Effects of irregular respiratory motion on the positioning accuracy of moving target with free breathing cone-beam computerized tomography

For positioning a moving target, a maximum intensity projection (MIP) or average intensity projection (AIP) image derived from 4DCT is often used as the reference image which is matched to free breathing cone-beam CT (FBCBCT) before treatment. This method can be highly accurate if the respiratory mo...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Xiang, Li, Tianfang, Yorke, Ellen, Mageras, Gig, Tang, Xiaoli, Chan, Maria, Xiong, Weijun, Reyngold, Marsha, Gewanter, Richard, Wu, Abraham, Cuaron, John, Hunt, Margie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6016851/
https://www.ncbi.nlm.nih.gov/pubmed/29951344
http://dx.doi.org/10.4236/ijmpcero.2018.72015
_version_ 1783334617264160768
author Li, Xiang
Li, Tianfang
Yorke, Ellen
Mageras, Gig
Tang, Xiaoli
Chan, Maria
Xiong, Weijun
Reyngold, Marsha
Gewanter, Richard
Wu, Abraham
Cuaron, John
Hunt, Margie
author_facet Li, Xiang
Li, Tianfang
Yorke, Ellen
Mageras, Gig
Tang, Xiaoli
Chan, Maria
Xiong, Weijun
Reyngold, Marsha
Gewanter, Richard
Wu, Abraham
Cuaron, John
Hunt, Margie
author_sort Li, Xiang
collection PubMed
description For positioning a moving target, a maximum intensity projection (MIP) or average intensity projection (AIP) image derived from 4DCT is often used as the reference image which is matched to free breathing cone-beam CT (FBCBCT) before treatment. This method can be highly accurate if the respiratory motion of the patient is stable. However, a patient’s breathing pattern is often irregular. The purpose of this study is to investigate the effects of irregular respiration on positioning accuracy for a moving target aligned with FBCBCT. Nine patients’ respiratory motion curves were selected to drive a Quasar motion phantom with one embedded cubic and two spherical targets. A 4DCT of the phantom was acquired on a CT scanner (Philips Brilliance 16) equipped with a Varian RPM system. The phase binned 4DCT images and the corresponding MIP and AIP images were transferred into Eclipse for analysis. FBCBCTs of the phantom driven by the same respiratory curves were also acquired on a Varian TrueBeam and fused such that both CBCT and MIP/AIP images share the same target zero positions. The sphere and cube volumes and centroid differences (alignment error) determined by MIP, AIP and FBCBCT images were calculated, respectively. Compared to the volume determined by MIP, the volumes of the cube, large sphere, and small sphere in AIP and FBCBCT images were smaller. The alignment errors for the cube, large sphere and small sphere with center to center matches between MIP and FBCBCT were 2.5 ± 1.8mm, 2.4±2.1 mm, and 3.8±2.8 mm, and the alignment errors between AIP and FBCBCT were 0.5±1.1mm, 0.3±0.8mm, and 1.8±2.0 mm, respectively. AIP images appear to be superior reference images to MIP images. However, irregular respiratory pattern could compromise the positioning accuracy, especially for smaller targets.
format Online
Article
Text
id pubmed-6016851
institution National Center for Biotechnology Information
language English
publishDate 2018
record_format MEDLINE/PubMed
spelling pubmed-60168512018-06-25 Effects of irregular respiratory motion on the positioning accuracy of moving target with free breathing cone-beam computerized tomography Li, Xiang Li, Tianfang Yorke, Ellen Mageras, Gig Tang, Xiaoli Chan, Maria Xiong, Weijun Reyngold, Marsha Gewanter, Richard Wu, Abraham Cuaron, John Hunt, Margie Int J Med Phys Clin Eng Radiat Oncol Article For positioning a moving target, a maximum intensity projection (MIP) or average intensity projection (AIP) image derived from 4DCT is often used as the reference image which is matched to free breathing cone-beam CT (FBCBCT) before treatment. This method can be highly accurate if the respiratory motion of the patient is stable. However, a patient’s breathing pattern is often irregular. The purpose of this study is to investigate the effects of irregular respiration on positioning accuracy for a moving target aligned with FBCBCT. Nine patients’ respiratory motion curves were selected to drive a Quasar motion phantom with one embedded cubic and two spherical targets. A 4DCT of the phantom was acquired on a CT scanner (Philips Brilliance 16) equipped with a Varian RPM system. The phase binned 4DCT images and the corresponding MIP and AIP images were transferred into Eclipse for analysis. FBCBCTs of the phantom driven by the same respiratory curves were also acquired on a Varian TrueBeam and fused such that both CBCT and MIP/AIP images share the same target zero positions. The sphere and cube volumes and centroid differences (alignment error) determined by MIP, AIP and FBCBCT images were calculated, respectively. Compared to the volume determined by MIP, the volumes of the cube, large sphere, and small sphere in AIP and FBCBCT images were smaller. The alignment errors for the cube, large sphere and small sphere with center to center matches between MIP and FBCBCT were 2.5 ± 1.8mm, 2.4±2.1 mm, and 3.8±2.8 mm, and the alignment errors between AIP and FBCBCT were 0.5±1.1mm, 0.3±0.8mm, and 1.8±2.0 mm, respectively. AIP images appear to be superior reference images to MIP images. However, irregular respiratory pattern could compromise the positioning accuracy, especially for smaller targets. 2018-05-08 2018-05 /pmc/articles/PMC6016851/ /pubmed/29951344 http://dx.doi.org/10.4236/ijmpcero.2018.72015 Text en This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Li, Xiang
Li, Tianfang
Yorke, Ellen
Mageras, Gig
Tang, Xiaoli
Chan, Maria
Xiong, Weijun
Reyngold, Marsha
Gewanter, Richard
Wu, Abraham
Cuaron, John
Hunt, Margie
Effects of irregular respiratory motion on the positioning accuracy of moving target with free breathing cone-beam computerized tomography
title Effects of irregular respiratory motion on the positioning accuracy of moving target with free breathing cone-beam computerized tomography
title_full Effects of irregular respiratory motion on the positioning accuracy of moving target with free breathing cone-beam computerized tomography
title_fullStr Effects of irregular respiratory motion on the positioning accuracy of moving target with free breathing cone-beam computerized tomography
title_full_unstemmed Effects of irregular respiratory motion on the positioning accuracy of moving target with free breathing cone-beam computerized tomography
title_short Effects of irregular respiratory motion on the positioning accuracy of moving target with free breathing cone-beam computerized tomography
title_sort effects of irregular respiratory motion on the positioning accuracy of moving target with free breathing cone-beam computerized tomography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6016851/
https://www.ncbi.nlm.nih.gov/pubmed/29951344
http://dx.doi.org/10.4236/ijmpcero.2018.72015
work_keys_str_mv AT lixiang effectsofirregularrespiratorymotiononthepositioningaccuracyofmovingtargetwithfreebreathingconebeamcomputerizedtomography
AT litianfang effectsofirregularrespiratorymotiononthepositioningaccuracyofmovingtargetwithfreebreathingconebeamcomputerizedtomography
AT yorkeellen effectsofirregularrespiratorymotiononthepositioningaccuracyofmovingtargetwithfreebreathingconebeamcomputerizedtomography
AT magerasgig effectsofirregularrespiratorymotiononthepositioningaccuracyofmovingtargetwithfreebreathingconebeamcomputerizedtomography
AT tangxiaoli effectsofirregularrespiratorymotiononthepositioningaccuracyofmovingtargetwithfreebreathingconebeamcomputerizedtomography
AT chanmaria effectsofirregularrespiratorymotiononthepositioningaccuracyofmovingtargetwithfreebreathingconebeamcomputerizedtomography
AT xiongweijun effectsofirregularrespiratorymotiononthepositioningaccuracyofmovingtargetwithfreebreathingconebeamcomputerizedtomography
AT reyngoldmarsha effectsofirregularrespiratorymotiononthepositioningaccuracyofmovingtargetwithfreebreathingconebeamcomputerizedtomography
AT gewanterrichard effectsofirregularrespiratorymotiononthepositioningaccuracyofmovingtargetwithfreebreathingconebeamcomputerizedtomography
AT wuabraham effectsofirregularrespiratorymotiononthepositioningaccuracyofmovingtargetwithfreebreathingconebeamcomputerizedtomography
AT cuaronjohn effectsofirregularrespiratorymotiononthepositioningaccuracyofmovingtargetwithfreebreathingconebeamcomputerizedtomography
AT huntmargie effectsofirregularrespiratorymotiononthepositioningaccuracyofmovingtargetwithfreebreathingconebeamcomputerizedtomography