Cargando…
Evaluation of the diabetes in pregnancy study group of India criteria and Carpenter-Coustan criteria in the diagnosis of gestational diabetes mellitus
OBJECTIVE: Gestational diabetes mellitus (GDM) is defined as any degree of glucose intolerance that is diagnosed for the first time during pregnancy. This prospective study was undertaken to validate the single-step non-fasting 75 gm Diabetes in Pregnancy Study Group of India (DIPSI) criteria of GDM...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Galenos Publishing
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6022420/ https://www.ncbi.nlm.nih.gov/pubmed/29971182 http://dx.doi.org/10.4274/tjod.57255 |
_version_ | 1783335672462966784 |
---|---|
author | Khan, Shazia Bal, Himadri Khan, Inam Danish Paul, Debashish |
author_facet | Khan, Shazia Bal, Himadri Khan, Inam Danish Paul, Debashish |
author_sort | Khan, Shazia |
collection | PubMed |
description | OBJECTIVE: Gestational diabetes mellitus (GDM) is defined as any degree of glucose intolerance that is diagnosed for the first time during pregnancy. This prospective study was undertaken to validate the single-step non-fasting 75 gm Diabetes in Pregnancy Study Group of India (DIPSI) criteria of GDM in Indian patients in comparison with the two-step fasting 100 gm glucose challenge through the Carpenter Coustan criteria (CCC). MATERIALS AND METHODS: Two hundred patients underwent comparative testing using the DIPSI criteria and CCC. Plasma venous blood glucose levels were estimated using the hexokinase method; values ≥140 mg/dL at 2 hours were considered positive according to the DIPSI criteria. Any two values from ≥95 mg/dL for fasting, ≥180 mg/dL at 1 hour, ≥155 mg/dL at 2 hours, and ≥140 mg/dL at 3 hours were considered positive with the CCC. RESULTS: The mean age and body mass index were 24.26±3.75 years and 20.7±3.07 kg/m2. The sensitivity, specificity, and positive and negative predictive values of the DIPSI guidelines were found as 100%, 97.14%, 83.87%, and 100%, respectively. The positive and negative likelihood ratios were 35.8 and zero. Diagnostic accuracy was found as 97.56%. CONCLUSION: DIPSI having high sensitivity, specificity, negative predictive value and diagnostic accuracy. DIPSI offers simplicity, feasibility, convenience, and repeatability while economizing universal screening and diagnosis of GDM on a mass-scale. The DIPSI procedure has the potential to be applied to the entire obstetric population, in the implementation of public health programs to diagnose GDM in the community, thus reaching the needs of the developing world. |
format | Online Article Text |
id | pubmed-6022420 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Galenos Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-60224202018-07-03 Evaluation of the diabetes in pregnancy study group of India criteria and Carpenter-Coustan criteria in the diagnosis of gestational diabetes mellitus Khan, Shazia Bal, Himadri Khan, Inam Danish Paul, Debashish Turk J Obstet Gynecol Clinical Investigation OBJECTIVE: Gestational diabetes mellitus (GDM) is defined as any degree of glucose intolerance that is diagnosed for the first time during pregnancy. This prospective study was undertaken to validate the single-step non-fasting 75 gm Diabetes in Pregnancy Study Group of India (DIPSI) criteria of GDM in Indian patients in comparison with the two-step fasting 100 gm glucose challenge through the Carpenter Coustan criteria (CCC). MATERIALS AND METHODS: Two hundred patients underwent comparative testing using the DIPSI criteria and CCC. Plasma venous blood glucose levels were estimated using the hexokinase method; values ≥140 mg/dL at 2 hours were considered positive according to the DIPSI criteria. Any two values from ≥95 mg/dL for fasting, ≥180 mg/dL at 1 hour, ≥155 mg/dL at 2 hours, and ≥140 mg/dL at 3 hours were considered positive with the CCC. RESULTS: The mean age and body mass index were 24.26±3.75 years and 20.7±3.07 kg/m2. The sensitivity, specificity, and positive and negative predictive values of the DIPSI guidelines were found as 100%, 97.14%, 83.87%, and 100%, respectively. The positive and negative likelihood ratios were 35.8 and zero. Diagnostic accuracy was found as 97.56%. CONCLUSION: DIPSI having high sensitivity, specificity, negative predictive value and diagnostic accuracy. DIPSI offers simplicity, feasibility, convenience, and repeatability while economizing universal screening and diagnosis of GDM on a mass-scale. The DIPSI procedure has the potential to be applied to the entire obstetric population, in the implementation of public health programs to diagnose GDM in the community, thus reaching the needs of the developing world. Galenos Publishing 2018-06 2018-06-21 /pmc/articles/PMC6022420/ /pubmed/29971182 http://dx.doi.org/10.4274/tjod.57255 Text en ©Copyright 2018 by Turkish Society of Obstetrics and Gynecology Turkish Journal of Obstetrics and Gynecology published by Galenos Publishing House. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Investigation Khan, Shazia Bal, Himadri Khan, Inam Danish Paul, Debashish Evaluation of the diabetes in pregnancy study group of India criteria and Carpenter-Coustan criteria in the diagnosis of gestational diabetes mellitus |
title | Evaluation of the diabetes in pregnancy study group of India criteria and Carpenter-Coustan criteria in the diagnosis of gestational diabetes mellitus |
title_full | Evaluation of the diabetes in pregnancy study group of India criteria and Carpenter-Coustan criteria in the diagnosis of gestational diabetes mellitus |
title_fullStr | Evaluation of the diabetes in pregnancy study group of India criteria and Carpenter-Coustan criteria in the diagnosis of gestational diabetes mellitus |
title_full_unstemmed | Evaluation of the diabetes in pregnancy study group of India criteria and Carpenter-Coustan criteria in the diagnosis of gestational diabetes mellitus |
title_short | Evaluation of the diabetes in pregnancy study group of India criteria and Carpenter-Coustan criteria in the diagnosis of gestational diabetes mellitus |
title_sort | evaluation of the diabetes in pregnancy study group of india criteria and carpenter-coustan criteria in the diagnosis of gestational diabetes mellitus |
topic | Clinical Investigation |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6022420/ https://www.ncbi.nlm.nih.gov/pubmed/29971182 http://dx.doi.org/10.4274/tjod.57255 |
work_keys_str_mv | AT khanshazia evaluationofthediabetesinpregnancystudygroupofindiacriteriaandcarpentercoustancriteriainthediagnosisofgestationaldiabetesmellitus AT balhimadri evaluationofthediabetesinpregnancystudygroupofindiacriteriaandcarpentercoustancriteriainthediagnosisofgestationaldiabetesmellitus AT khaninamdanish evaluationofthediabetesinpregnancystudygroupofindiacriteriaandcarpentercoustancriteriainthediagnosisofgestationaldiabetesmellitus AT pauldebashish evaluationofthediabetesinpregnancystudygroupofindiacriteriaandcarpentercoustancriteriainthediagnosisofgestationaldiabetesmellitus |