Cargando…
Safety of medial dissection of the thyroid gland along the trachea based on anatomic constancy of the laryngeal entry point of the recurrent laryngeal nerve
PURPOSE: The purpose of this study was to determine the extent of safety of medial dissection of the thyroid gland along the trachea. Medial to lateral dissection of the thyroid gland along the trachea after early division of the isthmus has been known to be a useful technique in thyroid surgery, es...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Surgical Society
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6024085/ https://www.ncbi.nlm.nih.gov/pubmed/29963535 http://dx.doi.org/10.4174/astr.2018.95.1.16 |
_version_ | 1783335991479631872 |
---|---|
author | Kang, Kyung Ho Song, Ra-Yeong Suh, Yong Joon Park, Sung Jun |
author_facet | Kang, Kyung Ho Song, Ra-Yeong Suh, Yong Joon Park, Sung Jun |
author_sort | Kang, Kyung Ho |
collection | PubMed |
description | PURPOSE: The purpose of this study was to determine the extent of safety of medial dissection of the thyroid gland along the trachea. Medial to lateral dissection of the thyroid gland along the trachea after early division of the isthmus has been known to be a useful technique in thyroid surgery, especially for difficult cases, but the risk of injury of the recurrent laryngeal nerve (RLN) has constrained thyroid surgeons from utilizing this technique to its full extent. METHODS: Distances of the laryngeal entry point (LEP) of 134 RLNs of 71 patients from the midline of the trachea, and some other anatomical distances, were measured intraoperatively. The relationships of the intraoperatively measured data with circumferences of the cartilaginous portion of the trachea (CCT) around LEP measured preoperatively by CT scan were evaluated. RESULTS: LEP was always located within 2 mm vertically from the horizontally extended line of the inferior border of the cricoid cartilage and was the closest point from the midline in the whole course of the RLN. The distance between LEP and the midline was very closely correlated with CCT measured on preoperative CT scan, and it can be accurately calculated with a regression equation; Distance between LEP and the midline = (0.42 × CCT) + (1.2 × sex) + 3.2 (mm) (sex: female=0, male=1; R(2) = 0.85). CONCLUSION: Early division of the isthmus and dissecting the thyroid off the trachea to the calculated extent is a safe and effective procedure. |
format | Online Article Text |
id | pubmed-6024085 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | The Korean Surgical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-60240852018-07-01 Safety of medial dissection of the thyroid gland along the trachea based on anatomic constancy of the laryngeal entry point of the recurrent laryngeal nerve Kang, Kyung Ho Song, Ra-Yeong Suh, Yong Joon Park, Sung Jun Ann Surg Treat Res Original Article PURPOSE: The purpose of this study was to determine the extent of safety of medial dissection of the thyroid gland along the trachea. Medial to lateral dissection of the thyroid gland along the trachea after early division of the isthmus has been known to be a useful technique in thyroid surgery, especially for difficult cases, but the risk of injury of the recurrent laryngeal nerve (RLN) has constrained thyroid surgeons from utilizing this technique to its full extent. METHODS: Distances of the laryngeal entry point (LEP) of 134 RLNs of 71 patients from the midline of the trachea, and some other anatomical distances, were measured intraoperatively. The relationships of the intraoperatively measured data with circumferences of the cartilaginous portion of the trachea (CCT) around LEP measured preoperatively by CT scan were evaluated. RESULTS: LEP was always located within 2 mm vertically from the horizontally extended line of the inferior border of the cricoid cartilage and was the closest point from the midline in the whole course of the RLN. The distance between LEP and the midline was very closely correlated with CCT measured on preoperative CT scan, and it can be accurately calculated with a regression equation; Distance between LEP and the midline = (0.42 × CCT) + (1.2 × sex) + 3.2 (mm) (sex: female=0, male=1; R(2) = 0.85). CONCLUSION: Early division of the isthmus and dissecting the thyroid off the trachea to the calculated extent is a safe and effective procedure. The Korean Surgical Society 2018-07 2018-06-26 /pmc/articles/PMC6024085/ /pubmed/29963535 http://dx.doi.org/10.4174/astr.2018.95.1.16 Text en Copyright © 2018, the Korean Surgical Society http://creativecommons.org/licenses/by-nc/4.0/ Annals of Surgical Treatment and Research is an Open Access Journal. All articles are distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Kang, Kyung Ho Song, Ra-Yeong Suh, Yong Joon Park, Sung Jun Safety of medial dissection of the thyroid gland along the trachea based on anatomic constancy of the laryngeal entry point of the recurrent laryngeal nerve |
title | Safety of medial dissection of the thyroid gland along the trachea based on anatomic constancy of the laryngeal entry point of the recurrent laryngeal nerve |
title_full | Safety of medial dissection of the thyroid gland along the trachea based on anatomic constancy of the laryngeal entry point of the recurrent laryngeal nerve |
title_fullStr | Safety of medial dissection of the thyroid gland along the trachea based on anatomic constancy of the laryngeal entry point of the recurrent laryngeal nerve |
title_full_unstemmed | Safety of medial dissection of the thyroid gland along the trachea based on anatomic constancy of the laryngeal entry point of the recurrent laryngeal nerve |
title_short | Safety of medial dissection of the thyroid gland along the trachea based on anatomic constancy of the laryngeal entry point of the recurrent laryngeal nerve |
title_sort | safety of medial dissection of the thyroid gland along the trachea based on anatomic constancy of the laryngeal entry point of the recurrent laryngeal nerve |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6024085/ https://www.ncbi.nlm.nih.gov/pubmed/29963535 http://dx.doi.org/10.4174/astr.2018.95.1.16 |
work_keys_str_mv | AT kangkyungho safetyofmedialdissectionofthethyroidglandalongthetracheabasedonanatomicconstancyofthelaryngealentrypointoftherecurrentlaryngealnerve AT songrayeong safetyofmedialdissectionofthethyroidglandalongthetracheabasedonanatomicconstancyofthelaryngealentrypointoftherecurrentlaryngealnerve AT suhyongjoon safetyofmedialdissectionofthethyroidglandalongthetracheabasedonanatomicconstancyofthelaryngealentrypointoftherecurrentlaryngealnerve AT parksungjun safetyofmedialdissectionofthethyroidglandalongthetracheabasedonanatomicconstancyofthelaryngealentrypointoftherecurrentlaryngealnerve |