Cargando…

A Lateral Flow Strip Based Aptasensor for Detection of Ochratoxin A in Corn Samples

Ochratoxin A (OTA) is a mycotoxin identified as a contaminant in grains and wine throughout the world, and convenient, rapid and sensitive detection methods for OTA have been a long-felt need for food safety monitoring. Herein, we presented a new competitive format based lateral flow strip fluoresce...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Guilan, Zhu, Chao, Huang, Yafei, Yan, Jiao, Chen, Ailiang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6017962/
https://www.ncbi.nlm.nih.gov/pubmed/29385022
http://dx.doi.org/10.3390/molecules23020291
_version_ 1783334866200297472
author Zhang, Guilan
Zhu, Chao
Huang, Yafei
Yan, Jiao
Chen, Ailiang
author_facet Zhang, Guilan
Zhu, Chao
Huang, Yafei
Yan, Jiao
Chen, Ailiang
author_sort Zhang, Guilan
collection PubMed
description Ochratoxin A (OTA) is a mycotoxin identified as a contaminant in grains and wine throughout the world, and convenient, rapid and sensitive detection methods for OTA have been a long-felt need for food safety monitoring. Herein, we presented a new competitive format based lateral flow strip fluorescent aptasensor for one-step determination of OTA in corn samples. Briefly, biotin-cDNA was immobilized on the surface of a nitrocellulose filter on the test line. Without OTA, Cy5-labeled aptamer combined with complementary strands formed a stable double helix. In the presence of OTA, however, the Cy5-aptamer/OTA complexes were generated, and therefore less free aptamer was captured in the test zone, leading to an obvious decrease in fluorescent signals on the test line. The test strip showed an excellent linear relationship in the range from 1 ng·mL(−1) to 1000 ng·mL(−1) with the LOD of 0.40 ng·mL(−1), IC(15) value of 3.46 ng·mL(−1) and recoveries from 96.4% to 104.67% in spiked corn samples. Thus, the strip sensor developed in this study is an acceptable alternative for rapid detection of the OTA level in grain samples.
format Online
Article
Text
id pubmed-6017962
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-60179622018-11-13 A Lateral Flow Strip Based Aptasensor for Detection of Ochratoxin A in Corn Samples Zhang, Guilan Zhu, Chao Huang, Yafei Yan, Jiao Chen, Ailiang Molecules Article Ochratoxin A (OTA) is a mycotoxin identified as a contaminant in grains and wine throughout the world, and convenient, rapid and sensitive detection methods for OTA have been a long-felt need for food safety monitoring. Herein, we presented a new competitive format based lateral flow strip fluorescent aptasensor for one-step determination of OTA in corn samples. Briefly, biotin-cDNA was immobilized on the surface of a nitrocellulose filter on the test line. Without OTA, Cy5-labeled aptamer combined with complementary strands formed a stable double helix. In the presence of OTA, however, the Cy5-aptamer/OTA complexes were generated, and therefore less free aptamer was captured in the test zone, leading to an obvious decrease in fluorescent signals on the test line. The test strip showed an excellent linear relationship in the range from 1 ng·mL(−1) to 1000 ng·mL(−1) with the LOD of 0.40 ng·mL(−1), IC(15) value of 3.46 ng·mL(−1) and recoveries from 96.4% to 104.67% in spiked corn samples. Thus, the strip sensor developed in this study is an acceptable alternative for rapid detection of the OTA level in grain samples. MDPI 2018-01-31 /pmc/articles/PMC6017962/ /pubmed/29385022 http://dx.doi.org/10.3390/molecules23020291 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhang, Guilan
Zhu, Chao
Huang, Yafei
Yan, Jiao
Chen, Ailiang
A Lateral Flow Strip Based Aptasensor for Detection of Ochratoxin A in Corn Samples
title A Lateral Flow Strip Based Aptasensor for Detection of Ochratoxin A in Corn Samples
title_full A Lateral Flow Strip Based Aptasensor for Detection of Ochratoxin A in Corn Samples
title_fullStr A Lateral Flow Strip Based Aptasensor for Detection of Ochratoxin A in Corn Samples
title_full_unstemmed A Lateral Flow Strip Based Aptasensor for Detection of Ochratoxin A in Corn Samples
title_short A Lateral Flow Strip Based Aptasensor for Detection of Ochratoxin A in Corn Samples
title_sort lateral flow strip based aptasensor for detection of ochratoxin a in corn samples
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6017962/
https://www.ncbi.nlm.nih.gov/pubmed/29385022
http://dx.doi.org/10.3390/molecules23020291
work_keys_str_mv AT zhangguilan alateralflowstripbasedaptasensorfordetectionofochratoxinaincornsamples
AT zhuchao alateralflowstripbasedaptasensorfordetectionofochratoxinaincornsamples
AT huangyafei alateralflowstripbasedaptasensorfordetectionofochratoxinaincornsamples
AT yanjiao alateralflowstripbasedaptasensorfordetectionofochratoxinaincornsamples
AT chenailiang alateralflowstripbasedaptasensorfordetectionofochratoxinaincornsamples
AT zhangguilan lateralflowstripbasedaptasensorfordetectionofochratoxinaincornsamples
AT zhuchao lateralflowstripbasedaptasensorfordetectionofochratoxinaincornsamples
AT huangyafei lateralflowstripbasedaptasensorfordetectionofochratoxinaincornsamples
AT yanjiao lateralflowstripbasedaptasensorfordetectionofochratoxinaincornsamples
AT chenailiang lateralflowstripbasedaptasensorfordetectionofochratoxinaincornsamples