Cargando…
UPLC-QTOF/MS(E) and Bioassay Are Available Approaches for Identifying Quality Fluctuation of Xueshuantong Lyophilized Powder in Clinic
Xueshuantong Lyophilized Powder (XST), consisting of a series of saponins extracted from Panax notoginseng, is widely applied to treat acute cerebral infarction, stroke, and coronary heart disease in China. However, most adverse drug reactions (ADR) in clinic are caused by quality problems of XST. I...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6013573/ https://www.ncbi.nlm.nih.gov/pubmed/29962950 http://dx.doi.org/10.3389/fphar.2018.00633 |
_version_ | 1783334042399145984 |
---|---|
author | Yang, Zhi-Rui Wang, Zi-Hao Tang, Jin-Fa Yan, Yan Yue, Shi-Jun Feng, Wu-Wen Shi, Zheng-Yuan Meng, Xin-Tong Peng, Cheng Wang, Chang-Yun Meng, Da-Li Yan, Dan |
author_facet | Yang, Zhi-Rui Wang, Zi-Hao Tang, Jin-Fa Yan, Yan Yue, Shi-Jun Feng, Wu-Wen Shi, Zheng-Yuan Meng, Xin-Tong Peng, Cheng Wang, Chang-Yun Meng, Da-Li Yan, Dan |
author_sort | Yang, Zhi-Rui |
collection | PubMed |
description | Xueshuantong Lyophilized Powder (XST), consisting of a series of saponins extracted from Panax notoginseng, is widely applied to treat acute cerebral infarction, stroke, and coronary heart disease in China. However, most adverse drug reactions (ADR) in clinic are caused by quality problems of XST. In this study, six batches of certainly abnormal, four batches of possibly abnormal XST, and eight batches of normal XST were obtained from the clinical practice. Their quality fluctuations were identified by ultra-performance liquid chromatography coupled with an electrospray ionization quadrupole time-of-flight mass spectrometry operating in MS(E) mode (UPLC-QTOF/MS(E)) and bioassays including antithrombin and proplasmin assay. Fourteen potential components responsible for clinical ADR were identified by UPLC-QTOF/MS(E), especially ginsenoside Rg1, Rg3, Rb1 and notoginsenoside R1. In addition, 83.3% (5/6) and 50.0% (3/6) certainly abnormal samples could be identified by UPLC-QTOF/MS(E) and bioassay, respectively. Interestingly, further integration of the two methods could entirely identify all the certainly abnormal samples and inferred that all the possibly abnormal samples were closely related to their quality fluctuation. It indicates that it is advisable to combine UPLC-QTOF/MS(E) and bioassay for identifying quality fluctuation of XST, and thus reduce its ADR in clinic. |
format | Online Article Text |
id | pubmed-6013573 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-60135732018-06-29 UPLC-QTOF/MS(E) and Bioassay Are Available Approaches for Identifying Quality Fluctuation of Xueshuantong Lyophilized Powder in Clinic Yang, Zhi-Rui Wang, Zi-Hao Tang, Jin-Fa Yan, Yan Yue, Shi-Jun Feng, Wu-Wen Shi, Zheng-Yuan Meng, Xin-Tong Peng, Cheng Wang, Chang-Yun Meng, Da-Li Yan, Dan Front Pharmacol Pharmacology Xueshuantong Lyophilized Powder (XST), consisting of a series of saponins extracted from Panax notoginseng, is widely applied to treat acute cerebral infarction, stroke, and coronary heart disease in China. However, most adverse drug reactions (ADR) in clinic are caused by quality problems of XST. In this study, six batches of certainly abnormal, four batches of possibly abnormal XST, and eight batches of normal XST were obtained from the clinical practice. Their quality fluctuations were identified by ultra-performance liquid chromatography coupled with an electrospray ionization quadrupole time-of-flight mass spectrometry operating in MS(E) mode (UPLC-QTOF/MS(E)) and bioassays including antithrombin and proplasmin assay. Fourteen potential components responsible for clinical ADR were identified by UPLC-QTOF/MS(E), especially ginsenoside Rg1, Rg3, Rb1 and notoginsenoside R1. In addition, 83.3% (5/6) and 50.0% (3/6) certainly abnormal samples could be identified by UPLC-QTOF/MS(E) and bioassay, respectively. Interestingly, further integration of the two methods could entirely identify all the certainly abnormal samples and inferred that all the possibly abnormal samples were closely related to their quality fluctuation. It indicates that it is advisable to combine UPLC-QTOF/MS(E) and bioassay for identifying quality fluctuation of XST, and thus reduce its ADR in clinic. Frontiers Media S.A. 2018-06-15 /pmc/articles/PMC6013573/ /pubmed/29962950 http://dx.doi.org/10.3389/fphar.2018.00633 Text en Copyright © 2018 Yang, Wang, Tang, Yan, Yue, Feng, Shi, Meng, Peng, Wang, Meng and Yan. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Pharmacology Yang, Zhi-Rui Wang, Zi-Hao Tang, Jin-Fa Yan, Yan Yue, Shi-Jun Feng, Wu-Wen Shi, Zheng-Yuan Meng, Xin-Tong Peng, Cheng Wang, Chang-Yun Meng, Da-Li Yan, Dan UPLC-QTOF/MS(E) and Bioassay Are Available Approaches for Identifying Quality Fluctuation of Xueshuantong Lyophilized Powder in Clinic |
title | UPLC-QTOF/MS(E) and Bioassay Are Available Approaches for Identifying Quality Fluctuation of Xueshuantong Lyophilized Powder in Clinic |
title_full | UPLC-QTOF/MS(E) and Bioassay Are Available Approaches for Identifying Quality Fluctuation of Xueshuantong Lyophilized Powder in Clinic |
title_fullStr | UPLC-QTOF/MS(E) and Bioassay Are Available Approaches for Identifying Quality Fluctuation of Xueshuantong Lyophilized Powder in Clinic |
title_full_unstemmed | UPLC-QTOF/MS(E) and Bioassay Are Available Approaches for Identifying Quality Fluctuation of Xueshuantong Lyophilized Powder in Clinic |
title_short | UPLC-QTOF/MS(E) and Bioassay Are Available Approaches for Identifying Quality Fluctuation of Xueshuantong Lyophilized Powder in Clinic |
title_sort | uplc-qtof/ms(e) and bioassay are available approaches for identifying quality fluctuation of xueshuantong lyophilized powder in clinic |
topic | Pharmacology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6013573/ https://www.ncbi.nlm.nih.gov/pubmed/29962950 http://dx.doi.org/10.3389/fphar.2018.00633 |
work_keys_str_mv | AT yangzhirui uplcqtofmseandbioassayareavailableapproachesforidentifyingqualityfluctuationofxueshuantonglyophilizedpowderinclinic AT wangzihao uplcqtofmseandbioassayareavailableapproachesforidentifyingqualityfluctuationofxueshuantonglyophilizedpowderinclinic AT tangjinfa uplcqtofmseandbioassayareavailableapproachesforidentifyingqualityfluctuationofxueshuantonglyophilizedpowderinclinic AT yanyan uplcqtofmseandbioassayareavailableapproachesforidentifyingqualityfluctuationofxueshuantonglyophilizedpowderinclinic AT yueshijun uplcqtofmseandbioassayareavailableapproachesforidentifyingqualityfluctuationofxueshuantonglyophilizedpowderinclinic AT fengwuwen uplcqtofmseandbioassayareavailableapproachesforidentifyingqualityfluctuationofxueshuantonglyophilizedpowderinclinic AT shizhengyuan uplcqtofmseandbioassayareavailableapproachesforidentifyingqualityfluctuationofxueshuantonglyophilizedpowderinclinic AT mengxintong uplcqtofmseandbioassayareavailableapproachesforidentifyingqualityfluctuationofxueshuantonglyophilizedpowderinclinic AT pengcheng uplcqtofmseandbioassayareavailableapproachesforidentifyingqualityfluctuationofxueshuantonglyophilizedpowderinclinic AT wangchangyun uplcqtofmseandbioassayareavailableapproachesforidentifyingqualityfluctuationofxueshuantonglyophilizedpowderinclinic AT mengdali uplcqtofmseandbioassayareavailableapproachesforidentifyingqualityfluctuationofxueshuantonglyophilizedpowderinclinic AT yandan uplcqtofmseandbioassayareavailableapproachesforidentifyingqualityfluctuationofxueshuantonglyophilizedpowderinclinic |