Cargando…

UPLC-QTOF/MS(E) and Bioassay Are Available Approaches for Identifying Quality Fluctuation of Xueshuantong Lyophilized Powder in Clinic

Xueshuantong Lyophilized Powder (XST), consisting of a series of saponins extracted from Panax notoginseng, is widely applied to treat acute cerebral infarction, stroke, and coronary heart disease in China. However, most adverse drug reactions (ADR) in clinic are caused by quality problems of XST. I...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Zhi-Rui, Wang, Zi-Hao, Tang, Jin-Fa, Yan, Yan, Yue, Shi-Jun, Feng, Wu-Wen, Shi, Zheng-Yuan, Meng, Xin-Tong, Peng, Cheng, Wang, Chang-Yun, Meng, Da-Li, Yan, Dan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6013573/
https://www.ncbi.nlm.nih.gov/pubmed/29962950
http://dx.doi.org/10.3389/fphar.2018.00633
_version_ 1783334042399145984
author Yang, Zhi-Rui
Wang, Zi-Hao
Tang, Jin-Fa
Yan, Yan
Yue, Shi-Jun
Feng, Wu-Wen
Shi, Zheng-Yuan
Meng, Xin-Tong
Peng, Cheng
Wang, Chang-Yun
Meng, Da-Li
Yan, Dan
author_facet Yang, Zhi-Rui
Wang, Zi-Hao
Tang, Jin-Fa
Yan, Yan
Yue, Shi-Jun
Feng, Wu-Wen
Shi, Zheng-Yuan
Meng, Xin-Tong
Peng, Cheng
Wang, Chang-Yun
Meng, Da-Li
Yan, Dan
author_sort Yang, Zhi-Rui
collection PubMed
description Xueshuantong Lyophilized Powder (XST), consisting of a series of saponins extracted from Panax notoginseng, is widely applied to treat acute cerebral infarction, stroke, and coronary heart disease in China. However, most adverse drug reactions (ADR) in clinic are caused by quality problems of XST. In this study, six batches of certainly abnormal, four batches of possibly abnormal XST, and eight batches of normal XST were obtained from the clinical practice. Their quality fluctuations were identified by ultra-performance liquid chromatography coupled with an electrospray ionization quadrupole time-of-flight mass spectrometry operating in MS(E) mode (UPLC-QTOF/MS(E)) and bioassays including antithrombin and proplasmin assay. Fourteen potential components responsible for clinical ADR were identified by UPLC-QTOF/MS(E), especially ginsenoside Rg1, Rg3, Rb1 and notoginsenoside R1. In addition, 83.3% (5/6) and 50.0% (3/6) certainly abnormal samples could be identified by UPLC-QTOF/MS(E) and bioassay, respectively. Interestingly, further integration of the two methods could entirely identify all the certainly abnormal samples and inferred that all the possibly abnormal samples were closely related to their quality fluctuation. It indicates that it is advisable to combine UPLC-QTOF/MS(E) and bioassay for identifying quality fluctuation of XST, and thus reduce its ADR in clinic.
format Online
Article
Text
id pubmed-6013573
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-60135732018-06-29 UPLC-QTOF/MS(E) and Bioassay Are Available Approaches for Identifying Quality Fluctuation of Xueshuantong Lyophilized Powder in Clinic Yang, Zhi-Rui Wang, Zi-Hao Tang, Jin-Fa Yan, Yan Yue, Shi-Jun Feng, Wu-Wen Shi, Zheng-Yuan Meng, Xin-Tong Peng, Cheng Wang, Chang-Yun Meng, Da-Li Yan, Dan Front Pharmacol Pharmacology Xueshuantong Lyophilized Powder (XST), consisting of a series of saponins extracted from Panax notoginseng, is widely applied to treat acute cerebral infarction, stroke, and coronary heart disease in China. However, most adverse drug reactions (ADR) in clinic are caused by quality problems of XST. In this study, six batches of certainly abnormal, four batches of possibly abnormal XST, and eight batches of normal XST were obtained from the clinical practice. Their quality fluctuations were identified by ultra-performance liquid chromatography coupled with an electrospray ionization quadrupole time-of-flight mass spectrometry operating in MS(E) mode (UPLC-QTOF/MS(E)) and bioassays including antithrombin and proplasmin assay. Fourteen potential components responsible for clinical ADR were identified by UPLC-QTOF/MS(E), especially ginsenoside Rg1, Rg3, Rb1 and notoginsenoside R1. In addition, 83.3% (5/6) and 50.0% (3/6) certainly abnormal samples could be identified by UPLC-QTOF/MS(E) and bioassay, respectively. Interestingly, further integration of the two methods could entirely identify all the certainly abnormal samples and inferred that all the possibly abnormal samples were closely related to their quality fluctuation. It indicates that it is advisable to combine UPLC-QTOF/MS(E) and bioassay for identifying quality fluctuation of XST, and thus reduce its ADR in clinic. Frontiers Media S.A. 2018-06-15 /pmc/articles/PMC6013573/ /pubmed/29962950 http://dx.doi.org/10.3389/fphar.2018.00633 Text en Copyright © 2018 Yang, Wang, Tang, Yan, Yue, Feng, Shi, Meng, Peng, Wang, Meng and Yan. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Pharmacology
Yang, Zhi-Rui
Wang, Zi-Hao
Tang, Jin-Fa
Yan, Yan
Yue, Shi-Jun
Feng, Wu-Wen
Shi, Zheng-Yuan
Meng, Xin-Tong
Peng, Cheng
Wang, Chang-Yun
Meng, Da-Li
Yan, Dan
UPLC-QTOF/MS(E) and Bioassay Are Available Approaches for Identifying Quality Fluctuation of Xueshuantong Lyophilized Powder in Clinic
title UPLC-QTOF/MS(E) and Bioassay Are Available Approaches for Identifying Quality Fluctuation of Xueshuantong Lyophilized Powder in Clinic
title_full UPLC-QTOF/MS(E) and Bioassay Are Available Approaches for Identifying Quality Fluctuation of Xueshuantong Lyophilized Powder in Clinic
title_fullStr UPLC-QTOF/MS(E) and Bioassay Are Available Approaches for Identifying Quality Fluctuation of Xueshuantong Lyophilized Powder in Clinic
title_full_unstemmed UPLC-QTOF/MS(E) and Bioassay Are Available Approaches for Identifying Quality Fluctuation of Xueshuantong Lyophilized Powder in Clinic
title_short UPLC-QTOF/MS(E) and Bioassay Are Available Approaches for Identifying Quality Fluctuation of Xueshuantong Lyophilized Powder in Clinic
title_sort uplc-qtof/ms(e) and bioassay are available approaches for identifying quality fluctuation of xueshuantong lyophilized powder in clinic
topic Pharmacology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6013573/
https://www.ncbi.nlm.nih.gov/pubmed/29962950
http://dx.doi.org/10.3389/fphar.2018.00633
work_keys_str_mv AT yangzhirui uplcqtofmseandbioassayareavailableapproachesforidentifyingqualityfluctuationofxueshuantonglyophilizedpowderinclinic
AT wangzihao uplcqtofmseandbioassayareavailableapproachesforidentifyingqualityfluctuationofxueshuantonglyophilizedpowderinclinic
AT tangjinfa uplcqtofmseandbioassayareavailableapproachesforidentifyingqualityfluctuationofxueshuantonglyophilizedpowderinclinic
AT yanyan uplcqtofmseandbioassayareavailableapproachesforidentifyingqualityfluctuationofxueshuantonglyophilizedpowderinclinic
AT yueshijun uplcqtofmseandbioassayareavailableapproachesforidentifyingqualityfluctuationofxueshuantonglyophilizedpowderinclinic
AT fengwuwen uplcqtofmseandbioassayareavailableapproachesforidentifyingqualityfluctuationofxueshuantonglyophilizedpowderinclinic
AT shizhengyuan uplcqtofmseandbioassayareavailableapproachesforidentifyingqualityfluctuationofxueshuantonglyophilizedpowderinclinic
AT mengxintong uplcqtofmseandbioassayareavailableapproachesforidentifyingqualityfluctuationofxueshuantonglyophilizedpowderinclinic
AT pengcheng uplcqtofmseandbioassayareavailableapproachesforidentifyingqualityfluctuationofxueshuantonglyophilizedpowderinclinic
AT wangchangyun uplcqtofmseandbioassayareavailableapproachesforidentifyingqualityfluctuationofxueshuantonglyophilizedpowderinclinic
AT mengdali uplcqtofmseandbioassayareavailableapproachesforidentifyingqualityfluctuationofxueshuantonglyophilizedpowderinclinic
AT yandan uplcqtofmseandbioassayareavailableapproachesforidentifyingqualityfluctuationofxueshuantonglyophilizedpowderinclinic