Cargando…

Wearable camera-derived microenvironments in relation to personal exposure to PM(2.5)

Data regarding which microenvironments drive exposure to air pollution in low and middle income countries are scarce. Our objective was to identify sources of time-resolved personal PM(2.5) exposure in peri-urban India using wearable camera-derived microenvironmental information. We conducted a pane...

Descripción completa

Detalles Bibliográficos
Autores principales: Salmon, Maëlle, Milà, Carles, Bhogadi, Santhi, Addanki, Srivalli, Madhira, Pavitra, Muddepaka, Niharika, Mora, Amaravathi, Sanchez, Margaux, Kinra, Sanjay, Sreekanth, V., Doherty, Aiden, Marshall, Julian D., Tonne, Cathryn
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6024072/
https://www.ncbi.nlm.nih.gov/pubmed/29778830
http://dx.doi.org/10.1016/j.envint.2018.05.021
_version_ 1783335988929495040
author Salmon, Maëlle
Milà, Carles
Bhogadi, Santhi
Addanki, Srivalli
Madhira, Pavitra
Muddepaka, Niharika
Mora, Amaravathi
Sanchez, Margaux
Kinra, Sanjay
Sreekanth, V.
Doherty, Aiden
Marshall, Julian D.
Tonne, Cathryn
author_facet Salmon, Maëlle
Milà, Carles
Bhogadi, Santhi
Addanki, Srivalli
Madhira, Pavitra
Muddepaka, Niharika
Mora, Amaravathi
Sanchez, Margaux
Kinra, Sanjay
Sreekanth, V.
Doherty, Aiden
Marshall, Julian D.
Tonne, Cathryn
author_sort Salmon, Maëlle
collection PubMed
description Data regarding which microenvironments drive exposure to air pollution in low and middle income countries are scarce. Our objective was to identify sources of time-resolved personal PM(2.5) exposure in peri-urban India using wearable camera-derived microenvironmental information. We conducted a panel study with up to 6 repeated non-consecutive 24 h measurements on 45 participants (186 participant-days). Camera images were manually annotated to derive visual concepts indicative of microenvironments and activities. Men had slightly higher daily mean PM(2.5) exposure (43 μg/m(3)) compared to women (39 μg/m(3)). Cameras helped identify that men also had higher exposures when near a biomass cooking unit (mean (sd) μg/m(3): 119 (383) for men vs 83 (196) for women) and presence in the kitchen (133 (311) for men vs 48 (94) for women). Visual concepts associated in regression analysis with higher 5-minute PM(2.5) for both sexes included: smoking (+93% (95% confidence interval: 63%, 129%) in men, +29% (95% CI: 2%, 63%) in women), biomass cooking unit (+57% (95% CI: 28%, 93%) in men, +69% (95% CI: 48%, 93%) in women), visible flame or smoke (+90% (95% CI: 48%, 144%) in men, +39% (95% CI: 6%, 83%) in women), and presence in the kitchen (+49% (95% CI: 27%, 75%) in men, +14% (95% CI: 7%, 20%) in women). Our results indicate wearable cameras can provide objective, high time-resolution microenvironmental data useful for identifying peak exposures and providing insights not evident using standard self-reported time-activity.
format Online
Article
Text
id pubmed-6024072
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier Science
record_format MEDLINE/PubMed
spelling pubmed-60240722018-08-01 Wearable camera-derived microenvironments in relation to personal exposure to PM(2.5) Salmon, Maëlle Milà, Carles Bhogadi, Santhi Addanki, Srivalli Madhira, Pavitra Muddepaka, Niharika Mora, Amaravathi Sanchez, Margaux Kinra, Sanjay Sreekanth, V. Doherty, Aiden Marshall, Julian D. Tonne, Cathryn Environ Int Article Data regarding which microenvironments drive exposure to air pollution in low and middle income countries are scarce. Our objective was to identify sources of time-resolved personal PM(2.5) exposure in peri-urban India using wearable camera-derived microenvironmental information. We conducted a panel study with up to 6 repeated non-consecutive 24 h measurements on 45 participants (186 participant-days). Camera images were manually annotated to derive visual concepts indicative of microenvironments and activities. Men had slightly higher daily mean PM(2.5) exposure (43 μg/m(3)) compared to women (39 μg/m(3)). Cameras helped identify that men also had higher exposures when near a biomass cooking unit (mean (sd) μg/m(3): 119 (383) for men vs 83 (196) for women) and presence in the kitchen (133 (311) for men vs 48 (94) for women). Visual concepts associated in regression analysis with higher 5-minute PM(2.5) for both sexes included: smoking (+93% (95% confidence interval: 63%, 129%) in men, +29% (95% CI: 2%, 63%) in women), biomass cooking unit (+57% (95% CI: 28%, 93%) in men, +69% (95% CI: 48%, 93%) in women), visible flame or smoke (+90% (95% CI: 48%, 144%) in men, +39% (95% CI: 6%, 83%) in women), and presence in the kitchen (+49% (95% CI: 27%, 75%) in men, +14% (95% CI: 7%, 20%) in women). Our results indicate wearable cameras can provide objective, high time-resolution microenvironmental data useful for identifying peak exposures and providing insights not evident using standard self-reported time-activity. Elsevier Science 2018-08 /pmc/articles/PMC6024072/ /pubmed/29778830 http://dx.doi.org/10.1016/j.envint.2018.05.021 Text en © 2018 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Salmon, Maëlle
Milà, Carles
Bhogadi, Santhi
Addanki, Srivalli
Madhira, Pavitra
Muddepaka, Niharika
Mora, Amaravathi
Sanchez, Margaux
Kinra, Sanjay
Sreekanth, V.
Doherty, Aiden
Marshall, Julian D.
Tonne, Cathryn
Wearable camera-derived microenvironments in relation to personal exposure to PM(2.5)
title Wearable camera-derived microenvironments in relation to personal exposure to PM(2.5)
title_full Wearable camera-derived microenvironments in relation to personal exposure to PM(2.5)
title_fullStr Wearable camera-derived microenvironments in relation to personal exposure to PM(2.5)
title_full_unstemmed Wearable camera-derived microenvironments in relation to personal exposure to PM(2.5)
title_short Wearable camera-derived microenvironments in relation to personal exposure to PM(2.5)
title_sort wearable camera-derived microenvironments in relation to personal exposure to pm(2.5)
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6024072/
https://www.ncbi.nlm.nih.gov/pubmed/29778830
http://dx.doi.org/10.1016/j.envint.2018.05.021
work_keys_str_mv AT salmonmaelle wearablecameraderivedmicroenvironmentsinrelationtopersonalexposuretopm25
AT milacarles wearablecameraderivedmicroenvironmentsinrelationtopersonalexposuretopm25
AT bhogadisanthi wearablecameraderivedmicroenvironmentsinrelationtopersonalexposuretopm25
AT addankisrivalli wearablecameraderivedmicroenvironmentsinrelationtopersonalexposuretopm25
AT madhirapavitra wearablecameraderivedmicroenvironmentsinrelationtopersonalexposuretopm25
AT muddepakaniharika wearablecameraderivedmicroenvironmentsinrelationtopersonalexposuretopm25
AT moraamaravathi wearablecameraderivedmicroenvironmentsinrelationtopersonalexposuretopm25
AT sanchezmargaux wearablecameraderivedmicroenvironmentsinrelationtopersonalexposuretopm25
AT kinrasanjay wearablecameraderivedmicroenvironmentsinrelationtopersonalexposuretopm25
AT sreekanthv wearablecameraderivedmicroenvironmentsinrelationtopersonalexposuretopm25
AT dohertyaiden wearablecameraderivedmicroenvironmentsinrelationtopersonalexposuretopm25
AT marshalljuliand wearablecameraderivedmicroenvironmentsinrelationtopersonalexposuretopm25
AT tonnecathryn wearablecameraderivedmicroenvironmentsinrelationtopersonalexposuretopm25