Cargando…
Patient-Specific Quality Assurance Protocol for Volumetric Modulated Arc Therapy using Dose Volume Histogram
A retrospective study was performed to explore the use of dose volume histogram (DVH) metrics in a patient-specific quality assurance protocol for volumetric modulated arc therapy (VMAT). Fourteen head and neck (HN) and ten brain patients treated with VMAT at the Launceston General Hospital were ret...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6020622/ https://www.ncbi.nlm.nih.gov/pubmed/29962689 http://dx.doi.org/10.4103/jmp.JMP_138_17 |
_version_ | 1783335337372680192 |
---|---|
author | Low, Christopher Toye, Warren Phung, Peter Huston, Christopher |
author_facet | Low, Christopher Toye, Warren Phung, Peter Huston, Christopher |
author_sort | Low, Christopher |
collection | PubMed |
description | A retrospective study was performed to explore the use of dose volume histogram (DVH) metrics in a patient-specific quality assurance protocol for volumetric modulated arc therapy (VMAT). Fourteen head and neck (HN) and ten brain patients treated with VMAT at the Launceston General Hospital were retrospectively analyzed using the new protocol to identify cases where patient dose errors exceed the established action levels that were not originally detected by either point dose and/or gamma index methods. The Sun Nuclear 3DVH software was used to estimate the dose delivered to the patient volume in terms of DVH dose errors. Thus, three different pretreatment verification methods were used to assess if a plan was considered acceptable. In two particular cases, the dose difference determined with point dose was above the established threshold, although it was found that this was due to the placement of the chamber in the phantom. In all cases, 3DVH confirmed that the dose delivered to target volumes (planning target volume – D(50%)) and to relevant organs at risk was within prescribed dose tolerances. This study has demonstrated the integration of DVH metrics into a VMAT PSQA protocol to provide clinically meaningful results that complement point dose and gamma index measurements. 3DVH should be regarded as an investigative tool that may be useful in diagnosing the cause of failed plans since it allows dose errors to be related to the patient anatomy. |
format | Online Article Text |
id | pubmed-6020622 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-60206222018-06-29 Patient-Specific Quality Assurance Protocol for Volumetric Modulated Arc Therapy using Dose Volume Histogram Low, Christopher Toye, Warren Phung, Peter Huston, Christopher J Med Phys Technical Note A retrospective study was performed to explore the use of dose volume histogram (DVH) metrics in a patient-specific quality assurance protocol for volumetric modulated arc therapy (VMAT). Fourteen head and neck (HN) and ten brain patients treated with VMAT at the Launceston General Hospital were retrospectively analyzed using the new protocol to identify cases where patient dose errors exceed the established action levels that were not originally detected by either point dose and/or gamma index methods. The Sun Nuclear 3DVH software was used to estimate the dose delivered to the patient volume in terms of DVH dose errors. Thus, three different pretreatment verification methods were used to assess if a plan was considered acceptable. In two particular cases, the dose difference determined with point dose was above the established threshold, although it was found that this was due to the placement of the chamber in the phantom. In all cases, 3DVH confirmed that the dose delivered to target volumes (planning target volume – D(50%)) and to relevant organs at risk was within prescribed dose tolerances. This study has demonstrated the integration of DVH metrics into a VMAT PSQA protocol to provide clinically meaningful results that complement point dose and gamma index measurements. 3DVH should be regarded as an investigative tool that may be useful in diagnosing the cause of failed plans since it allows dose errors to be related to the patient anatomy. Medknow Publications & Media Pvt Ltd 2018 /pmc/articles/PMC6020622/ /pubmed/29962689 http://dx.doi.org/10.4103/jmp.JMP_138_17 Text en Copyright: © 2018 Journal of Medical Physics http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Technical Note Low, Christopher Toye, Warren Phung, Peter Huston, Christopher Patient-Specific Quality Assurance Protocol for Volumetric Modulated Arc Therapy using Dose Volume Histogram |
title | Patient-Specific Quality Assurance Protocol for Volumetric Modulated Arc Therapy using Dose Volume Histogram |
title_full | Patient-Specific Quality Assurance Protocol for Volumetric Modulated Arc Therapy using Dose Volume Histogram |
title_fullStr | Patient-Specific Quality Assurance Protocol for Volumetric Modulated Arc Therapy using Dose Volume Histogram |
title_full_unstemmed | Patient-Specific Quality Assurance Protocol for Volumetric Modulated Arc Therapy using Dose Volume Histogram |
title_short | Patient-Specific Quality Assurance Protocol for Volumetric Modulated Arc Therapy using Dose Volume Histogram |
title_sort | patient-specific quality assurance protocol for volumetric modulated arc therapy using dose volume histogram |
topic | Technical Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6020622/ https://www.ncbi.nlm.nih.gov/pubmed/29962689 http://dx.doi.org/10.4103/jmp.JMP_138_17 |
work_keys_str_mv | AT lowchristopher patientspecificqualityassuranceprotocolforvolumetricmodulatedarctherapyusingdosevolumehistogram AT toyewarren patientspecificqualityassuranceprotocolforvolumetricmodulatedarctherapyusingdosevolumehistogram AT phungpeter patientspecificqualityassuranceprotocolforvolumetricmodulatedarctherapyusingdosevolumehistogram AT hustonchristopher patientspecificqualityassuranceprotocolforvolumetricmodulatedarctherapyusingdosevolumehistogram |