Cargando…
New Carrier Made from Glass Nanofibres for the Colorimetric Biosensor of Cholinesterase Inhibitors
Cholinesterase inhibitors are widely used as pesticides in agriculture, but also form a group of organophosphates known as nerve chemical warfare agents. This calls for close attention regarding their detection, including the use of various biosensors. One such biosensor made in the Czech Republic i...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6023030/ https://www.ncbi.nlm.nih.gov/pubmed/29848955 http://dx.doi.org/10.3390/bios8020051 |
_version_ | 1783335779083223040 |
---|---|
author | Matějovský, Lukáš Pitschmann, Vladimír |
author_facet | Matějovský, Lukáš Pitschmann, Vladimír |
author_sort | Matějovský, Lukáš |
collection | PubMed |
description | Cholinesterase inhibitors are widely used as pesticides in agriculture, but also form a group of organophosphates known as nerve chemical warfare agents. This calls for close attention regarding their detection, including the use of various biosensors. One such biosensor made in the Czech Republic is the Detehit, which is based on a cholinesterase reaction that is assessed using a colour indicator—the Ellman’s reagent—which is anchored on cellulose filter paper together with the substrate. With the use of this biosensor, detection is simple, quick, and sensitive. However, its disadvantage is that a less pronounced yellow discoloration occurs, especially under difficult light conditions. As a possible solution, a new indicator/substrate carrier has been designed. It is made of glass nanofibres, so the physical characteristics of the carrier positively influence reaction conditions, and as a result improve the colour response of the biosensor. The authors present and discuss some of the results of the study of this carrier under various experimental conditions. These findings have been used for the development of a modified Detehit biosensor. |
format | Online Article Text |
id | pubmed-6023030 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-60230302018-07-02 New Carrier Made from Glass Nanofibres for the Colorimetric Biosensor of Cholinesterase Inhibitors Matějovský, Lukáš Pitschmann, Vladimír Biosensors (Basel) Article Cholinesterase inhibitors are widely used as pesticides in agriculture, but also form a group of organophosphates known as nerve chemical warfare agents. This calls for close attention regarding their detection, including the use of various biosensors. One such biosensor made in the Czech Republic is the Detehit, which is based on a cholinesterase reaction that is assessed using a colour indicator—the Ellman’s reagent—which is anchored on cellulose filter paper together with the substrate. With the use of this biosensor, detection is simple, quick, and sensitive. However, its disadvantage is that a less pronounced yellow discoloration occurs, especially under difficult light conditions. As a possible solution, a new indicator/substrate carrier has been designed. It is made of glass nanofibres, so the physical characteristics of the carrier positively influence reaction conditions, and as a result improve the colour response of the biosensor. The authors present and discuss some of the results of the study of this carrier under various experimental conditions. These findings have been used for the development of a modified Detehit biosensor. MDPI 2018-05-30 /pmc/articles/PMC6023030/ /pubmed/29848955 http://dx.doi.org/10.3390/bios8020051 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Matějovský, Lukáš Pitschmann, Vladimír New Carrier Made from Glass Nanofibres for the Colorimetric Biosensor of Cholinesterase Inhibitors |
title | New Carrier Made from Glass Nanofibres for the Colorimetric Biosensor of Cholinesterase Inhibitors |
title_full | New Carrier Made from Glass Nanofibres for the Colorimetric Biosensor of Cholinesterase Inhibitors |
title_fullStr | New Carrier Made from Glass Nanofibres for the Colorimetric Biosensor of Cholinesterase Inhibitors |
title_full_unstemmed | New Carrier Made from Glass Nanofibres for the Colorimetric Biosensor of Cholinesterase Inhibitors |
title_short | New Carrier Made from Glass Nanofibres for the Colorimetric Biosensor of Cholinesterase Inhibitors |
title_sort | new carrier made from glass nanofibres for the colorimetric biosensor of cholinesterase inhibitors |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6023030/ https://www.ncbi.nlm.nih.gov/pubmed/29848955 http://dx.doi.org/10.3390/bios8020051 |
work_keys_str_mv | AT matejovskylukas newcarriermadefromglassnanofibresforthecolorimetricbiosensorofcholinesteraseinhibitors AT pitschmannvladimir newcarriermadefromglassnanofibresforthecolorimetricbiosensorofcholinesteraseinhibitors |