanosd perfluorocarbonliquidassistedintraocularforeignbodyremoval AT rahmanisafa perfluorocarbonliquidassistedintraocularforeignbodyremoval AT millerjohnb perfluorocarbonliquidassistedintraocularforeignbodyremoval |