Cargando…

Correction of center of rotation and projection angle in synchrotron X-ray computed tomography

An error in tomographic reconstruction parameters can result considerable artifacts in the reconstructed image, particularly in micro-computed tomography and nano-computed tomography. This study involved designing an automatic method for efficiently correcting errors resulting from incorrectly deter...

Descripción completa

Detalles Bibliográficos
Autores principales: Cheng, Chang-Chieh, Ching, Yu-Tai, Ko, Pai-Hung, Hwu, Yeukuang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6026166/
https://www.ncbi.nlm.nih.gov/pubmed/29959398
http://dx.doi.org/10.1038/s41598-018-28149-8
_version_ 1783336398897545216
author Cheng, Chang-Chieh
Ching, Yu-Tai
Ko, Pai-Hung
Hwu, Yeukuang
author_facet Cheng, Chang-Chieh
Ching, Yu-Tai
Ko, Pai-Hung
Hwu, Yeukuang
author_sort Cheng, Chang-Chieh
collection PubMed
description An error in tomographic reconstruction parameters can result considerable artifacts in the reconstructed image, particularly in micro-computed tomography and nano-computed tomography. This study involved designing an automatic method for efficiently correcting errors resulting from incorrectly determined rotational axes and projection angles. In this method, errors are corrected by minimizing the “total variation” of a reconstructed image, and minimization is accomplished by using the gradient descent method. Compared with two previous methods, the proposed method achieved the best reconstruction results.
format Online
Article
Text
id pubmed-6026166
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-60261662018-07-09 Correction of center of rotation and projection angle in synchrotron X-ray computed tomography Cheng, Chang-Chieh Ching, Yu-Tai Ko, Pai-Hung Hwu, Yeukuang Sci Rep Article An error in tomographic reconstruction parameters can result considerable artifacts in the reconstructed image, particularly in micro-computed tomography and nano-computed tomography. This study involved designing an automatic method for efficiently correcting errors resulting from incorrectly determined rotational axes and projection angles. In this method, errors are corrected by minimizing the “total variation” of a reconstructed image, and minimization is accomplished by using the gradient descent method. Compared with two previous methods, the proposed method achieved the best reconstruction results. Nature Publishing Group UK 2018-06-29 /pmc/articles/PMC6026166/ /pubmed/29959398 http://dx.doi.org/10.1038/s41598-018-28149-8 Text en © The Author(s) 2018 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Cheng, Chang-Chieh
Ching, Yu-Tai
Ko, Pai-Hung
Hwu, Yeukuang
Correction of center of rotation and projection angle in synchrotron X-ray computed tomography
title Correction of center of rotation and projection angle in synchrotron X-ray computed tomography
title_full Correction of center of rotation and projection angle in synchrotron X-ray computed tomography
title_fullStr Correction of center of rotation and projection angle in synchrotron X-ray computed tomography
title_full_unstemmed Correction of center of rotation and projection angle in synchrotron X-ray computed tomography
title_short Correction of center of rotation and projection angle in synchrotron X-ray computed tomography
title_sort correction of center of rotation and projection angle in synchrotron x-ray computed tomography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6026166/
https://www.ncbi.nlm.nih.gov/pubmed/29959398
http://dx.doi.org/10.1038/s41598-018-28149-8
work_keys_str_mv AT chengchangchieh correctionofcenterofrotationandprojectionangleinsynchrotronxraycomputedtomography
AT chingyutai correctionofcenterofrotationandprojectionangleinsynchrotronxraycomputedtomography
AT kopaihung correctionofcenterofrotationandprojectionangleinsynchrotronxraycomputedtomography
AT hwuyeukuang correctionofcenterofrotationandprojectionangleinsynchrotronxraycomputedtomography