Catheter radiofrequency ablation for arrhythmias under the guidance of the Carto 3 three-dimensional mapping system in an operating room without digital subtraction angiography

Several studies have reported the efficacy of a zero-fluoroscopy approach for catheter radiofrequency ablation of arrhythmias in a digital subtraction angiography (DSA) room. However, no reports are available on the ablation of arrhythmias in the absence of DSA in the operating room. To investigate...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Xingfu, Chen, Yanjia, Huang, Zheng, He, Liwei, Liu, Shenrong, Deng, Xiaojiang, Wang, Yongsheng, Li, Rucheng, Xu, Dingli, Peng, Jian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6023703/
https://www.ncbi.nlm.nih.gov/pubmed/29923993
http://dx.doi.org/10.1097/MD.0000000000011044
_version_ 1783335921473552384
author Huang, Xingfu
Chen, Yanjia
Huang, Zheng
He, Liwei
Liu, Shenrong
Deng, Xiaojiang
Wang, Yongsheng
Li, Rucheng
Xu, Dingli
Peng, Jian
author_facet Huang, Xingfu
Chen, Yanjia
Huang, Zheng
He, Liwei
Liu, Shenrong
Deng, Xiaojiang
Wang, Yongsheng
Li, Rucheng
Xu, Dingli
Peng, Jian
author_sort Huang, Xingfu
collection PubMed
description Several studies have reported the efficacy of a zero-fluoroscopy approach for catheter radiofrequency ablation of arrhythmias in a digital subtraction angiography (DSA) room. However, no reports are available on the ablation of arrhythmias in the absence of DSA in the operating room. To investigate the efficacy and safety of catheter radiofrequency ablation for arrhythmias under the guidance of a Carto 3 three-dimensional (3D) mapping system in an operating room without DSA. Patients were enrolled according to the type of arrhythmia. The Carto 3 mapping system was used to reconstruct heart models and guide the electrophysiologic examination, mapping, and ablation. The total procedure, reconstruction, electrophysiologic examination, and mapping times were recorded. Furthermore, immediate success rates and complications were also recorded. A total of 20 patients were enrolled, including 12 males. The average age was 51.3 ± 17.2 (19–76) years. Nine cases of atrioventricular nodal re-entrant tachycardia, 7 cases of frequent ventricular premature contractions, 3 cases of Wolff–Parkinson–White syndrome, and 1 case of typical atrial flutter were included. All arrhythmias were successfully ablated. The procedure time was 127.0 ± 21.0 (99–177) minutes, the reconstruction time was 6.5 ± 2.9 (3–14) minutes, the electrophysiologic study time was 10.4 ± 3.4 (6–20) minutes, and the mapping time was 11.7 ± 8.3 (3–36) minutes. No complications occurred. Radiofrequency ablation of arrhythmias without DSA is effective and feasible under the guidance of the Carto 3 mapping system. However, the electrophysiology physician must have sufficient experience, and related emergency measures must be present to ensure safety.
format Online
Article
Text
id pubmed-6023703
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-60237032018-07-03 Catheter radiofrequency ablation for arrhythmias under the guidance of the Carto 3 three-dimensional mapping system in an operating room without digital subtraction angiography Huang, Xingfu Chen, Yanjia Huang, Zheng He, Liwei Liu, Shenrong Deng, Xiaojiang Wang, Yongsheng Li, Rucheng Xu, Dingli Peng, Jian Medicine (Baltimore) Research Article Several studies have reported the efficacy of a zero-fluoroscopy approach for catheter radiofrequency ablation of arrhythmias in a digital subtraction angiography (DSA) room. However, no reports are available on the ablation of arrhythmias in the absence of DSA in the operating room. To investigate the efficacy and safety of catheter radiofrequency ablation for arrhythmias under the guidance of a Carto 3 three-dimensional (3D) mapping system in an operating room without DSA. Patients were enrolled according to the type of arrhythmia. The Carto 3 mapping system was used to reconstruct heart models and guide the electrophysiologic examination, mapping, and ablation. The total procedure, reconstruction, electrophysiologic examination, and mapping times were recorded. Furthermore, immediate success rates and complications were also recorded. A total of 20 patients were enrolled, including 12 males. The average age was 51.3 ± 17.2 (19–76) years. Nine cases of atrioventricular nodal re-entrant tachycardia, 7 cases of frequent ventricular premature contractions, 3 cases of Wolff–Parkinson–White syndrome, and 1 case of typical atrial flutter were included. All arrhythmias were successfully ablated. The procedure time was 127.0 ± 21.0 (99–177) minutes, the reconstruction time was 6.5 ± 2.9 (3–14) minutes, the electrophysiologic study time was 10.4 ± 3.4 (6–20) minutes, and the mapping time was 11.7 ± 8.3 (3–36) minutes. No complications occurred. Radiofrequency ablation of arrhythmias without DSA is effective and feasible under the guidance of the Carto 3 mapping system. However, the electrophysiology physician must have sufficient experience, and related emergency measures must be present to ensure safety. Wolters Kluwer Health 2018-06-22 /pmc/articles/PMC6023703/ /pubmed/29923993 http://dx.doi.org/10.1097/MD.0000000000011044 Text en Copyright © 2018 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by/4.0 This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0
spellingShingle Research Article
Huang, Xingfu
Chen, Yanjia
Huang, Zheng
He, Liwei
Liu, Shenrong
Deng, Xiaojiang
Wang, Yongsheng
Li, Rucheng
Xu, Dingli
Peng, Jian
Catheter radiofrequency ablation for arrhythmias under the guidance of the Carto 3 three-dimensional mapping system in an operating room without digital subtraction angiography
title Catheter radiofrequency ablation for arrhythmias under the guidance of the Carto 3 three-dimensional mapping system in an operating room without digital subtraction angiography
title_full Catheter radiofrequency ablation for arrhythmias under the guidance of the Carto 3 three-dimensional mapping system in an operating room without digital subtraction angiography
title_fullStr Catheter radiofrequency ablation for arrhythmias under the guidance of the Carto 3 three-dimensional mapping system in an operating room without digital subtraction angiography
title_full_unstemmed Catheter radiofrequency ablation for arrhythmias under the guidance of the Carto 3 three-dimensional mapping system in an operating room without digital subtraction angiography
title_short Catheter radiofrequency ablation for arrhythmias under the guidance of the Carto 3 three-dimensional mapping system in an operating room without digital subtraction angiography
title_sort catheter radiofrequency ablation for arrhythmias under the guidance of the carto 3 three-dimensional mapping system in an operating room without digital subtraction angiography
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6023703/
https://www.ncbi.nlm.nih.gov/pubmed/29923993
http://dx.doi.org/10.1097/MD.0000000000011044
work_keys_str_mv AT huangxingfu catheterradiofrequencyablationforarrhythmiasundertheguidanceofthecarto3threedimensionalmappingsysteminanoperatingroomwithoutdigitalsubtractionangiography
AT chenyanjia catheterradiofrequencyablationforarrhythmiasundertheguidanceofthecarto3threedimensionalmappingsysteminanoperatingroomwithoutdigitalsubtractionangiography
AT huangzheng catheterradiofrequencyablationforarrhythmiasundertheguidanceofthecarto3threedimensionalmappingsysteminanoperatingroomwithoutdigitalsubtractionangiography
AT heliwei catheterradiofrequencyablationforarrhythmiasundertheguidanceofthecarto3threedimensionalmappingsysteminanoperatingroomwithoutdigitalsubtractionangiography
AT liushenrong catheterradiofrequencyablationforarrhythmiasundertheguidanceofthecarto3threedimensionalmappingsysteminanoperatingroomwithoutdigitalsubtractionangiography
AT dengxiaojiang catheterradiofrequencyablationforarrhythmiasundertheguidanceofthecarto3threedimensionalmappingsysteminanoperatingroomwithoutdigitalsubtractionangiography
AT wangyongsheng catheterradiofrequencyablationforarrhythmiasundertheguidanceofthecarto3threedimensionalmappingsysteminanoperatingroomwithoutdigitalsubtractionangiography
AT lirucheng catheterradiofrequencyablationforarrhythmiasundertheguidanceofthecarto3threedimensionalmappingsysteminanoperatingroomwithoutdigitalsubtractionangiography
AT xudingli catheterradiofrequencyablationforarrhythmiasundertheguidanceofthecarto3threedimensionalmappingsysteminanoperatingroomwithoutdigitalsubtractionangiography
AT pengjian catheterradiofrequencyablationforarrhythmiasundertheguidanceofthecarto3threedimensionalmappingsysteminanoperatingroomwithoutdigitalsubtractionangiography