Cargando…

Development and Evaluation of a Loop-Mediated Isothermal Amplification Assay for Diagnosis of Schistosoma mansoni Infection in Faecal Samples

Human intestinal schistosomiasis is caused by the blood fluke, Schistosoma mansoni. With intensified efforts to control schistosomiasis by mass drug administration using praziquantel (PZQ), there is an urgent need to have accessible, quality-assured diagnostic tests for case detection and disease su...

Descripción completa

Detalles Bibliográficos
Autores principales: Mwangi, Ibrahim N., Agola, Eric L., Mugambi, Robert M., Shiraho, Esther A., Mkoji, Gerald M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6022337/
https://www.ncbi.nlm.nih.gov/pubmed/30013798
http://dx.doi.org/10.1155/2018/1267826
_version_ 1783335658287267840
author Mwangi, Ibrahim N.
Agola, Eric L.
Mugambi, Robert M.
Shiraho, Esther A.
Mkoji, Gerald M.
author_facet Mwangi, Ibrahim N.
Agola, Eric L.
Mugambi, Robert M.
Shiraho, Esther A.
Mkoji, Gerald M.
author_sort Mwangi, Ibrahim N.
collection PubMed
description Human intestinal schistosomiasis is caused by the blood fluke, Schistosoma mansoni. With intensified efforts to control schistosomiasis by mass drug administration using praziquantel (PZQ), there is an urgent need to have accessible, quality-assured diagnostic tests for case detection and disease surveillance and for monitoring efficacy of treatment and other interventions. Current diagnostic tools are limited by suboptimal sensitivity, slow turn-around-time, affordability, and inability to distinguish current from past infections. We describe a simple and rapid diagnostic assay, based on the loop-mediated isothermal amplification (LAMP) technology for diagnosis of S. mansoni infection in human faecal samples. The LAMP primers used in this assay were previously described and they target a 121-bp DNA repeat sequence in S. mansoni. The LAMP assay was optimized at an isothermal temperature of 63°C for 1 hour. The amplified DNA was either visualized under ultraviolet light after electrophoresis or by directly observing the color change after staining the amplicons with CYBR Green dye. The LAMP assay was evaluated against the microscopy-based procedure and the results were analysed using Cohen's kappa coefficient to determine the degree of agreement between the two techniques. The LAMP assay reliably detected S. mansoni ova DNA in faecal samples and parasite DNA in amounts as low as 32fg. When the assay was tested for specificity against other faecal-based soil-transmitted helminths (STH), no cross-reactivity was observed. The LAMP assay was superior to the Kato-Katz assay with a 97% specificity; a high positivity score reliably detecting S. mansoni and a Kappa Coefficient of 0.9 suggested an exceptional agreement between the two techniques. The LAMP assay developed has great potential for application in field settings to support S. mansoni control and elimination campaigns.
format Online
Article
Text
id pubmed-6022337
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-60223372018-07-16 Development and Evaluation of a Loop-Mediated Isothermal Amplification Assay for Diagnosis of Schistosoma mansoni Infection in Faecal Samples Mwangi, Ibrahim N. Agola, Eric L. Mugambi, Robert M. Shiraho, Esther A. Mkoji, Gerald M. J Parasitol Res Research Article Human intestinal schistosomiasis is caused by the blood fluke, Schistosoma mansoni. With intensified efforts to control schistosomiasis by mass drug administration using praziquantel (PZQ), there is an urgent need to have accessible, quality-assured diagnostic tests for case detection and disease surveillance and for monitoring efficacy of treatment and other interventions. Current diagnostic tools are limited by suboptimal sensitivity, slow turn-around-time, affordability, and inability to distinguish current from past infections. We describe a simple and rapid diagnostic assay, based on the loop-mediated isothermal amplification (LAMP) technology for diagnosis of S. mansoni infection in human faecal samples. The LAMP primers used in this assay were previously described and they target a 121-bp DNA repeat sequence in S. mansoni. The LAMP assay was optimized at an isothermal temperature of 63°C for 1 hour. The amplified DNA was either visualized under ultraviolet light after electrophoresis or by directly observing the color change after staining the amplicons with CYBR Green dye. The LAMP assay was evaluated against the microscopy-based procedure and the results were analysed using Cohen's kappa coefficient to determine the degree of agreement between the two techniques. The LAMP assay reliably detected S. mansoni ova DNA in faecal samples and parasite DNA in amounts as low as 32fg. When the assay was tested for specificity against other faecal-based soil-transmitted helminths (STH), no cross-reactivity was observed. The LAMP assay was superior to the Kato-Katz assay with a 97% specificity; a high positivity score reliably detecting S. mansoni and a Kappa Coefficient of 0.9 suggested an exceptional agreement between the two techniques. The LAMP assay developed has great potential for application in field settings to support S. mansoni control and elimination campaigns. Hindawi 2018-06-14 /pmc/articles/PMC6022337/ /pubmed/30013798 http://dx.doi.org/10.1155/2018/1267826 Text en Copyright © 2018 Ibrahim N. Mwangi et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Mwangi, Ibrahim N.
Agola, Eric L.
Mugambi, Robert M.
Shiraho, Esther A.
Mkoji, Gerald M.
Development and Evaluation of a Loop-Mediated Isothermal Amplification Assay for Diagnosis of Schistosoma mansoni Infection in Faecal Samples
title Development and Evaluation of a Loop-Mediated Isothermal Amplification Assay for Diagnosis of Schistosoma mansoni Infection in Faecal Samples
title_full Development and Evaluation of a Loop-Mediated Isothermal Amplification Assay for Diagnosis of Schistosoma mansoni Infection in Faecal Samples
title_fullStr Development and Evaluation of a Loop-Mediated Isothermal Amplification Assay for Diagnosis of Schistosoma mansoni Infection in Faecal Samples
title_full_unstemmed Development and Evaluation of a Loop-Mediated Isothermal Amplification Assay for Diagnosis of Schistosoma mansoni Infection in Faecal Samples
title_short Development and Evaluation of a Loop-Mediated Isothermal Amplification Assay for Diagnosis of Schistosoma mansoni Infection in Faecal Samples
title_sort development and evaluation of a loop-mediated isothermal amplification assay for diagnosis of schistosoma mansoni infection in faecal samples
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6022337/
https://www.ncbi.nlm.nih.gov/pubmed/30013798
http://dx.doi.org/10.1155/2018/1267826
work_keys_str_mv AT mwangiibrahimn developmentandevaluationofaloopmediatedisothermalamplificationassayfordiagnosisofschistosomamansoniinfectioninfaecalsamples
AT agolaericl developmentandevaluationofaloopmediatedisothermalamplificationassayfordiagnosisofschistosomamansoniinfectioninfaecalsamples
AT mugambirobertm developmentandevaluationofaloopmediatedisothermalamplificationassayfordiagnosisofschistosomamansoniinfectioninfaecalsamples
AT shirahoesthera developmentandevaluationofaloopmediatedisothermalamplificationassayfordiagnosisofschistosomamansoniinfectioninfaecalsamples
AT mkojigeraldm developmentandevaluationofaloopmediatedisothermalamplificationassayfordiagnosisofschistosomamansoniinfectioninfaecalsamples