Cargando…
Excellent accuracy of ABC/2 volume formula compared to computer-assisted volumetric analysis of subdural hematomas
BACKGROUND: Subdural hematoma (SDH) is a common disease associated with high morbidity, which is becoming more prominent due to the increasing incidence. Decision for a surgical evacuation is made depending on the clinical appearance and the volume of SDH, wherefore it is important to have a simple...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6019668/ https://www.ncbi.nlm.nih.gov/pubmed/29944717 http://dx.doi.org/10.1371/journal.pone.0199809 |
Sumario: | BACKGROUND: Subdural hematoma (SDH) is a common disease associated with high morbidity, which is becoming more prominent due to the increasing incidence. Decision for a surgical evacuation is made depending on the clinical appearance and the volume of SDH, wherefore it is important to have a simple ‘bedside’ method to measure and compare the volume of SDH. OBJECTIVE: The aim of the study was to verify the accuracy of the simplified ABC/2 volumetric formula to determine a valuable tool for the clinical practice. METHODS: Preoperative CT-scans of 83 patients with SDHs were used for the computer-assisted volumetric measurement via BrainLab® as well as the ABC/2 volumetric measurement. A = largest length (anterior to posterior) of the SDH; B = maximum width (lateral to midline) 90° to A; C = maximum height (coronal plane or multiplication of slices) of the hematoma. These measurements were performed by two independent clinicians in a blinded fashion. Both volumes were compared by linear regression analysis of Pearson and Bland-Altman regression analysis. RESULTS: Among 100 SDHs, 53% were under an 47% were over 100cm(3) showing a well distribution of the hematoma sizes. There was an excellent correlation between computer-assisted volumetric measurement and ABC/2 (R(2) = 0.947, p<0.0001) and no undesirable deviation and trend were detected (p = 0.101; p = 0.777). A 95% tolerance region of the ratios of both methods was [0.805–1.201]. CONCLUSION: The ABC/2 method is a simple and fast bedside formula for the measurement of SDH volume in a timely manner without limited access through simple adaption, which may replace the computer-assisted volumetric measurement in the clinical and research area. Reason for the good accuracy seems to be the spherical form of SDH, which has a similarity to a half ellipsoid. |
---|