Cargando…

A New Method of High-Precision Positioning for an Indoor Pseudolite without Using the Known Point Initialization

Due to the great influence of multipath effect, noise, clock and error on pseudorange, the carrier phase double difference equation is widely used in high-precision indoor pseudolite positioning. The initial position is determined mostly by the known point initialization (KPI) method, and then the a...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhao, Yinzhi, Zhang, Peng, Guo, Jiming, Li, Xin, Wang, Jinling, Yang, Fei, Wang, Xinzhe
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6021852/
https://www.ncbi.nlm.nih.gov/pubmed/29925816
http://dx.doi.org/10.3390/s18061977
_version_ 1783335552085393408
author Zhao, Yinzhi
Zhang, Peng
Guo, Jiming
Li, Xin
Wang, Jinling
Yang, Fei
Wang, Xinzhe
author_facet Zhao, Yinzhi
Zhang, Peng
Guo, Jiming
Li, Xin
Wang, Jinling
Yang, Fei
Wang, Xinzhe
author_sort Zhao, Yinzhi
collection PubMed
description Due to the great influence of multipath effect, noise, clock and error on pseudorange, the carrier phase double difference equation is widely used in high-precision indoor pseudolite positioning. The initial position is determined mostly by the known point initialization (KPI) method, and then the ambiguities can be fixed with the LAMBDA method. In this paper, a new method without using the KPI to achieve high-precision indoor pseudolite positioning is proposed. The initial coordinates can be quickly obtained to meet the accuracy requirement of the indoor LAMBDA method. The detailed processes of the method follows: Aiming at the low-cost single-frequency pseudolite system, the static differential pseudolite system (DPL) method is used to obtain the low-accuracy positioning coordinates of the rover station quickly. Then, the ambiguity function method (AFM) is used to search for the coordinates in the corresponding epoch. The real coordinates obtained by AFM can meet the initial accuracy requirement of the LAMBDA method, so that the double difference carrier phase ambiguities can be correctly fixed. Following the above steps, high-precision indoor pseudolite positioning can be realized. Several experiments, including static and dynamic tests, are conducted to verify the feasibility of the new method. According to the results of the experiments, the initial coordinates with the accuracy of decimeter level through the DPL can be obtained. For the AFM part, both a one-meter search scope and two-centimeter or four-centimeter search steps are used to ensure the precision at the centimeter level and high search efficiency. After dealing with the problem of multiple peaks caused by the ambiguity cosine function, the coordinate information of the maximum ambiguity function value (AFV) is taken as the initial value of the LAMBDA, and the ambiguities can be fixed quickly. The new method provides accuracies at the centimeter level for dynamic experiments and at the millimeter level for static ones.
format Online
Article
Text
id pubmed-6021852
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-60218522018-07-02 A New Method of High-Precision Positioning for an Indoor Pseudolite without Using the Known Point Initialization Zhao, Yinzhi Zhang, Peng Guo, Jiming Li, Xin Wang, Jinling Yang, Fei Wang, Xinzhe Sensors (Basel) Article Due to the great influence of multipath effect, noise, clock and error on pseudorange, the carrier phase double difference equation is widely used in high-precision indoor pseudolite positioning. The initial position is determined mostly by the known point initialization (KPI) method, and then the ambiguities can be fixed with the LAMBDA method. In this paper, a new method without using the KPI to achieve high-precision indoor pseudolite positioning is proposed. The initial coordinates can be quickly obtained to meet the accuracy requirement of the indoor LAMBDA method. The detailed processes of the method follows: Aiming at the low-cost single-frequency pseudolite system, the static differential pseudolite system (DPL) method is used to obtain the low-accuracy positioning coordinates of the rover station quickly. Then, the ambiguity function method (AFM) is used to search for the coordinates in the corresponding epoch. The real coordinates obtained by AFM can meet the initial accuracy requirement of the LAMBDA method, so that the double difference carrier phase ambiguities can be correctly fixed. Following the above steps, high-precision indoor pseudolite positioning can be realized. Several experiments, including static and dynamic tests, are conducted to verify the feasibility of the new method. According to the results of the experiments, the initial coordinates with the accuracy of decimeter level through the DPL can be obtained. For the AFM part, both a one-meter search scope and two-centimeter or four-centimeter search steps are used to ensure the precision at the centimeter level and high search efficiency. After dealing with the problem of multiple peaks caused by the ambiguity cosine function, the coordinate information of the maximum ambiguity function value (AFV) is taken as the initial value of the LAMBDA, and the ambiguities can be fixed quickly. The new method provides accuracies at the centimeter level for dynamic experiments and at the millimeter level for static ones. MDPI 2018-06-20 /pmc/articles/PMC6021852/ /pubmed/29925816 http://dx.doi.org/10.3390/s18061977 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhao, Yinzhi
Zhang, Peng
Guo, Jiming
Li, Xin
Wang, Jinling
Yang, Fei
Wang, Xinzhe
A New Method of High-Precision Positioning for an Indoor Pseudolite without Using the Known Point Initialization
title A New Method of High-Precision Positioning for an Indoor Pseudolite without Using the Known Point Initialization
title_full A New Method of High-Precision Positioning for an Indoor Pseudolite without Using the Known Point Initialization
title_fullStr A New Method of High-Precision Positioning for an Indoor Pseudolite without Using the Known Point Initialization
title_full_unstemmed A New Method of High-Precision Positioning for an Indoor Pseudolite without Using the Known Point Initialization
title_short A New Method of High-Precision Positioning for an Indoor Pseudolite without Using the Known Point Initialization
title_sort new method of high-precision positioning for an indoor pseudolite without using the known point initialization
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6021852/
https://www.ncbi.nlm.nih.gov/pubmed/29925816
http://dx.doi.org/10.3390/s18061977
work_keys_str_mv AT zhaoyinzhi anewmethodofhighprecisionpositioningforanindoorpseudolitewithoutusingtheknownpointinitialization
AT zhangpeng anewmethodofhighprecisionpositioningforanindoorpseudolitewithoutusingtheknownpointinitialization
AT guojiming anewmethodofhighprecisionpositioningforanindoorpseudolitewithoutusingtheknownpointinitialization
AT lixin anewmethodofhighprecisionpositioningforanindoorpseudolitewithoutusingtheknownpointinitialization
AT wangjinling anewmethodofhighprecisionpositioningforanindoorpseudolitewithoutusingtheknownpointinitialization
AT yangfei anewmethodofhighprecisionpositioningforanindoorpseudolitewithoutusingtheknownpointinitialization
AT wangxinzhe anewmethodofhighprecisionpositioningforanindoorpseudolitewithoutusingtheknownpointinitialization
AT zhaoyinzhi newmethodofhighprecisionpositioningforanindoorpseudolitewithoutusingtheknownpointinitialization
AT zhangpeng newmethodofhighprecisionpositioningforanindoorpseudolitewithoutusingtheknownpointinitialization
AT guojiming newmethodofhighprecisionpositioningforanindoorpseudolitewithoutusingtheknownpointinitialization
AT lixin newmethodofhighprecisionpositioningforanindoorpseudolitewithoutusingtheknownpointinitialization
AT wangjinling newmethodofhighprecisionpositioningforanindoorpseudolitewithoutusingtheknownpointinitialization
AT yangfei newmethodofhighprecisionpositioningforanindoorpseudolitewithoutusingtheknownpointinitialization
AT wangxinzhe newmethodofhighprecisionpositioningforanindoorpseudolitewithoutusingtheknownpointinitialization