Cargando…

Directional Sensitivity of a MEMS-Based Fiber-Optic Extrinsic Fabry–Perot Ultrasonic Sensor for Partial Discharge Detection

Extrinsic Fabry–Perot (FP) interferometric sensors are being intensively applied for partial discharge (PD) detection and localization. Previous research work has mainly focused on novel structures and materials to improve the sensitivity and linear response of these sensors. However, the directiona...

Descripción completa

Detalles Bibliográficos
Autores principales: Si, Wenrong, Fu, Chenzhao, Li, Delin, Li, Haoyong, Yuan, Peng, Yu, Yiting
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6022144/
https://www.ncbi.nlm.nih.gov/pubmed/29925782
http://dx.doi.org/10.3390/s18061975
_version_ 1783335616292847616
author Si, Wenrong
Fu, Chenzhao
Li, Delin
Li, Haoyong
Yuan, Peng
Yu, Yiting
author_facet Si, Wenrong
Fu, Chenzhao
Li, Delin
Li, Haoyong
Yuan, Peng
Yu, Yiting
author_sort Si, Wenrong
collection PubMed
description Extrinsic Fabry–Perot (FP) interferometric sensors are being intensively applied for partial discharge (PD) detection and localization. Previous research work has mainly focused on novel structures and materials to improve the sensitivity and linear response of these sensors. However, the directional response behavior of an FP ultrasonic sensor is also of particular importance in localizing the PD source, which is rarely considered. Here, the directional sensitivity of a microelectromechanical system (MEMS)-based FP ultrasonic sensor with a 5-μm-thick micromechanical vibrating diaphragm is experimentally investigated. Ultrasonic signals from a discharge source with varying incident angles and linear distances are measured and analyzed. The results show that the sensor has a 5.90 dB amplitude fluctuation over a ±60° incident range and an exciting capability to detect weak PD signals from 3 m away due to its high signal–noise ratio. The findings are expected to optimize the configuration of a sensor array and accurately localize the PD source.
format Online
Article
Text
id pubmed-6022144
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-60221442018-07-02 Directional Sensitivity of a MEMS-Based Fiber-Optic Extrinsic Fabry–Perot Ultrasonic Sensor for Partial Discharge Detection Si, Wenrong Fu, Chenzhao Li, Delin Li, Haoyong Yuan, Peng Yu, Yiting Sensors (Basel) Article Extrinsic Fabry–Perot (FP) interferometric sensors are being intensively applied for partial discharge (PD) detection and localization. Previous research work has mainly focused on novel structures and materials to improve the sensitivity and linear response of these sensors. However, the directional response behavior of an FP ultrasonic sensor is also of particular importance in localizing the PD source, which is rarely considered. Here, the directional sensitivity of a microelectromechanical system (MEMS)-based FP ultrasonic sensor with a 5-μm-thick micromechanical vibrating diaphragm is experimentally investigated. Ultrasonic signals from a discharge source with varying incident angles and linear distances are measured and analyzed. The results show that the sensor has a 5.90 dB amplitude fluctuation over a ±60° incident range and an exciting capability to detect weak PD signals from 3 m away due to its high signal–noise ratio. The findings are expected to optimize the configuration of a sensor array and accurately localize the PD source. MDPI 2018-06-20 /pmc/articles/PMC6022144/ /pubmed/29925782 http://dx.doi.org/10.3390/s18061975 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Si, Wenrong
Fu, Chenzhao
Li, Delin
Li, Haoyong
Yuan, Peng
Yu, Yiting
Directional Sensitivity of a MEMS-Based Fiber-Optic Extrinsic Fabry–Perot Ultrasonic Sensor for Partial Discharge Detection
title Directional Sensitivity of a MEMS-Based Fiber-Optic Extrinsic Fabry–Perot Ultrasonic Sensor for Partial Discharge Detection
title_full Directional Sensitivity of a MEMS-Based Fiber-Optic Extrinsic Fabry–Perot Ultrasonic Sensor for Partial Discharge Detection
title_fullStr Directional Sensitivity of a MEMS-Based Fiber-Optic Extrinsic Fabry–Perot Ultrasonic Sensor for Partial Discharge Detection
title_full_unstemmed Directional Sensitivity of a MEMS-Based Fiber-Optic Extrinsic Fabry–Perot Ultrasonic Sensor for Partial Discharge Detection
title_short Directional Sensitivity of a MEMS-Based Fiber-Optic Extrinsic Fabry–Perot Ultrasonic Sensor for Partial Discharge Detection
title_sort directional sensitivity of a mems-based fiber-optic extrinsic fabry–perot ultrasonic sensor for partial discharge detection
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6022144/
https://www.ncbi.nlm.nih.gov/pubmed/29925782
http://dx.doi.org/10.3390/s18061975
work_keys_str_mv AT siwenrong directionalsensitivityofamemsbasedfiberopticextrinsicfabryperotultrasonicsensorforpartialdischargedetection
AT fuchenzhao directionalsensitivityofamemsbasedfiberopticextrinsicfabryperotultrasonicsensorforpartialdischargedetection
AT lidelin directionalsensitivityofamemsbasedfiberopticextrinsicfabryperotultrasonicsensorforpartialdischargedetection
AT lihaoyong directionalsensitivityofamemsbasedfiberopticextrinsicfabryperotultrasonicsensorforpartialdischargedetection
AT yuanpeng directionalsensitivityofamemsbasedfiberopticextrinsicfabryperotultrasonicsensorforpartialdischargedetection
AT yuyiting directionalsensitivityofamemsbasedfiberopticextrinsicfabryperotultrasonicsensorforpartialdischargedetection