Cargando…

Contact‐Free Screening of Atrial Fibrillation by a Smartphone Using Facial Pulsatile Photoplethysmographic Signals

BACKGROUND: We aimed to evaluate a novel method of atrial fibrillation (AF) screening using an iPhone camera to detect and analyze photoplethysmographic signals from the face without physical contact by extracting subtle beat‐to‐beat variations of skin color that reflect the cardiac pulsatile signal...

Descripción completa

Detalles Bibliográficos
Autores principales: Yan, Bryan P., Lai, William H. S., Chan, Christy K. Y., Chan, Stephen Chun‐Hin, Chan, Lok‐Hei, Lam, Ka‐Ming, Lau, Ho‐Wang, Ng, Chak‐Ming, Tai, Lok‐Yin, Yip, Kin‐Wai, To, Olivia T. L., Freedman, Ben, Poh, Yukkee C., Poh, Ming‐Zher
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6015414/
https://www.ncbi.nlm.nih.gov/pubmed/29622592
http://dx.doi.org/10.1161/JAHA.118.008585
_version_ 1783334407576223744
author Yan, Bryan P.
Lai, William H. S.
Chan, Christy K. Y.
Chan, Stephen Chun‐Hin
Chan, Lok‐Hei
Lam, Ka‐Ming
Lau, Ho‐Wang
Ng, Chak‐Ming
Tai, Lok‐Yin
Yip, Kin‐Wai
To, Olivia T. L.
Freedman, Ben
Poh, Yukkee C.
Poh, Ming‐Zher
author_facet Yan, Bryan P.
Lai, William H. S.
Chan, Christy K. Y.
Chan, Stephen Chun‐Hin
Chan, Lok‐Hei
Lam, Ka‐Ming
Lau, Ho‐Wang
Ng, Chak‐Ming
Tai, Lok‐Yin
Yip, Kin‐Wai
To, Olivia T. L.
Freedman, Ben
Poh, Yukkee C.
Poh, Ming‐Zher
author_sort Yan, Bryan P.
collection PubMed
description BACKGROUND: We aimed to evaluate a novel method of atrial fibrillation (AF) screening using an iPhone camera to detect and analyze photoplethysmographic signals from the face without physical contact by extracting subtle beat‐to‐beat variations of skin color that reflect the cardiac pulsatile signal. METHODS AND RESULTS: Patients admitted to the cardiology ward of the hospital for clinical reasons were recruited. Simultaneous facial and fingertip photoplethysmographic measurements were obtained from 217 hospital inpatients (mean age, 70.3±13.9 years; 71.4% men) facing the front camera and with an index finger covering the back camera of 2 independent iPhones before a 12‐lead ECG was recorded. Backdrop and background light intensity was monitored during signal acquisition. Three successive 20‐second (total, 60 seconds) recordings were acquired per patient and analyzed for heart rate regularity by Cardiio Rhythm (Cardiio Inc, Cambridge, MA) smartphone application. Pulse irregularity in ≥1 photoplethysmographic readings or 3 uninterpretable photoplethysmographic readings were considered a positive AF screening result. AF was present on 12‐lead ECG in 34.6% (n=75/217) patients. The Cardiio Rhythm facial photoplethysmographic application demonstrated high sensitivity (95%; 95% confidence interval, 87%–98%) and specificity (96%; 95% confidence interval, 91%–98%) in discriminating AF from sinus rhythm compared with 12‐lead ECG. The positive and negative predictive values were 92% (95% confidence interval, 84%–96%) and 97% (95% confidence interval, 93%–99%), respectively. CONCLUSIONS: Detection of a facial photoplethysmographic signal to determine pulse irregularity attributable to AF is feasible. The Cardiio Rhythm smartphone application showed high sensitivity and specificity, with low negative likelihood ratio for AF from facial photoplethysmographic signals. The convenience of a contact‐free approach is attractive for community screening and has the potential to be useful for distant AF screening.
format Online
Article
Text
id pubmed-6015414
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-60154142018-07-05 Contact‐Free Screening of Atrial Fibrillation by a Smartphone Using Facial Pulsatile Photoplethysmographic Signals Yan, Bryan P. Lai, William H. S. Chan, Christy K. Y. Chan, Stephen Chun‐Hin Chan, Lok‐Hei Lam, Ka‐Ming Lau, Ho‐Wang Ng, Chak‐Ming Tai, Lok‐Yin Yip, Kin‐Wai To, Olivia T. L. Freedman, Ben Poh, Yukkee C. Poh, Ming‐Zher J Am Heart Assoc Original Research BACKGROUND: We aimed to evaluate a novel method of atrial fibrillation (AF) screening using an iPhone camera to detect and analyze photoplethysmographic signals from the face without physical contact by extracting subtle beat‐to‐beat variations of skin color that reflect the cardiac pulsatile signal. METHODS AND RESULTS: Patients admitted to the cardiology ward of the hospital for clinical reasons were recruited. Simultaneous facial and fingertip photoplethysmographic measurements were obtained from 217 hospital inpatients (mean age, 70.3±13.9 years; 71.4% men) facing the front camera and with an index finger covering the back camera of 2 independent iPhones before a 12‐lead ECG was recorded. Backdrop and background light intensity was monitored during signal acquisition. Three successive 20‐second (total, 60 seconds) recordings were acquired per patient and analyzed for heart rate regularity by Cardiio Rhythm (Cardiio Inc, Cambridge, MA) smartphone application. Pulse irregularity in ≥1 photoplethysmographic readings or 3 uninterpretable photoplethysmographic readings were considered a positive AF screening result. AF was present on 12‐lead ECG in 34.6% (n=75/217) patients. The Cardiio Rhythm facial photoplethysmographic application demonstrated high sensitivity (95%; 95% confidence interval, 87%–98%) and specificity (96%; 95% confidence interval, 91%–98%) in discriminating AF from sinus rhythm compared with 12‐lead ECG. The positive and negative predictive values were 92% (95% confidence interval, 84%–96%) and 97% (95% confidence interval, 93%–99%), respectively. CONCLUSIONS: Detection of a facial photoplethysmographic signal to determine pulse irregularity attributable to AF is feasible. The Cardiio Rhythm smartphone application showed high sensitivity and specificity, with low negative likelihood ratio for AF from facial photoplethysmographic signals. The convenience of a contact‐free approach is attractive for community screening and has the potential to be useful for distant AF screening. John Wiley and Sons Inc. 2018-04-05 /pmc/articles/PMC6015414/ /pubmed/29622592 http://dx.doi.org/10.1161/JAHA.118.008585 Text en © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley. This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Original Research
Yan, Bryan P.
Lai, William H. S.
Chan, Christy K. Y.
Chan, Stephen Chun‐Hin
Chan, Lok‐Hei
Lam, Ka‐Ming
Lau, Ho‐Wang
Ng, Chak‐Ming
Tai, Lok‐Yin
Yip, Kin‐Wai
To, Olivia T. L.
Freedman, Ben
Poh, Yukkee C.
Poh, Ming‐Zher
Contact‐Free Screening of Atrial Fibrillation by a Smartphone Using Facial Pulsatile Photoplethysmographic Signals
title Contact‐Free Screening of Atrial Fibrillation by a Smartphone Using Facial Pulsatile Photoplethysmographic Signals
title_full Contact‐Free Screening of Atrial Fibrillation by a Smartphone Using Facial Pulsatile Photoplethysmographic Signals
title_fullStr Contact‐Free Screening of Atrial Fibrillation by a Smartphone Using Facial Pulsatile Photoplethysmographic Signals
title_full_unstemmed Contact‐Free Screening of Atrial Fibrillation by a Smartphone Using Facial Pulsatile Photoplethysmographic Signals
title_short Contact‐Free Screening of Atrial Fibrillation by a Smartphone Using Facial Pulsatile Photoplethysmographic Signals
title_sort contact‐free screening of atrial fibrillation by a smartphone using facial pulsatile photoplethysmographic signals
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6015414/
https://www.ncbi.nlm.nih.gov/pubmed/29622592
http://dx.doi.org/10.1161/JAHA.118.008585
work_keys_str_mv AT yanbryanp contactfreescreeningofatrialfibrillationbyasmartphoneusingfacialpulsatilephotoplethysmographicsignals
AT laiwilliamhs contactfreescreeningofatrialfibrillationbyasmartphoneusingfacialpulsatilephotoplethysmographicsignals
AT chanchristyky contactfreescreeningofatrialfibrillationbyasmartphoneusingfacialpulsatilephotoplethysmographicsignals
AT chanstephenchunhin contactfreescreeningofatrialfibrillationbyasmartphoneusingfacialpulsatilephotoplethysmographicsignals
AT chanlokhei contactfreescreeningofatrialfibrillationbyasmartphoneusingfacialpulsatilephotoplethysmographicsignals
AT lamkaming contactfreescreeningofatrialfibrillationbyasmartphoneusingfacialpulsatilephotoplethysmographicsignals
AT lauhowang contactfreescreeningofatrialfibrillationbyasmartphoneusingfacialpulsatilephotoplethysmographicsignals
AT ngchakming contactfreescreeningofatrialfibrillationbyasmartphoneusingfacialpulsatilephotoplethysmographicsignals
AT tailokyin contactfreescreeningofatrialfibrillationbyasmartphoneusingfacialpulsatilephotoplethysmographicsignals
AT yipkinwai contactfreescreeningofatrialfibrillationbyasmartphoneusingfacialpulsatilephotoplethysmographicsignals
AT tooliviatl contactfreescreeningofatrialfibrillationbyasmartphoneusingfacialpulsatilephotoplethysmographicsignals
AT freedmanben contactfreescreeningofatrialfibrillationbyasmartphoneusingfacialpulsatilephotoplethysmographicsignals
AT pohyukkeec contactfreescreeningofatrialfibrillationbyasmartphoneusingfacialpulsatilephotoplethysmographicsignals
AT pohmingzher contactfreescreeningofatrialfibrillationbyasmartphoneusingfacialpulsatilephotoplethysmographicsignals