Is Ahmed Glaucoma Valve Consistent in Performance?
PURPOSE: To investigate the mechanism of action and consistency in flow characteristics of the Ahmed glaucoma valve (AGV) under simulated physiological conditions in-vitro and to evaluate whether resistance during priming has any effect on performance of the device. METHODS: Each newly opened AGV de...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Association for Research in Vision and Ophthalmology
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6016431/ https://www.ncbi.nlm.nih.gov/pubmed/29946493 http://dx.doi.org/10.1167/tvst.7.3.19 |
_version_ | 1783334570037346304 |
---|---|
author | Choudhari, Nikhil S. Badakere, Swathi Vallabh Richhariya, Ashutosh Chittajallu, Sai Naga Sri Harsha Senthil, Sirisha Garudadri, Chandra Sekhar |
author_facet | Choudhari, Nikhil S. Badakere, Swathi Vallabh Richhariya, Ashutosh Chittajallu, Sai Naga Sri Harsha Senthil, Sirisha Garudadri, Chandra Sekhar |
author_sort | Choudhari, Nikhil S. |
collection | PubMed |
description | PURPOSE: To investigate the mechanism of action and consistency in flow characteristics of the Ahmed glaucoma valve (AGV) under simulated physiological conditions in-vitro and to evaluate whether resistance during priming has any effect on performance of the device. METHODS: Each newly opened AGV device was connected to a digital manometer and was primed with normal saline. The device was then placed in a saline bath and connected to an open manometer, a digital manometer, and an infusion pump. Saline was infused at a rate of 3 μL/min for 24 hours. Digital manometer readings were recorded at 4 Hz. RESULTS: Data obtained from 9 devices are presented as medians (ranges). The priming pressure was 1130 (835, 1625) mm Hg. Pressure versus time curves showed two distinct phases; transient and steady phases. The transient phase peak pressure was 24 (13, 45) mm Hg. In the steady phase, opening and closing pressures were 13 (10, 17) and 7 (4, 9) mm Hg, respectively; the valve leaflets briefly opened every 73.9 (51, 76.6) minutes and the fluctuation of pressure (difference between opening and closing pressures) was 6 (3, 9) mm Hg. The Spearman correlation coefficient between priming and opening and priming and closing pressure was ρ = −0.13 (P = 0.72) and ρ = −0.36 (P = 0.33), respectively. CONCLUSIONS: The device showed functionality like a valve. The resistance during priming did not affect opening and closing pressures of the AGV. This study showed variable in vitro performance of the AGV. TRANSLATIONAL RELEVANCE: These laboratory findings might, at least partly, explain the variability in the clinical outcome of the device. |
format | Online Article Text |
id | pubmed-6016431 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | The Association for Research in Vision and Ophthalmology |
record_format | MEDLINE/PubMed |
spelling | pubmed-60164312018-06-26 Is Ahmed Glaucoma Valve Consistent in Performance? Choudhari, Nikhil S. Badakere, Swathi Vallabh Richhariya, Ashutosh Chittajallu, Sai Naga Sri Harsha Senthil, Sirisha Garudadri, Chandra Sekhar Transl Vis Sci Technol Articles PURPOSE: To investigate the mechanism of action and consistency in flow characteristics of the Ahmed glaucoma valve (AGV) under simulated physiological conditions in-vitro and to evaluate whether resistance during priming has any effect on performance of the device. METHODS: Each newly opened AGV device was connected to a digital manometer and was primed with normal saline. The device was then placed in a saline bath and connected to an open manometer, a digital manometer, and an infusion pump. Saline was infused at a rate of 3 μL/min for 24 hours. Digital manometer readings were recorded at 4 Hz. RESULTS: Data obtained from 9 devices are presented as medians (ranges). The priming pressure was 1130 (835, 1625) mm Hg. Pressure versus time curves showed two distinct phases; transient and steady phases. The transient phase peak pressure was 24 (13, 45) mm Hg. In the steady phase, opening and closing pressures were 13 (10, 17) and 7 (4, 9) mm Hg, respectively; the valve leaflets briefly opened every 73.9 (51, 76.6) minutes and the fluctuation of pressure (difference between opening and closing pressures) was 6 (3, 9) mm Hg. The Spearman correlation coefficient between priming and opening and priming and closing pressure was ρ = −0.13 (P = 0.72) and ρ = −0.36 (P = 0.33), respectively. CONCLUSIONS: The device showed functionality like a valve. The resistance during priming did not affect opening and closing pressures of the AGV. This study showed variable in vitro performance of the AGV. TRANSLATIONAL RELEVANCE: These laboratory findings might, at least partly, explain the variability in the clinical outcome of the device. The Association for Research in Vision and Ophthalmology 2018-06-22 /pmc/articles/PMC6016431/ /pubmed/29946493 http://dx.doi.org/10.1167/tvst.7.3.19 Text en Copyright 2018 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. |
spellingShingle | Articles Choudhari, Nikhil S. Badakere, Swathi Vallabh Richhariya, Ashutosh Chittajallu, Sai Naga Sri Harsha Senthil, Sirisha Garudadri, Chandra Sekhar Is Ahmed Glaucoma Valve Consistent in Performance? |
title | Is Ahmed Glaucoma Valve Consistent in Performance? |
title_full | Is Ahmed Glaucoma Valve Consistent in Performance? |
title_fullStr | Is Ahmed Glaucoma Valve Consistent in Performance? |
title_full_unstemmed | Is Ahmed Glaucoma Valve Consistent in Performance? |
title_short | Is Ahmed Glaucoma Valve Consistent in Performance? |
title_sort | is ahmed glaucoma valve consistent in performance? |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6016431/ https://www.ncbi.nlm.nih.gov/pubmed/29946493 http://dx.doi.org/10.1167/tvst.7.3.19 |
work_keys_str_mv | AT choudharinikhils isahmedglaucomavalveconsistentinperformance AT badakereswathivallabh isahmedglaucomavalveconsistentinperformance AT richhariyaashutosh isahmedglaucomavalveconsistentinperformance AT chittajallusainagasriharsha isahmedglaucomavalveconsistentinperformance AT senthilsirisha isahmedglaucomavalveconsistentinperformance AT garudadrichandrasekhar isahmedglaucomavalveconsistentinperformance |