Cargando…

Effect of Temperature Distribution in Ultrasonically Welded Joints of Copper Wire and Sheet Used for Electrical Contacts

The temperature distribution occurring at the interface while joining a simple electrical contact comprising of a copper wire and a copper sheet using ultrasonic metal welding was analyzed using finite element method. Heat flux due to plastic deformation and friction was calculated and provided as i...

Descripción completa

Detalles Bibliográficos
Autor principal: Pradeep Kumar, Jeyaraj
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6025159/
https://www.ncbi.nlm.nih.gov/pubmed/29904006
http://dx.doi.org/10.3390/ma11061010
_version_ 1783336220424667136
author Pradeep Kumar, Jeyaraj
author_facet Pradeep Kumar, Jeyaraj
author_sort Pradeep Kumar, Jeyaraj
collection PubMed
description The temperature distribution occurring at the interface while joining a simple electrical contact comprising of a copper wire and a copper sheet using ultrasonic metal welding was analyzed using finite element method. Heat flux due to plastic deformation and friction was calculated and provided as input load for simulation of temperature distribution. The results of temperature obtained from simulation are found to be in good agreement with the results of temperature from experiments measured using thermocouple. Special focus was given to how the heat generated at the wire–sheet interface affect the strength of the joint in tension. With the knowledge of heat generated at the interface while welding, it is possible to control the strength of the joint and produce defect free joints. Based on the results from finite element analysis and experiments, it is observed that the influence of heat developed due to friction and plastic deformation of metallic specimens has a significant effect on the progress of welding and strength of the joint.
format Online
Article
Text
id pubmed-6025159
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-60251592018-07-09 Effect of Temperature Distribution in Ultrasonically Welded Joints of Copper Wire and Sheet Used for Electrical Contacts Pradeep Kumar, Jeyaraj Materials (Basel) Article The temperature distribution occurring at the interface while joining a simple electrical contact comprising of a copper wire and a copper sheet using ultrasonic metal welding was analyzed using finite element method. Heat flux due to plastic deformation and friction was calculated and provided as input load for simulation of temperature distribution. The results of temperature obtained from simulation are found to be in good agreement with the results of temperature from experiments measured using thermocouple. Special focus was given to how the heat generated at the wire–sheet interface affect the strength of the joint in tension. With the knowledge of heat generated at the interface while welding, it is possible to control the strength of the joint and produce defect free joints. Based on the results from finite element analysis and experiments, it is observed that the influence of heat developed due to friction and plastic deformation of metallic specimens has a significant effect on the progress of welding and strength of the joint. MDPI 2018-06-14 /pmc/articles/PMC6025159/ /pubmed/29904006 http://dx.doi.org/10.3390/ma11061010 Text en © 2018 by the author. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Pradeep Kumar, Jeyaraj
Effect of Temperature Distribution in Ultrasonically Welded Joints of Copper Wire and Sheet Used for Electrical Contacts
title Effect of Temperature Distribution in Ultrasonically Welded Joints of Copper Wire and Sheet Used for Electrical Contacts
title_full Effect of Temperature Distribution in Ultrasonically Welded Joints of Copper Wire and Sheet Used for Electrical Contacts
title_fullStr Effect of Temperature Distribution in Ultrasonically Welded Joints of Copper Wire and Sheet Used for Electrical Contacts
title_full_unstemmed Effect of Temperature Distribution in Ultrasonically Welded Joints of Copper Wire and Sheet Used for Electrical Contacts
title_short Effect of Temperature Distribution in Ultrasonically Welded Joints of Copper Wire and Sheet Used for Electrical Contacts
title_sort effect of temperature distribution in ultrasonically welded joints of copper wire and sheet used for electrical contacts
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6025159/
https://www.ncbi.nlm.nih.gov/pubmed/29904006
http://dx.doi.org/10.3390/ma11061010
work_keys_str_mv AT pradeepkumarjeyaraj effectoftemperaturedistributioninultrasonicallyweldedjointsofcopperwireandsheetusedforelectricalcontacts