Cargando…

Measurement Uncertainty Calculations for pH Value Obtained by an Ion-Selective Electrode

An assessment of measurement uncertainty is a task, which has to be the final step of every chemical assay. Apart from a commonly applied typical assessment method, Monte Carlo (MC) simulations may be used. The simulations are frequently performed by a computer program, which has to be written, and...

Descripción completa

Detalles Bibliográficos
Autores principales: Wiora, Józef, Wiora, Alicja
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6022053/
https://www.ncbi.nlm.nih.gov/pubmed/29895807
http://dx.doi.org/10.3390/s18061915
_version_ 1783335595748098048
author Wiora, Józef
Wiora, Alicja
author_facet Wiora, Józef
Wiora, Alicja
author_sort Wiora, Józef
collection PubMed
description An assessment of measurement uncertainty is a task, which has to be the final step of every chemical assay. Apart from a commonly applied typical assessment method, Monte Carlo (MC) simulations may be used. The simulations are frequently performed by a computer program, which has to be written, and therefore some programming skills are required. It is also possible to use a commonly known spreadsheet and perform such simulations without writing any code. Commercial programs dedicated for the purpose are also available. In order to show the advantages and disadvantages of the ways of uncertainty evaluation, i.e., the typical method, the MC method implemented in a program and in a spreadsheet, and commercial programs, a case of pH measurement after two-point calibration is considered in this article. The ways differ in the required mathematical transformations, degrees of software usage, the time spent for the uncertainty calculations, and cost of software. Since analysts may have different mathematical and coding skills and practice, it is impossible to point out the best way of uncertainty assessment—all of them are just as good and give comparable assessments.
format Online
Article
Text
id pubmed-6022053
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-60220532018-07-02 Measurement Uncertainty Calculations for pH Value Obtained by an Ion-Selective Electrode Wiora, Józef Wiora, Alicja Sensors (Basel) Technical Note An assessment of measurement uncertainty is a task, which has to be the final step of every chemical assay. Apart from a commonly applied typical assessment method, Monte Carlo (MC) simulations may be used. The simulations are frequently performed by a computer program, which has to be written, and therefore some programming skills are required. It is also possible to use a commonly known spreadsheet and perform such simulations without writing any code. Commercial programs dedicated for the purpose are also available. In order to show the advantages and disadvantages of the ways of uncertainty evaluation, i.e., the typical method, the MC method implemented in a program and in a spreadsheet, and commercial programs, a case of pH measurement after two-point calibration is considered in this article. The ways differ in the required mathematical transformations, degrees of software usage, the time spent for the uncertainty calculations, and cost of software. Since analysts may have different mathematical and coding skills and practice, it is impossible to point out the best way of uncertainty assessment—all of them are just as good and give comparable assessments. MDPI 2018-06-12 /pmc/articles/PMC6022053/ /pubmed/29895807 http://dx.doi.org/10.3390/s18061915 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Technical Note
Wiora, Józef
Wiora, Alicja
Measurement Uncertainty Calculations for pH Value Obtained by an Ion-Selective Electrode
title Measurement Uncertainty Calculations for pH Value Obtained by an Ion-Selective Electrode
title_full Measurement Uncertainty Calculations for pH Value Obtained by an Ion-Selective Electrode
title_fullStr Measurement Uncertainty Calculations for pH Value Obtained by an Ion-Selective Electrode
title_full_unstemmed Measurement Uncertainty Calculations for pH Value Obtained by an Ion-Selective Electrode
title_short Measurement Uncertainty Calculations for pH Value Obtained by an Ion-Selective Electrode
title_sort measurement uncertainty calculations for ph value obtained by an ion-selective electrode
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6022053/
https://www.ncbi.nlm.nih.gov/pubmed/29895807
http://dx.doi.org/10.3390/s18061915
work_keys_str_mv AT wiorajozef measurementuncertaintycalculationsforphvalueobtainedbyanionselectiveelectrode
AT wioraalicja measurementuncertaintycalculationsforphvalueobtainedbyanionselectiveelectrode