Cargando…

Evaluation of real-time reverse-transcription loop-mediated isothermal amplification assay for clinical diagnosis of West Nile virus in patients

BACKGROUND & OBJECTIVES: West Nile virus (WNV) is a mosquito-borne flavivirus. The disease can be diagnosed by isolation followed by fluorescent antibody tests, enzyme-linked immunosorbent assay and polymerase chain reaction (PCR) assay. These diagnostic methods are laborious and time-consuming....

Descripción completa

Detalles Bibliográficos
Autores principales: Kumar, Jyoti S., Saxena, Divyasha, Parida, Manmohan, Rathinam, Sivakumar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6022379/
https://www.ncbi.nlm.nih.gov/pubmed/29923519
http://dx.doi.org/10.4103/0971-5916.234607
_version_ 1783335665489936384
author Kumar, Jyoti S.
Saxena, Divyasha
Parida, Manmohan
Rathinam, Sivakumar
author_facet Kumar, Jyoti S.
Saxena, Divyasha
Parida, Manmohan
Rathinam, Sivakumar
author_sort Kumar, Jyoti S.
collection PubMed
description BACKGROUND & OBJECTIVES: West Nile virus (WNV) is a mosquito-borne flavivirus. The disease can be diagnosed by isolation followed by fluorescent antibody tests, enzyme-linked immunosorbent assay and polymerase chain reaction (PCR) assay. These diagnostic methods are laborious and time-consuming. The present study was aimed to evaluate the real-time reverse-transcription loop-mediated isothermal amplification (RT-LAMP) method for rapid, early and accurate diagnosis of WNV. METHODS: A one-step single tube accelerated quantitative RT-LAMP assay was evaluated by targeting the Env gene of WNV. The gene amplification was accomplished by incubating the reaction mixture at 63°C for 60 min in both real time turbidimeter as well as routine laboratory water bath/dry heating bath. To rule out contamination issues, proper negative controls, including no template, no primer; and no enzyme, were always kept alongside each run. The RT-LAMP assay was evaluated on 105 clinical samples from individuals having ocular infection. RESULTS: Of the 105 samples tested, 27 were positive for WNV by RT-LAMP assay. The comparative evaluation with conventional RT-PCR revealed 100 per cent accordance with sensitivity and specificity of 100 and 95 per cent, respectively. The specificity of this assay was confirmed with serum samples obtained from patients with dengue and chikungunya. INTERPRETATION & CONCLUSIONS: The RT-LAMP test seemed to be a sensitive and specific method for rapid detection of WNV infection and would be useful for rapid screening of a large number of clinical samples in endemic areas during outbreaks.
format Online
Article
Text
id pubmed-6022379
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-60223792018-07-13 Evaluation of real-time reverse-transcription loop-mediated isothermal amplification assay for clinical diagnosis of West Nile virus in patients Kumar, Jyoti S. Saxena, Divyasha Parida, Manmohan Rathinam, Sivakumar Indian J Med Res Original Article BACKGROUND & OBJECTIVES: West Nile virus (WNV) is a mosquito-borne flavivirus. The disease can be diagnosed by isolation followed by fluorescent antibody tests, enzyme-linked immunosorbent assay and polymerase chain reaction (PCR) assay. These diagnostic methods are laborious and time-consuming. The present study was aimed to evaluate the real-time reverse-transcription loop-mediated isothermal amplification (RT-LAMP) method for rapid, early and accurate diagnosis of WNV. METHODS: A one-step single tube accelerated quantitative RT-LAMP assay was evaluated by targeting the Env gene of WNV. The gene amplification was accomplished by incubating the reaction mixture at 63°C for 60 min in both real time turbidimeter as well as routine laboratory water bath/dry heating bath. To rule out contamination issues, proper negative controls, including no template, no primer; and no enzyme, were always kept alongside each run. The RT-LAMP assay was evaluated on 105 clinical samples from individuals having ocular infection. RESULTS: Of the 105 samples tested, 27 were positive for WNV by RT-LAMP assay. The comparative evaluation with conventional RT-PCR revealed 100 per cent accordance with sensitivity and specificity of 100 and 95 per cent, respectively. The specificity of this assay was confirmed with serum samples obtained from patients with dengue and chikungunya. INTERPRETATION & CONCLUSIONS: The RT-LAMP test seemed to be a sensitive and specific method for rapid detection of WNV infection and would be useful for rapid screening of a large number of clinical samples in endemic areas during outbreaks. Medknow Publications & Media Pvt Ltd 2018-03 /pmc/articles/PMC6022379/ /pubmed/29923519 http://dx.doi.org/10.4103/0971-5916.234607 Text en Copyright: © 2018 Indian Journal of Medical Research http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Kumar, Jyoti S.
Saxena, Divyasha
Parida, Manmohan
Rathinam, Sivakumar
Evaluation of real-time reverse-transcription loop-mediated isothermal amplification assay for clinical diagnosis of West Nile virus in patients
title Evaluation of real-time reverse-transcription loop-mediated isothermal amplification assay for clinical diagnosis of West Nile virus in patients
title_full Evaluation of real-time reverse-transcription loop-mediated isothermal amplification assay for clinical diagnosis of West Nile virus in patients
title_fullStr Evaluation of real-time reverse-transcription loop-mediated isothermal amplification assay for clinical diagnosis of West Nile virus in patients
title_full_unstemmed Evaluation of real-time reverse-transcription loop-mediated isothermal amplification assay for clinical diagnosis of West Nile virus in patients
title_short Evaluation of real-time reverse-transcription loop-mediated isothermal amplification assay for clinical diagnosis of West Nile virus in patients
title_sort evaluation of real-time reverse-transcription loop-mediated isothermal amplification assay for clinical diagnosis of west nile virus in patients
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6022379/
https://www.ncbi.nlm.nih.gov/pubmed/29923519
http://dx.doi.org/10.4103/0971-5916.234607
work_keys_str_mv AT kumarjyotis evaluationofrealtimereversetranscriptionloopmediatedisothermalamplificationassayforclinicaldiagnosisofwestnilevirusinpatients
AT saxenadivyasha evaluationofrealtimereversetranscriptionloopmediatedisothermalamplificationassayforclinicaldiagnosisofwestnilevirusinpatients
AT paridamanmohan evaluationofrealtimereversetranscriptionloopmediatedisothermalamplificationassayforclinicaldiagnosisofwestnilevirusinpatients
AT rathinamsivakumar evaluationofrealtimereversetranscriptionloopmediatedisothermalamplificationassayforclinicaldiagnosisofwestnilevirusinpatients