In vitro validation of a self-driving aortic-turbine venous-assist device for Fontan patients
BACKGROUND: Palliative repair of single ventricle defects involve a series of open-heart surgeries where a single-ventricle (Fontan) circulation is established. As the patient ages, this paradoxical circulation gradually fails, because of its high venous pressure levels. Reversal of the Fontan parad...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Mosby
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6021195/ https://www.ncbi.nlm.nih.gov/pubmed/29666009 http://dx.doi.org/10.1016/j.jtcvs.2018.02.088 |
_version_ | 1783335427401318400 |
---|---|
author | Pekkan, Kerem Aka, Ibrahim Basar Tutsak, Ece Ermek, Erhan Balim, Haldun Lazoglu, Ismail Turkoz, Riza |
author_facet | Pekkan, Kerem Aka, Ibrahim Basar Tutsak, Ece Ermek, Erhan Balim, Haldun Lazoglu, Ismail Turkoz, Riza |
author_sort | Pekkan, Kerem |
collection | PubMed |
description | BACKGROUND: Palliative repair of single ventricle defects involve a series of open-heart surgeries where a single-ventricle (Fontan) circulation is established. As the patient ages, this paradoxical circulation gradually fails, because of its high venous pressure levels. Reversal of the Fontan paradox requires an extra subpulmonic energy that can be provided through mechanical assist devices. The objective of this study was to evaluate the hemodynamic performance of a totally implantable integrated aortic-turbine venous-assist (iATVA) system, which does not need an external drive power and maintains low venous pressure chronically, for the Fontan circulation. METHODS: Blade designs of the co-rotating turbine and pump impellers were developed and 3 prototypes were manufactured. After verifying the single-ventricle physiology at a pulsatile in vitro circuit, the hemodynamic performance of the iATVA system was measured for pediatric and adult physiology, varying the aortic steal percentage and circuit configurations. The iATVA system was also tested at clinical off-design scenarios. RESULTS: The prototype iATVA devices operate at approximately 800 revolutions per minute and extract up to 10% systemic blood from the aorta to use this hydrodynamic energy to drive a blood turbine, which in turn drives a mixed-flow venous pump passively. By transferring part of the available energy from the single-ventricle outlet to the venous side, the iATVA system is able to generate up to approximately 5 mm Hg venous recovery while supplying the entire caval flow. CONCLUSIONS: Our experiments show that a totally implantable iATVA system is feasible, which will eliminate the need for external power for Fontan mechanical venous assist and combat gradual postoperative venous remodeling and Fontan failure. |
format | Online Article Text |
id | pubmed-6021195 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Mosby |
record_format | MEDLINE/PubMed |
spelling | pubmed-60211952018-07-01 In vitro validation of a self-driving aortic-turbine venous-assist device for Fontan patients Pekkan, Kerem Aka, Ibrahim Basar Tutsak, Ece Ermek, Erhan Balim, Haldun Lazoglu, Ismail Turkoz, Riza J Thorac Cardiovasc Surg Article BACKGROUND: Palliative repair of single ventricle defects involve a series of open-heart surgeries where a single-ventricle (Fontan) circulation is established. As the patient ages, this paradoxical circulation gradually fails, because of its high venous pressure levels. Reversal of the Fontan paradox requires an extra subpulmonic energy that can be provided through mechanical assist devices. The objective of this study was to evaluate the hemodynamic performance of a totally implantable integrated aortic-turbine venous-assist (iATVA) system, which does not need an external drive power and maintains low venous pressure chronically, for the Fontan circulation. METHODS: Blade designs of the co-rotating turbine and pump impellers were developed and 3 prototypes were manufactured. After verifying the single-ventricle physiology at a pulsatile in vitro circuit, the hemodynamic performance of the iATVA system was measured for pediatric and adult physiology, varying the aortic steal percentage and circuit configurations. The iATVA system was also tested at clinical off-design scenarios. RESULTS: The prototype iATVA devices operate at approximately 800 revolutions per minute and extract up to 10% systemic blood from the aorta to use this hydrodynamic energy to drive a blood turbine, which in turn drives a mixed-flow venous pump passively. By transferring part of the available energy from the single-ventricle outlet to the venous side, the iATVA system is able to generate up to approximately 5 mm Hg venous recovery while supplying the entire caval flow. CONCLUSIONS: Our experiments show that a totally implantable iATVA system is feasible, which will eliminate the need for external power for Fontan mechanical venous assist and combat gradual postoperative venous remodeling and Fontan failure. Mosby 2018-07 /pmc/articles/PMC6021195/ /pubmed/29666009 http://dx.doi.org/10.1016/j.jtcvs.2018.02.088 Text en © 2018 by The American Association for Thoracic Surgery. All rights reserved. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Article Pekkan, Kerem Aka, Ibrahim Basar Tutsak, Ece Ermek, Erhan Balim, Haldun Lazoglu, Ismail Turkoz, Riza In vitro validation of a self-driving aortic-turbine venous-assist device for Fontan patients |
title | In vitro validation of a self-driving aortic-turbine venous-assist device for Fontan patients |
title_full | In vitro validation of a self-driving aortic-turbine venous-assist device for Fontan patients |
title_fullStr | In vitro validation of a self-driving aortic-turbine venous-assist device for Fontan patients |
title_full_unstemmed | In vitro validation of a self-driving aortic-turbine venous-assist device for Fontan patients |
title_short | In vitro validation of a self-driving aortic-turbine venous-assist device for Fontan patients |
title_sort | in vitro validation of a self-driving aortic-turbine venous-assist device for fontan patients |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6021195/ https://www.ncbi.nlm.nih.gov/pubmed/29666009 http://dx.doi.org/10.1016/j.jtcvs.2018.02.088 |
work_keys_str_mv | AT pekkankerem invitrovalidationofaselfdrivingaorticturbinevenousassistdeviceforfontanpatients AT akaibrahimbasar invitrovalidationofaselfdrivingaorticturbinevenousassistdeviceforfontanpatients AT tutsakece invitrovalidationofaselfdrivingaorticturbinevenousassistdeviceforfontanpatients AT ermekerhan invitrovalidationofaselfdrivingaorticturbinevenousassistdeviceforfontanpatients AT balimhaldun invitrovalidationofaselfdrivingaorticturbinevenousassistdeviceforfontanpatients AT lazogluismail invitrovalidationofaselfdrivingaorticturbinevenousassistdeviceforfontanpatients AT turkozriza invitrovalidationofaselfdrivingaorticturbinevenousassistdeviceforfontanpatients |