Cargando…
Dosimetric, Radiobiological and Secondary Cancer Risk Evaluation in Head-and-Neck Three-dimensional Conformal Radiation Therapy, Intensity-Modulated Radiation Therapy, and Volumetric Modulated Arc Therapy: A Phantom Study
This analysis estimated secondary cancer risks after volumetric modulated arc therapy (VMAT) and compared those risks to the risks associated with other modalities of head-and-neck (H&N) radiotherapy. Images of H&N anthropomorphic phantom were acquired with a computed tomography scanner and...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6020619/ https://www.ncbi.nlm.nih.gov/pubmed/29962691 http://dx.doi.org/10.4103/jmp.JMP_106_17 |
_version_ | 1783335336642871296 |
---|---|
author | Rehman, Jalil Ur Isa, Muhammad Ahmad, Nisar Nasar, Gulfam Asghar, H. M. Noor Ul Huda Khan Gilani, Zaheer Abbas Chow, James C. L. Afzal, Muhammad Ibbott, Geoffrey S. |
author_facet | Rehman, Jalil Ur Isa, Muhammad Ahmad, Nisar Nasar, Gulfam Asghar, H. M. Noor Ul Huda Khan Gilani, Zaheer Abbas Chow, James C. L. Afzal, Muhammad Ibbott, Geoffrey S. |
author_sort | Rehman, Jalil Ur |
collection | PubMed |
description | This analysis estimated secondary cancer risks after volumetric modulated arc therapy (VMAT) and compared those risks to the risks associated with other modalities of head-and-neck (H&N) radiotherapy. Images of H&N anthropomorphic phantom were acquired with a computed tomography scanner and exported via digital imaging and communications in medicine (DICOM) standards to a treatment planning system. Treatment plans were performed using a VMAT dual-arc technique, a nine-field intensity-modulated radiation therapy (IMRT) technique, and a four-field three-dimensional conformal therapy (3DCRT) technique. The prescription dose was 66.0 Gy for all three techniques, but to accommodate the range of dosimeter responses, we delivered a single dose of 6.60 Gy to the isocenter. The lifetime risk for secondary cancers was estimated according to National Council on Radiation Protection and Measurements (NCRP) Report 116. VMAT delivered the lowest maximum doses to esophagus (23 Gy), and normal brain (40 Gy). In comparison, maximum doses for 3DCRT were 74% and 40%, higher than those for VMAT for the esophagus, and normal brain, respectively. The normal tissue complication probability and equivalent uniform dose for the brain (2.1%, 0.9%, 0.8% and 3.8 Gy, 2.6 Gy, 2.3 Gy) and esophagus (4.2%, 0.7%, 0.4% and 3.7 Gy, 2.2 Gy, 1.8 Gy) were calculated for the 3DCRT, IMRT and VMAT respectively. Fractional esophagus OAR volumes receiving more than 20 Gy were 3.6% for VMAT, 23.6% for IMRT, and 100% for 3DCRT. The calculations for mean doses, NTCP, EUD and OAR volumes suggest that the risk of secondary cancer induction after VMAT is lower than after IMRT and 3DCRT. |
format | Online Article Text |
id | pubmed-6020619 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-60206192018-06-29 Dosimetric, Radiobiological and Secondary Cancer Risk Evaluation in Head-and-Neck Three-dimensional Conformal Radiation Therapy, Intensity-Modulated Radiation Therapy, and Volumetric Modulated Arc Therapy: A Phantom Study Rehman, Jalil Ur Isa, Muhammad Ahmad, Nisar Nasar, Gulfam Asghar, H. M. Noor Ul Huda Khan Gilani, Zaheer Abbas Chow, James C. L. Afzal, Muhammad Ibbott, Geoffrey S. J Med Phys Technical Note This analysis estimated secondary cancer risks after volumetric modulated arc therapy (VMAT) and compared those risks to the risks associated with other modalities of head-and-neck (H&N) radiotherapy. Images of H&N anthropomorphic phantom were acquired with a computed tomography scanner and exported via digital imaging and communications in medicine (DICOM) standards to a treatment planning system. Treatment plans were performed using a VMAT dual-arc technique, a nine-field intensity-modulated radiation therapy (IMRT) technique, and a four-field three-dimensional conformal therapy (3DCRT) technique. The prescription dose was 66.0 Gy for all three techniques, but to accommodate the range of dosimeter responses, we delivered a single dose of 6.60 Gy to the isocenter. The lifetime risk for secondary cancers was estimated according to National Council on Radiation Protection and Measurements (NCRP) Report 116. VMAT delivered the lowest maximum doses to esophagus (23 Gy), and normal brain (40 Gy). In comparison, maximum doses for 3DCRT were 74% and 40%, higher than those for VMAT for the esophagus, and normal brain, respectively. The normal tissue complication probability and equivalent uniform dose for the brain (2.1%, 0.9%, 0.8% and 3.8 Gy, 2.6 Gy, 2.3 Gy) and esophagus (4.2%, 0.7%, 0.4% and 3.7 Gy, 2.2 Gy, 1.8 Gy) were calculated for the 3DCRT, IMRT and VMAT respectively. Fractional esophagus OAR volumes receiving more than 20 Gy were 3.6% for VMAT, 23.6% for IMRT, and 100% for 3DCRT. The calculations for mean doses, NTCP, EUD and OAR volumes suggest that the risk of secondary cancer induction after VMAT is lower than after IMRT and 3DCRT. Medknow Publications & Media Pvt Ltd 2018 /pmc/articles/PMC6020619/ /pubmed/29962691 http://dx.doi.org/10.4103/jmp.JMP_106_17 Text en Copyright: © 2018 Journal of Medical Physics http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Technical Note Rehman, Jalil Ur Isa, Muhammad Ahmad, Nisar Nasar, Gulfam Asghar, H. M. Noor Ul Huda Khan Gilani, Zaheer Abbas Chow, James C. L. Afzal, Muhammad Ibbott, Geoffrey S. Dosimetric, Radiobiological and Secondary Cancer Risk Evaluation in Head-and-Neck Three-dimensional Conformal Radiation Therapy, Intensity-Modulated Radiation Therapy, and Volumetric Modulated Arc Therapy: A Phantom Study |
title | Dosimetric, Radiobiological and Secondary Cancer Risk Evaluation in Head-and-Neck Three-dimensional Conformal Radiation Therapy, Intensity-Modulated Radiation Therapy, and Volumetric Modulated Arc Therapy: A Phantom Study |
title_full | Dosimetric, Radiobiological and Secondary Cancer Risk Evaluation in Head-and-Neck Three-dimensional Conformal Radiation Therapy, Intensity-Modulated Radiation Therapy, and Volumetric Modulated Arc Therapy: A Phantom Study |
title_fullStr | Dosimetric, Radiobiological and Secondary Cancer Risk Evaluation in Head-and-Neck Three-dimensional Conformal Radiation Therapy, Intensity-Modulated Radiation Therapy, and Volumetric Modulated Arc Therapy: A Phantom Study |
title_full_unstemmed | Dosimetric, Radiobiological and Secondary Cancer Risk Evaluation in Head-and-Neck Three-dimensional Conformal Radiation Therapy, Intensity-Modulated Radiation Therapy, and Volumetric Modulated Arc Therapy: A Phantom Study |
title_short | Dosimetric, Radiobiological and Secondary Cancer Risk Evaluation in Head-and-Neck Three-dimensional Conformal Radiation Therapy, Intensity-Modulated Radiation Therapy, and Volumetric Modulated Arc Therapy: A Phantom Study |
title_sort | dosimetric, radiobiological and secondary cancer risk evaluation in head-and-neck three-dimensional conformal radiation therapy, intensity-modulated radiation therapy, and volumetric modulated arc therapy: a phantom study |
topic | Technical Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6020619/ https://www.ncbi.nlm.nih.gov/pubmed/29962691 http://dx.doi.org/10.4103/jmp.JMP_106_17 |
work_keys_str_mv | AT rehmanjalilur dosimetricradiobiologicalandsecondarycancerriskevaluationinheadandneckthreedimensionalconformalradiationtherapyintensitymodulatedradiationtherapyandvolumetricmodulatedarctherapyaphantomstudy AT isamuhammad dosimetricradiobiologicalandsecondarycancerriskevaluationinheadandneckthreedimensionalconformalradiationtherapyintensitymodulatedradiationtherapyandvolumetricmodulatedarctherapyaphantomstudy AT ahmadnisar dosimetricradiobiologicalandsecondarycancerriskevaluationinheadandneckthreedimensionalconformalradiationtherapyintensitymodulatedradiationtherapyandvolumetricmodulatedarctherapyaphantomstudy AT nasargulfam dosimetricradiobiologicalandsecondarycancerriskevaluationinheadandneckthreedimensionalconformalradiationtherapyintensitymodulatedradiationtherapyandvolumetricmodulatedarctherapyaphantomstudy AT asgharhmnoorulhudakhan dosimetricradiobiologicalandsecondarycancerriskevaluationinheadandneckthreedimensionalconformalradiationtherapyintensitymodulatedradiationtherapyandvolumetricmodulatedarctherapyaphantomstudy AT gilanizaheerabbas dosimetricradiobiologicalandsecondarycancerriskevaluationinheadandneckthreedimensionalconformalradiationtherapyintensitymodulatedradiationtherapyandvolumetricmodulatedarctherapyaphantomstudy AT chowjamescl dosimetricradiobiologicalandsecondarycancerriskevaluationinheadandneckthreedimensionalconformalradiationtherapyintensitymodulatedradiationtherapyandvolumetricmodulatedarctherapyaphantomstudy AT afzalmuhammad dosimetricradiobiologicalandsecondarycancerriskevaluationinheadandneckthreedimensionalconformalradiationtherapyintensitymodulatedradiationtherapyandvolumetricmodulatedarctherapyaphantomstudy AT ibbottgeoffreys dosimetricradiobiologicalandsecondarycancerriskevaluationinheadandneckthreedimensionalconformalradiationtherapyintensitymodulatedradiationtherapyandvolumetricmodulatedarctherapyaphantomstudy |