Cargando…

Methodology for Y Chromosome Capture: A complete genome sequence of  Y chromosome using flow cytometry, laser microdissection and magnetic streptavidin-beads

This study is a comparison of the efficiency of three technologies used for Y chromosome capture and the next-generation sequencing (NGS) technologies applied for determining its whole sequence. Our main findings disclose that streptavidin–biotin magnetic particle-based capture methodology offers be...

Descripción completa

Detalles Bibliográficos
Autores principales: Alvarez-Cubero, M. J., Santiago, O., Martínez-Labarga, C., Martínez-García, B., Marrero- Díaz, R., Rubio-Roldan, A., Pérez-Gutiérrez, A. M., Carmona-Saez, P., Lorente, J. A., Martinez-Gonzalez, L. J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6013464/
https://www.ncbi.nlm.nih.gov/pubmed/29930304
http://dx.doi.org/10.1038/s41598-018-27819-x
_version_ 1783334016900923392
author Alvarez-Cubero, M. J.
Santiago, O.
Martínez-Labarga, C.
Martínez-García, B.
Marrero- Díaz, R.
Rubio-Roldan, A.
Pérez-Gutiérrez, A. M.
Carmona-Saez, P.
Lorente, J. A.
Martinez-Gonzalez, L. J.
author_facet Alvarez-Cubero, M. J.
Santiago, O.
Martínez-Labarga, C.
Martínez-García, B.
Marrero- Díaz, R.
Rubio-Roldan, A.
Pérez-Gutiérrez, A. M.
Carmona-Saez, P.
Lorente, J. A.
Martinez-Gonzalez, L. J.
author_sort Alvarez-Cubero, M. J.
collection PubMed
description This study is a comparison of the efficiency of three technologies used for Y chromosome capture and the next-generation sequencing (NGS) technologies applied for determining its whole sequence. Our main findings disclose that streptavidin–biotin magnetic particle-based capture methodology offers better and a deeper sequence coverage for Y chromosome capture, compared to chromosome sorting and microdissection procedures. Moreover, this methodology is less time consuming and the most selective for capturing only Y chromosomal material, in contrast with other methodologies that result in considerable background material from other, non-targeted chromosomes. NGS results compared between two platforms, NextSeq 500 and SOLID 5500xl, produce the same coverage results. This is the first study to explore a methodological comparison of Y chromosome capture and genetic analysis. Our results indicate an improved strategy for Y chromosome research with applications in several scientific fields where this chromosome plays an important role, such as forensics, medical sciences, molecular anthropology and cancer sciences.
format Online
Article
Text
id pubmed-6013464
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-60134642018-06-27 Methodology for Y Chromosome Capture: A complete genome sequence of  Y chromosome using flow cytometry, laser microdissection and magnetic streptavidin-beads Alvarez-Cubero, M. J. Santiago, O. Martínez-Labarga, C. Martínez-García, B. Marrero- Díaz, R. Rubio-Roldan, A. Pérez-Gutiérrez, A. M. Carmona-Saez, P. Lorente, J. A. Martinez-Gonzalez, L. J. Sci Rep Article This study is a comparison of the efficiency of three technologies used for Y chromosome capture and the next-generation sequencing (NGS) technologies applied for determining its whole sequence. Our main findings disclose that streptavidin–biotin magnetic particle-based capture methodology offers better and a deeper sequence coverage for Y chromosome capture, compared to chromosome sorting and microdissection procedures. Moreover, this methodology is less time consuming and the most selective for capturing only Y chromosomal material, in contrast with other methodologies that result in considerable background material from other, non-targeted chromosomes. NGS results compared between two platforms, NextSeq 500 and SOLID 5500xl, produce the same coverage results. This is the first study to explore a methodological comparison of Y chromosome capture and genetic analysis. Our results indicate an improved strategy for Y chromosome research with applications in several scientific fields where this chromosome plays an important role, such as forensics, medical sciences, molecular anthropology and cancer sciences. Nature Publishing Group UK 2018-06-21 /pmc/articles/PMC6013464/ /pubmed/29930304 http://dx.doi.org/10.1038/s41598-018-27819-x Text en © The Author(s) 2018 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Alvarez-Cubero, M. J.
Santiago, O.
Martínez-Labarga, C.
Martínez-García, B.
Marrero- Díaz, R.
Rubio-Roldan, A.
Pérez-Gutiérrez, A. M.
Carmona-Saez, P.
Lorente, J. A.
Martinez-Gonzalez, L. J.
Methodology for Y Chromosome Capture: A complete genome sequence of  Y chromosome using flow cytometry, laser microdissection and magnetic streptavidin-beads
title Methodology for Y Chromosome Capture: A complete genome sequence of  Y chromosome using flow cytometry, laser microdissection and magnetic streptavidin-beads
title_full Methodology for Y Chromosome Capture: A complete genome sequence of  Y chromosome using flow cytometry, laser microdissection and magnetic streptavidin-beads
title_fullStr Methodology for Y Chromosome Capture: A complete genome sequence of  Y chromosome using flow cytometry, laser microdissection and magnetic streptavidin-beads
title_full_unstemmed Methodology for Y Chromosome Capture: A complete genome sequence of  Y chromosome using flow cytometry, laser microdissection and magnetic streptavidin-beads
title_short Methodology for Y Chromosome Capture: A complete genome sequence of  Y chromosome using flow cytometry, laser microdissection and magnetic streptavidin-beads
title_sort methodology for y chromosome capture: a complete genome sequence of  y chromosome using flow cytometry, laser microdissection and magnetic streptavidin-beads
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6013464/
https://www.ncbi.nlm.nih.gov/pubmed/29930304
http://dx.doi.org/10.1038/s41598-018-27819-x
work_keys_str_mv AT alvarezcuberomj methodologyforychromosomecaptureacompletegenomesequenceofychromosomeusingflowcytometrylasermicrodissectionandmagneticstreptavidinbeads
AT santiagoo methodologyforychromosomecaptureacompletegenomesequenceofychromosomeusingflowcytometrylasermicrodissectionandmagneticstreptavidinbeads
AT martinezlabargac methodologyforychromosomecaptureacompletegenomesequenceofychromosomeusingflowcytometrylasermicrodissectionandmagneticstreptavidinbeads
AT martinezgarciab methodologyforychromosomecaptureacompletegenomesequenceofychromosomeusingflowcytometrylasermicrodissectionandmagneticstreptavidinbeads
AT marrerodiazr methodologyforychromosomecaptureacompletegenomesequenceofychromosomeusingflowcytometrylasermicrodissectionandmagneticstreptavidinbeads
AT rubioroldana methodologyforychromosomecaptureacompletegenomesequenceofychromosomeusingflowcytometrylasermicrodissectionandmagneticstreptavidinbeads
AT perezgutierrezam methodologyforychromosomecaptureacompletegenomesequenceofychromosomeusingflowcytometrylasermicrodissectionandmagneticstreptavidinbeads
AT carmonasaezp methodologyforychromosomecaptureacompletegenomesequenceofychromosomeusingflowcytometrylasermicrodissectionandmagneticstreptavidinbeads
AT lorenteja methodologyforychromosomecaptureacompletegenomesequenceofychromosomeusingflowcytometrylasermicrodissectionandmagneticstreptavidinbeads
AT martinezgonzalezlj methodologyforychromosomecaptureacompletegenomesequenceofychromosomeusingflowcytometrylasermicrodissectionandmagneticstreptavidinbeads