Cargando…

Fast and Simple Analytical Method for Direct Determination of Total Chlorine Content in Polyglycerol by ICP-MS

The fast and simple method for total chlorine determination in polyglycerols using low resolution inductively coupled plasma mass spectrometry (ICP-MS) without the need for additional equipment and time-consuming sample decomposition was evaluated. Linear calibration curve for (35)Cl isotope in the...

Descripción completa

Detalles Bibliográficos
Autores principales: Jakóbik-Kolon, Agata, Milewski, Andrzej, Dydo, Piotr, Witczak, Magdalena, Bok-Badura, Joanna
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6017008/
https://www.ncbi.nlm.nih.gov/pubmed/29473851
http://dx.doi.org/10.3390/molecules23020487
_version_ 1783334652958736384
author Jakóbik-Kolon, Agata
Milewski, Andrzej
Dydo, Piotr
Witczak, Magdalena
Bok-Badura, Joanna
author_facet Jakóbik-Kolon, Agata
Milewski, Andrzej
Dydo, Piotr
Witczak, Magdalena
Bok-Badura, Joanna
author_sort Jakóbik-Kolon, Agata
collection PubMed
description The fast and simple method for total chlorine determination in polyglycerols using low resolution inductively coupled plasma mass spectrometry (ICP-MS) without the need for additional equipment and time-consuming sample decomposition was evaluated. Linear calibration curve for (35)Cl isotope in the concentration range 20–800 µg/L was observed. Limits of detection and quantification equaled to 15 µg/L and 44 µg/L, respectively. This corresponds to possibility of detection 3 µg/g and determination 9 µg/g of chlorine in polyglycerol using studied conditions (0.5% matrix-polyglycerol samples diluted or dissolved with water to an overall concentration of 0.5%). Matrix effects as well as the effect of chlorine origin have been evaluated. The presence of 0.5% (m/m) of matrix species similar to polyglycerol (polyethylene glycol—PEG) did not influence the chlorine determination for PEGs with average molecular weights (MW) up to 2000 Da. Good precision and accuracy of the chlorine content determination was achieved regardless on its origin (inorganic/organic). High analyte recovery level and low relative standard deviation values were observed for real polyglycerol samples spiked with chloride. Additionally, the Combustion Ion Chromatography System was used as a reference method. The results confirmed high accuracy and precision of the tested method.
format Online
Article
Text
id pubmed-6017008
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-60170082018-11-13 Fast and Simple Analytical Method for Direct Determination of Total Chlorine Content in Polyglycerol by ICP-MS Jakóbik-Kolon, Agata Milewski, Andrzej Dydo, Piotr Witczak, Magdalena Bok-Badura, Joanna Molecules Article The fast and simple method for total chlorine determination in polyglycerols using low resolution inductively coupled plasma mass spectrometry (ICP-MS) without the need for additional equipment and time-consuming sample decomposition was evaluated. Linear calibration curve for (35)Cl isotope in the concentration range 20–800 µg/L was observed. Limits of detection and quantification equaled to 15 µg/L and 44 µg/L, respectively. This corresponds to possibility of detection 3 µg/g and determination 9 µg/g of chlorine in polyglycerol using studied conditions (0.5% matrix-polyglycerol samples diluted or dissolved with water to an overall concentration of 0.5%). Matrix effects as well as the effect of chlorine origin have been evaluated. The presence of 0.5% (m/m) of matrix species similar to polyglycerol (polyethylene glycol—PEG) did not influence the chlorine determination for PEGs with average molecular weights (MW) up to 2000 Da. Good precision and accuracy of the chlorine content determination was achieved regardless on its origin (inorganic/organic). High analyte recovery level and low relative standard deviation values were observed for real polyglycerol samples spiked with chloride. Additionally, the Combustion Ion Chromatography System was used as a reference method. The results confirmed high accuracy and precision of the tested method. MDPI 2018-02-23 /pmc/articles/PMC6017008/ /pubmed/29473851 http://dx.doi.org/10.3390/molecules23020487 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Jakóbik-Kolon, Agata
Milewski, Andrzej
Dydo, Piotr
Witczak, Magdalena
Bok-Badura, Joanna
Fast and Simple Analytical Method for Direct Determination of Total Chlorine Content in Polyglycerol by ICP-MS
title Fast and Simple Analytical Method for Direct Determination of Total Chlorine Content in Polyglycerol by ICP-MS
title_full Fast and Simple Analytical Method for Direct Determination of Total Chlorine Content in Polyglycerol by ICP-MS
title_fullStr Fast and Simple Analytical Method for Direct Determination of Total Chlorine Content in Polyglycerol by ICP-MS
title_full_unstemmed Fast and Simple Analytical Method for Direct Determination of Total Chlorine Content in Polyglycerol by ICP-MS
title_short Fast and Simple Analytical Method for Direct Determination of Total Chlorine Content in Polyglycerol by ICP-MS
title_sort fast and simple analytical method for direct determination of total chlorine content in polyglycerol by icp-ms
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6017008/
https://www.ncbi.nlm.nih.gov/pubmed/29473851
http://dx.doi.org/10.3390/molecules23020487
work_keys_str_mv AT jakobikkolonagata fastandsimpleanalyticalmethodfordirectdeterminationoftotalchlorinecontentinpolyglycerolbyicpms
AT milewskiandrzej fastandsimpleanalyticalmethodfordirectdeterminationoftotalchlorinecontentinpolyglycerolbyicpms
AT dydopiotr fastandsimpleanalyticalmethodfordirectdeterminationoftotalchlorinecontentinpolyglycerolbyicpms
AT witczakmagdalena fastandsimpleanalyticalmethodfordirectdeterminationoftotalchlorinecontentinpolyglycerolbyicpms
AT bokbadurajoanna fastandsimpleanalyticalmethodfordirectdeterminationoftotalchlorinecontentinpolyglycerolbyicpms