Cargando…
Fast and Simple Analytical Method for Direct Determination of Total Chlorine Content in Polyglycerol by ICP-MS
The fast and simple method for total chlorine determination in polyglycerols using low resolution inductively coupled plasma mass spectrometry (ICP-MS) without the need for additional equipment and time-consuming sample decomposition was evaluated. Linear calibration curve for (35)Cl isotope in the...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6017008/ https://www.ncbi.nlm.nih.gov/pubmed/29473851 http://dx.doi.org/10.3390/molecules23020487 |
_version_ | 1783334652958736384 |
---|---|
author | Jakóbik-Kolon, Agata Milewski, Andrzej Dydo, Piotr Witczak, Magdalena Bok-Badura, Joanna |
author_facet | Jakóbik-Kolon, Agata Milewski, Andrzej Dydo, Piotr Witczak, Magdalena Bok-Badura, Joanna |
author_sort | Jakóbik-Kolon, Agata |
collection | PubMed |
description | The fast and simple method for total chlorine determination in polyglycerols using low resolution inductively coupled plasma mass spectrometry (ICP-MS) without the need for additional equipment and time-consuming sample decomposition was evaluated. Linear calibration curve for (35)Cl isotope in the concentration range 20–800 µg/L was observed. Limits of detection and quantification equaled to 15 µg/L and 44 µg/L, respectively. This corresponds to possibility of detection 3 µg/g and determination 9 µg/g of chlorine in polyglycerol using studied conditions (0.5% matrix-polyglycerol samples diluted or dissolved with water to an overall concentration of 0.5%). Matrix effects as well as the effect of chlorine origin have been evaluated. The presence of 0.5% (m/m) of matrix species similar to polyglycerol (polyethylene glycol—PEG) did not influence the chlorine determination for PEGs with average molecular weights (MW) up to 2000 Da. Good precision and accuracy of the chlorine content determination was achieved regardless on its origin (inorganic/organic). High analyte recovery level and low relative standard deviation values were observed for real polyglycerol samples spiked with chloride. Additionally, the Combustion Ion Chromatography System was used as a reference method. The results confirmed high accuracy and precision of the tested method. |
format | Online Article Text |
id | pubmed-6017008 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-60170082018-11-13 Fast and Simple Analytical Method for Direct Determination of Total Chlorine Content in Polyglycerol by ICP-MS Jakóbik-Kolon, Agata Milewski, Andrzej Dydo, Piotr Witczak, Magdalena Bok-Badura, Joanna Molecules Article The fast and simple method for total chlorine determination in polyglycerols using low resolution inductively coupled plasma mass spectrometry (ICP-MS) without the need for additional equipment and time-consuming sample decomposition was evaluated. Linear calibration curve for (35)Cl isotope in the concentration range 20–800 µg/L was observed. Limits of detection and quantification equaled to 15 µg/L and 44 µg/L, respectively. This corresponds to possibility of detection 3 µg/g and determination 9 µg/g of chlorine in polyglycerol using studied conditions (0.5% matrix-polyglycerol samples diluted or dissolved with water to an overall concentration of 0.5%). Matrix effects as well as the effect of chlorine origin have been evaluated. The presence of 0.5% (m/m) of matrix species similar to polyglycerol (polyethylene glycol—PEG) did not influence the chlorine determination for PEGs with average molecular weights (MW) up to 2000 Da. Good precision and accuracy of the chlorine content determination was achieved regardless on its origin (inorganic/organic). High analyte recovery level and low relative standard deviation values were observed for real polyglycerol samples spiked with chloride. Additionally, the Combustion Ion Chromatography System was used as a reference method. The results confirmed high accuracy and precision of the tested method. MDPI 2018-02-23 /pmc/articles/PMC6017008/ /pubmed/29473851 http://dx.doi.org/10.3390/molecules23020487 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Jakóbik-Kolon, Agata Milewski, Andrzej Dydo, Piotr Witczak, Magdalena Bok-Badura, Joanna Fast and Simple Analytical Method for Direct Determination of Total Chlorine Content in Polyglycerol by ICP-MS |
title | Fast and Simple Analytical Method for Direct Determination of Total Chlorine Content in Polyglycerol by ICP-MS |
title_full | Fast and Simple Analytical Method for Direct Determination of Total Chlorine Content in Polyglycerol by ICP-MS |
title_fullStr | Fast and Simple Analytical Method for Direct Determination of Total Chlorine Content in Polyglycerol by ICP-MS |
title_full_unstemmed | Fast and Simple Analytical Method for Direct Determination of Total Chlorine Content in Polyglycerol by ICP-MS |
title_short | Fast and Simple Analytical Method for Direct Determination of Total Chlorine Content in Polyglycerol by ICP-MS |
title_sort | fast and simple analytical method for direct determination of total chlorine content in polyglycerol by icp-ms |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6017008/ https://www.ncbi.nlm.nih.gov/pubmed/29473851 http://dx.doi.org/10.3390/molecules23020487 |
work_keys_str_mv | AT jakobikkolonagata fastandsimpleanalyticalmethodfordirectdeterminationoftotalchlorinecontentinpolyglycerolbyicpms AT milewskiandrzej fastandsimpleanalyticalmethodfordirectdeterminationoftotalchlorinecontentinpolyglycerolbyicpms AT dydopiotr fastandsimpleanalyticalmethodfordirectdeterminationoftotalchlorinecontentinpolyglycerolbyicpms AT witczakmagdalena fastandsimpleanalyticalmethodfordirectdeterminationoftotalchlorinecontentinpolyglycerolbyicpms AT bokbadurajoanna fastandsimpleanalyticalmethodfordirectdeterminationoftotalchlorinecontentinpolyglycerolbyicpms |