Cargando…
Cerebral Protection During Transcatheter Aortic Valve Implantation: An Updated Systematic Review and Meta‐Analysis
BACKGROUND: The use of embolic protection devices (EPD) may theoretically reduce the occurrence of cerebral embolic lesions during transcatheter aortic valve implantation. Available evidence from single studies is inconclusive. The aim of the present meta‐analysis was to assess the safety and effica...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6015324/ https://www.ncbi.nlm.nih.gov/pubmed/29728369 http://dx.doi.org/10.1161/JAHA.117.008463 |
_version_ | 1783334386249236480 |
---|---|
author | Testa, Luca Latib, Azeem Casenghi, Matteo Gorla, Riccardo Colombo, Antonio Bedogni, Francesco |
author_facet | Testa, Luca Latib, Azeem Casenghi, Matteo Gorla, Riccardo Colombo, Antonio Bedogni, Francesco |
author_sort | Testa, Luca |
collection | PubMed |
description | BACKGROUND: The use of embolic protection devices (EPD) may theoretically reduce the occurrence of cerebral embolic lesions during transcatheter aortic valve implantation. Available evidence from single studies is inconclusive. The aim of the present meta‐analysis was to assess the safety and efficacy profile of current EPD. METHODS AND RESULTS: Major medical databases were searched up to December 2017 for studies that evaluated patients undergoing transcatheter aortic valve implantation with or without EPD. End points of interest were 30‐day mortality, 30‐day stroke, the total number of new lesions, the ischemic volume per lesion, and the total volume of lesions. Eight studies involving 1285 patients were included. The EPD delivery success rate was reported in all studies and was achieved in 94.5% of patients. The use of EPD was not associated with significant differences in terms of 30‐day mortality (odds ratio 0.43 [0.18–1.05], P=0.3) but it was associated with a lower rate of 30‐day stroke (odds ratio 0.55 [0.31–0.98], P=0.04). No differences were detected with respect to the number of new lesions (standardized mean difference −0.19 [−0.71 to 0.34], P=0.49). The use of EPD was associated with a significantly smaller ischemic volume per lesion (standardized mean difference, −0.52 [−0.85 to −0.20], P=0.002) and smaller total volume of lesions (standardized mean difference, −0.23 [−0.42 to −0.03], P=0.02). CONCLUSIONS: The use of EPD is not associated with a reduced rate of mortality and new ischemic cerebral lesions. The use of EPD during transcatheter aortic valve implantation seems to be associated with a lower 30‐day stroke rate, although this result is driven by a single nonrandomized study. The use of EPD is associated with a smaller volume of ischemic lesions, and smaller total volume of ischemic lesions. |
format | Online Article Text |
id | pubmed-6015324 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-60153242018-07-05 Cerebral Protection During Transcatheter Aortic Valve Implantation: An Updated Systematic Review and Meta‐Analysis Testa, Luca Latib, Azeem Casenghi, Matteo Gorla, Riccardo Colombo, Antonio Bedogni, Francesco J Am Heart Assoc Systematic Review and Meta‐Analysis BACKGROUND: The use of embolic protection devices (EPD) may theoretically reduce the occurrence of cerebral embolic lesions during transcatheter aortic valve implantation. Available evidence from single studies is inconclusive. The aim of the present meta‐analysis was to assess the safety and efficacy profile of current EPD. METHODS AND RESULTS: Major medical databases were searched up to December 2017 for studies that evaluated patients undergoing transcatheter aortic valve implantation with or without EPD. End points of interest were 30‐day mortality, 30‐day stroke, the total number of new lesions, the ischemic volume per lesion, and the total volume of lesions. Eight studies involving 1285 patients were included. The EPD delivery success rate was reported in all studies and was achieved in 94.5% of patients. The use of EPD was not associated with significant differences in terms of 30‐day mortality (odds ratio 0.43 [0.18–1.05], P=0.3) but it was associated with a lower rate of 30‐day stroke (odds ratio 0.55 [0.31–0.98], P=0.04). No differences were detected with respect to the number of new lesions (standardized mean difference −0.19 [−0.71 to 0.34], P=0.49). The use of EPD was associated with a significantly smaller ischemic volume per lesion (standardized mean difference, −0.52 [−0.85 to −0.20], P=0.002) and smaller total volume of lesions (standardized mean difference, −0.23 [−0.42 to −0.03], P=0.02). CONCLUSIONS: The use of EPD is not associated with a reduced rate of mortality and new ischemic cerebral lesions. The use of EPD during transcatheter aortic valve implantation seems to be associated with a lower 30‐day stroke rate, although this result is driven by a single nonrandomized study. The use of EPD is associated with a smaller volume of ischemic lesions, and smaller total volume of ischemic lesions. John Wiley and Sons Inc. 2018-05-04 /pmc/articles/PMC6015324/ /pubmed/29728369 http://dx.doi.org/10.1161/JAHA.117.008463 Text en © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley. This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Systematic Review and Meta‐Analysis Testa, Luca Latib, Azeem Casenghi, Matteo Gorla, Riccardo Colombo, Antonio Bedogni, Francesco Cerebral Protection During Transcatheter Aortic Valve Implantation: An Updated Systematic Review and Meta‐Analysis |
title | Cerebral Protection During Transcatheter Aortic Valve Implantation: An Updated Systematic Review and Meta‐Analysis |
title_full | Cerebral Protection During Transcatheter Aortic Valve Implantation: An Updated Systematic Review and Meta‐Analysis |
title_fullStr | Cerebral Protection During Transcatheter Aortic Valve Implantation: An Updated Systematic Review and Meta‐Analysis |
title_full_unstemmed | Cerebral Protection During Transcatheter Aortic Valve Implantation: An Updated Systematic Review and Meta‐Analysis |
title_short | Cerebral Protection During Transcatheter Aortic Valve Implantation: An Updated Systematic Review and Meta‐Analysis |
title_sort | cerebral protection during transcatheter aortic valve implantation: an updated systematic review and meta‐analysis |
topic | Systematic Review and Meta‐Analysis |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6015324/ https://www.ncbi.nlm.nih.gov/pubmed/29728369 http://dx.doi.org/10.1161/JAHA.117.008463 |
work_keys_str_mv | AT testaluca cerebralprotectionduringtranscatheteraorticvalveimplantationanupdatedsystematicreviewandmetaanalysis AT latibazeem cerebralprotectionduringtranscatheteraorticvalveimplantationanupdatedsystematicreviewandmetaanalysis AT casenghimatteo cerebralprotectionduringtranscatheteraorticvalveimplantationanupdatedsystematicreviewandmetaanalysis AT gorlariccardo cerebralprotectionduringtranscatheteraorticvalveimplantationanupdatedsystematicreviewandmetaanalysis AT colomboantonio cerebralprotectionduringtranscatheteraorticvalveimplantationanupdatedsystematicreviewandmetaanalysis AT bedognifrancesco cerebralprotectionduringtranscatheteraorticvalveimplantationanupdatedsystematicreviewandmetaanalysis |