Cargando…
Adaptability of Closed Loop During Labor, Delivery, and Postpartum: A Secondary Analysis of Data from Two Randomized Crossover Trials in Type 1 Diabetes Pregnancy
Tight glucose control during labor and delivery is recommended for pregnant women with type 1 diabetes. This can be challenging to achieve using the current treatment modalities. The automated nature of closed loop and its ability to adapt to real-time glucose levels make it well suited for use duri...
Autores principales: | Stewart, Zoe A., Yamamoto, Jennifer M., Wilinska, Malgorzata E., Hartnell, Sarah, Farrington, Conor, Hovorka, Roman, Murphy, Helen R. |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Mary Ann Liebert, Inc.
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6025695/ https://www.ncbi.nlm.nih.gov/pubmed/29958022 http://dx.doi.org/10.1089/dia.2018.0060 |
Ejemplares similares
-
Fully automated closed-loop insulin delivery in adults with type 2 diabetes: an open-label, single-center, randomized crossover trial
por: Daly, Aideen B., et al.
Publicado: (2023) -
Who Should Access Closed-Loop Technology? A Qualitative Study of Clinician Attitudes in England
por: Farrington, Conor, et al.
Publicado: (2020) -
Fully automated closed-loop glucose control compared with standard insulin therapy in adults with type 2 diabetes requiring dialysis: an open-label, randomized crossover trial
por: Boughton, Charlotte K., et al.
Publicado: (2021) -
Publisher Correction: Fully automated closed-loop glucose control compared with standard insulin therapy in adults with type 2 diabetes requiring dialysis: an open-label, randomized crossover trial
por: Boughton, Charlotte K., et al.
Publicado: (2021) -
Modelling endogenous insulin concentration in type 2 diabetes during closed-loop insulin delivery
por: Ruan, Yue, et al.
Publicado: (2015)