Importance of standardizing timing of hematocrit measurement when using cardiovascular magnetic resonance to calculate myocardial extracellular volume (ECV) based on pre- and post-contrast T1 mapping

BACKGROUND: Cardiovascular magnetic resonance (CMR) can be used to calculate myocardial extracellular volume fraction (ECV) by relating the longitudinal relaxation rate in blood and myocardium before and after contrast-injection to hematocrit (Hct) in blood. Hematocrit is known to vary with body pos...

Descripción completa

Detalles Bibliográficos
Autores principales: Engblom, Henrik, Kanski, Mikael, Kopic, Sascha, Nordlund, David, Xanthis, Christos G., Jablonowski, Robert, Heiberg, Einar, Aletras, Anthony H., Carlsson, Marcus, Arheden, Håkan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6022290/
https://www.ncbi.nlm.nih.gov/pubmed/29950178
http://dx.doi.org/10.1186/s12968-018-0464-9
_version_ 1783335647796264960
author Engblom, Henrik
Kanski, Mikael
Kopic, Sascha
Nordlund, David
Xanthis, Christos G.
Jablonowski, Robert
Heiberg, Einar
Aletras, Anthony H.
Carlsson, Marcus
Arheden, Håkan
author_facet Engblom, Henrik
Kanski, Mikael
Kopic, Sascha
Nordlund, David
Xanthis, Christos G.
Jablonowski, Robert
Heiberg, Einar
Aletras, Anthony H.
Carlsson, Marcus
Arheden, Håkan
author_sort Engblom, Henrik
collection PubMed
description BACKGROUND: Cardiovascular magnetic resonance (CMR) can be used to calculate myocardial extracellular volume fraction (ECV) by relating the longitudinal relaxation rate in blood and myocardium before and after contrast-injection to hematocrit (Hct) in blood. Hematocrit is known to vary with body posture, which could affect the calculations of ECV. The aim of this study was to test the hypothesis that there is a significant increase in calculated ECV values if the Hct is sampled after the CMR examination in supine position compared to when the patient arrives at the MR department. METHODS: Forty-three consecutive patients including various pathologies as well as normal findings were included in the study. Venous blood samples were drawn upon arrival to the MR department and directly after the examination with the patient remaining in supine position. A Modified Look-Locker Inversion recovery (MOLLI) protocol was used to acquire mid-ventricular short-axis images before and after contrast injection from which motion-corrected T1 maps were derived and ECV was calculated. RESULTS: Hematocrit decreased from 44.0 ± 3.7% before to 40.6 ± 4.0% after the CMR examination (p < 0.001). This resulted in a change in calculated ECV from 24.7 ± 3.8% before to 26.2 ± 4.2% after the CMR examination (p < 0.001). All patients decreased in Hct after the CMR examination compared to before except for two patients whose Hct remained the same. CONCLUSION: Variability in CMR-derived myocardial ECV can be reduced by standardizing the timing of Hct measurement relative to the CMR examination. Thus, a standardized acquisition of blood sample for Hct after the CMR examination, when the patient is still in supine position, would increase the precision of ECV measurements.
format Online
Article
Text
id pubmed-6022290
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-60222902018-07-09 Importance of standardizing timing of hematocrit measurement when using cardiovascular magnetic resonance to calculate myocardial extracellular volume (ECV) based on pre- and post-contrast T1 mapping Engblom, Henrik Kanski, Mikael Kopic, Sascha Nordlund, David Xanthis, Christos G. Jablonowski, Robert Heiberg, Einar Aletras, Anthony H. Carlsson, Marcus Arheden, Håkan J Cardiovasc Magn Reson Research BACKGROUND: Cardiovascular magnetic resonance (CMR) can be used to calculate myocardial extracellular volume fraction (ECV) by relating the longitudinal relaxation rate in blood and myocardium before and after contrast-injection to hematocrit (Hct) in blood. Hematocrit is known to vary with body posture, which could affect the calculations of ECV. The aim of this study was to test the hypothesis that there is a significant increase in calculated ECV values if the Hct is sampled after the CMR examination in supine position compared to when the patient arrives at the MR department. METHODS: Forty-three consecutive patients including various pathologies as well as normal findings were included in the study. Venous blood samples were drawn upon arrival to the MR department and directly after the examination with the patient remaining in supine position. A Modified Look-Locker Inversion recovery (MOLLI) protocol was used to acquire mid-ventricular short-axis images before and after contrast injection from which motion-corrected T1 maps were derived and ECV was calculated. RESULTS: Hematocrit decreased from 44.0 ± 3.7% before to 40.6 ± 4.0% after the CMR examination (p < 0.001). This resulted in a change in calculated ECV from 24.7 ± 3.8% before to 26.2 ± 4.2% after the CMR examination (p < 0.001). All patients decreased in Hct after the CMR examination compared to before except for two patients whose Hct remained the same. CONCLUSION: Variability in CMR-derived myocardial ECV can be reduced by standardizing the timing of Hct measurement relative to the CMR examination. Thus, a standardized acquisition of blood sample for Hct after the CMR examination, when the patient is still in supine position, would increase the precision of ECV measurements. BioMed Central 2018-06-28 /pmc/articles/PMC6022290/ /pubmed/29950178 http://dx.doi.org/10.1186/s12968-018-0464-9 Text en © The Author(s). 2018 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Engblom, Henrik
Kanski, Mikael
Kopic, Sascha
Nordlund, David
Xanthis, Christos G.
Jablonowski, Robert
Heiberg, Einar
Aletras, Anthony H.
Carlsson, Marcus
Arheden, Håkan
Importance of standardizing timing of hematocrit measurement when using cardiovascular magnetic resonance to calculate myocardial extracellular volume (ECV) based on pre- and post-contrast T1 mapping
title Importance of standardizing timing of hematocrit measurement when using cardiovascular magnetic resonance to calculate myocardial extracellular volume (ECV) based on pre- and post-contrast T1 mapping
title_full Importance of standardizing timing of hematocrit measurement when using cardiovascular magnetic resonance to calculate myocardial extracellular volume (ECV) based on pre- and post-contrast T1 mapping
title_fullStr Importance of standardizing timing of hematocrit measurement when using cardiovascular magnetic resonance to calculate myocardial extracellular volume (ECV) based on pre- and post-contrast T1 mapping
title_full_unstemmed Importance of standardizing timing of hematocrit measurement when using cardiovascular magnetic resonance to calculate myocardial extracellular volume (ECV) based on pre- and post-contrast T1 mapping
title_short Importance of standardizing timing of hematocrit measurement when using cardiovascular magnetic resonance to calculate myocardial extracellular volume (ECV) based on pre- and post-contrast T1 mapping
title_sort importance of standardizing timing of hematocrit measurement when using cardiovascular magnetic resonance to calculate myocardial extracellular volume (ecv) based on pre- and post-contrast t1 mapping
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6022290/
https://www.ncbi.nlm.nih.gov/pubmed/29950178
http://dx.doi.org/10.1186/s12968-018-0464-9
work_keys_str_mv AT engblomhenrik importanceofstandardizingtimingofhematocritmeasurementwhenusingcardiovascularmagneticresonancetocalculatemyocardialextracellularvolumeecvbasedonpreandpostcontrastt1mapping
AT kanskimikael importanceofstandardizingtimingofhematocritmeasurementwhenusingcardiovascularmagneticresonancetocalculatemyocardialextracellularvolumeecvbasedonpreandpostcontrastt1mapping
AT kopicsascha importanceofstandardizingtimingofhematocritmeasurementwhenusingcardiovascularmagneticresonancetocalculatemyocardialextracellularvolumeecvbasedonpreandpostcontrastt1mapping
AT nordlunddavid importanceofstandardizingtimingofhematocritmeasurementwhenusingcardiovascularmagneticresonancetocalculatemyocardialextracellularvolumeecvbasedonpreandpostcontrastt1mapping
AT xanthischristosg importanceofstandardizingtimingofhematocritmeasurementwhenusingcardiovascularmagneticresonancetocalculatemyocardialextracellularvolumeecvbasedonpreandpostcontrastt1mapping
AT jablonowskirobert importanceofstandardizingtimingofhematocritmeasurementwhenusingcardiovascularmagneticresonancetocalculatemyocardialextracellularvolumeecvbasedonpreandpostcontrastt1mapping
AT heibergeinar importanceofstandardizingtimingofhematocritmeasurementwhenusingcardiovascularmagneticresonancetocalculatemyocardialextracellularvolumeecvbasedonpreandpostcontrastt1mapping
AT aletrasanthonyh importanceofstandardizingtimingofhematocritmeasurementwhenusingcardiovascularmagneticresonancetocalculatemyocardialextracellularvolumeecvbasedonpreandpostcontrastt1mapping
AT carlssonmarcus importanceofstandardizingtimingofhematocritmeasurementwhenusingcardiovascularmagneticresonancetocalculatemyocardialextracellularvolumeecvbasedonpreandpostcontrastt1mapping
AT arhedenhakan importanceofstandardizingtimingofhematocritmeasurementwhenusingcardiovascularmagneticresonancetocalculatemyocardialextracellularvolumeecvbasedonpreandpostcontrastt1mapping