Cargando…
Measurement Uncertainty Calculations for pH Value Obtained by an Ion-Selective Electrode
An assessment of measurement uncertainty is a task, which has to be the final step of every chemical assay. Apart from a commonly applied typical assessment method, Monte Carlo (MC) simulations may be used. The simulations are frequently performed by a computer program, which has to be written, and...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6022053/ https://www.ncbi.nlm.nih.gov/pubmed/29895807 http://dx.doi.org/10.3390/s18061915 |
_version_ | 1783335595748098048 |
---|---|
author | Wiora, Józef Wiora, Alicja |
author_facet | Wiora, Józef Wiora, Alicja |
author_sort | Wiora, Józef |
collection | PubMed |
description | An assessment of measurement uncertainty is a task, which has to be the final step of every chemical assay. Apart from a commonly applied typical assessment method, Monte Carlo (MC) simulations may be used. The simulations are frequently performed by a computer program, which has to be written, and therefore some programming skills are required. It is also possible to use a commonly known spreadsheet and perform such simulations without writing any code. Commercial programs dedicated for the purpose are also available. In order to show the advantages and disadvantages of the ways of uncertainty evaluation, i.e., the typical method, the MC method implemented in a program and in a spreadsheet, and commercial programs, a case of pH measurement after two-point calibration is considered in this article. The ways differ in the required mathematical transformations, degrees of software usage, the time spent for the uncertainty calculations, and cost of software. Since analysts may have different mathematical and coding skills and practice, it is impossible to point out the best way of uncertainty assessment—all of them are just as good and give comparable assessments. |
format | Online Article Text |
id | pubmed-6022053 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-60220532018-07-02 Measurement Uncertainty Calculations for pH Value Obtained by an Ion-Selective Electrode Wiora, Józef Wiora, Alicja Sensors (Basel) Technical Note An assessment of measurement uncertainty is a task, which has to be the final step of every chemical assay. Apart from a commonly applied typical assessment method, Monte Carlo (MC) simulations may be used. The simulations are frequently performed by a computer program, which has to be written, and therefore some programming skills are required. It is also possible to use a commonly known spreadsheet and perform such simulations without writing any code. Commercial programs dedicated for the purpose are also available. In order to show the advantages and disadvantages of the ways of uncertainty evaluation, i.e., the typical method, the MC method implemented in a program and in a spreadsheet, and commercial programs, a case of pH measurement after two-point calibration is considered in this article. The ways differ in the required mathematical transformations, degrees of software usage, the time spent for the uncertainty calculations, and cost of software. Since analysts may have different mathematical and coding skills and practice, it is impossible to point out the best way of uncertainty assessment—all of them are just as good and give comparable assessments. MDPI 2018-06-12 /pmc/articles/PMC6022053/ /pubmed/29895807 http://dx.doi.org/10.3390/s18061915 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Technical Note Wiora, Józef Wiora, Alicja Measurement Uncertainty Calculations for pH Value Obtained by an Ion-Selective Electrode |
title | Measurement Uncertainty Calculations for pH Value Obtained by an Ion-Selective Electrode |
title_full | Measurement Uncertainty Calculations for pH Value Obtained by an Ion-Selective Electrode |
title_fullStr | Measurement Uncertainty Calculations for pH Value Obtained by an Ion-Selective Electrode |
title_full_unstemmed | Measurement Uncertainty Calculations for pH Value Obtained by an Ion-Selective Electrode |
title_short | Measurement Uncertainty Calculations for pH Value Obtained by an Ion-Selective Electrode |
title_sort | measurement uncertainty calculations for ph value obtained by an ion-selective electrode |
topic | Technical Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6022053/ https://www.ncbi.nlm.nih.gov/pubmed/29895807 http://dx.doi.org/10.3390/s18061915 |
work_keys_str_mv | AT wiorajozef measurementuncertaintycalculationsforphvalueobtainedbyanionselectiveelectrode AT wioraalicja measurementuncertaintycalculationsforphvalueobtainedbyanionselectiveelectrode |