Cargando…
Interobserver and intraobserver reliability of different methods of examination for presence of palmaris longus and examination of fifth superficial flexor function
The palmaris longus is harvested as a tendon graft in various surgical procedures. Several tests are used to assess the presence of palmaris longus tendon. In the present study, we attempted to assess the interobserver and intraobserver reliability of five of the most famous methods and also the exa...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Association of Anatomists
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6026822/ https://www.ncbi.nlm.nih.gov/pubmed/29984051 http://dx.doi.org/10.5115/acb.2018.51.2.79 |
_version_ | 1783336507760705536 |
---|---|
author | Sadeghifar, Amirreza Kahani, Ali Krbalei Saied, Alireza Rasayi, Elham |
author_facet | Sadeghifar, Amirreza Kahani, Ali Krbalei Saied, Alireza Rasayi, Elham |
author_sort | Sadeghifar, Amirreza |
collection | PubMed |
description | The palmaris longus is harvested as a tendon graft in various surgical procedures. Several tests are used to assess the presence of palmaris longus tendon. In the present study, we attempted to assess the interobserver and intraobserver reliability of five of the most famous methods and also the examination of fifth superficial flexor function. Two observers, who had been trained on the tests and had practiced them, examined 105 volunteers on two separate occasions and in 1-month interval the results were recorded. The reliability of each method was assessed with Kappa measurement. Kappa ranged from 0.541 (moderate reliability) to 0.813 (almost complete agreement) for palmaris. The highest interobserver and intraobserver reliability and also the best agreement with other tests were of Schaeffer. The lowest kappa was for Thompson and the others have good to excellent reliability. Kappa for interobserver and intraobserver reliability for the fifth flexor were 0.415 and 0.500 (moderate reliability), respectively. The tests that were assessed have good reliability except for Thompson that has a moderate one. It seems that the standard test (Schaeffer) is the best method for the assessment of the absence or presence of palmaris longus. The method used for the evaluation of fifth superficial flexor variations assessment has a moderate interobserver and intraobserver reliability. |
format | Online Article Text |
id | pubmed-6026822 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Korean Association of Anatomists |
record_format | MEDLINE/PubMed |
spelling | pubmed-60268222018-07-07 Interobserver and intraobserver reliability of different methods of examination for presence of palmaris longus and examination of fifth superficial flexor function Sadeghifar, Amirreza Kahani, Ali Krbalei Saied, Alireza Rasayi, Elham Anat Cell Biol Original Article The palmaris longus is harvested as a tendon graft in various surgical procedures. Several tests are used to assess the presence of palmaris longus tendon. In the present study, we attempted to assess the interobserver and intraobserver reliability of five of the most famous methods and also the examination of fifth superficial flexor function. Two observers, who had been trained on the tests and had practiced them, examined 105 volunteers on two separate occasions and in 1-month interval the results were recorded. The reliability of each method was assessed with Kappa measurement. Kappa ranged from 0.541 (moderate reliability) to 0.813 (almost complete agreement) for palmaris. The highest interobserver and intraobserver reliability and also the best agreement with other tests were of Schaeffer. The lowest kappa was for Thompson and the others have good to excellent reliability. Kappa for interobserver and intraobserver reliability for the fifth flexor were 0.415 and 0.500 (moderate reliability), respectively. The tests that were assessed have good reliability except for Thompson that has a moderate one. It seems that the standard test (Schaeffer) is the best method for the assessment of the absence or presence of palmaris longus. The method used for the evaluation of fifth superficial flexor variations assessment has a moderate interobserver and intraobserver reliability. Korean Association of Anatomists 2018-06 2018-06-27 /pmc/articles/PMC6026822/ /pubmed/29984051 http://dx.doi.org/10.5115/acb.2018.51.2.79 Text en Copyright © 2018. Anatomy & Cell Biology http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Sadeghifar, Amirreza Kahani, Ali Krbalei Saied, Alireza Rasayi, Elham Interobserver and intraobserver reliability of different methods of examination for presence of palmaris longus and examination of fifth superficial flexor function |
title | Interobserver and intraobserver reliability of different methods of examination for presence of palmaris longus and examination of fifth superficial flexor function |
title_full | Interobserver and intraobserver reliability of different methods of examination for presence of palmaris longus and examination of fifth superficial flexor function |
title_fullStr | Interobserver and intraobserver reliability of different methods of examination for presence of palmaris longus and examination of fifth superficial flexor function |
title_full_unstemmed | Interobserver and intraobserver reliability of different methods of examination for presence of palmaris longus and examination of fifth superficial flexor function |
title_short | Interobserver and intraobserver reliability of different methods of examination for presence of palmaris longus and examination of fifth superficial flexor function |
title_sort | interobserver and intraobserver reliability of different methods of examination for presence of palmaris longus and examination of fifth superficial flexor function |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6026822/ https://www.ncbi.nlm.nih.gov/pubmed/29984051 http://dx.doi.org/10.5115/acb.2018.51.2.79 |
work_keys_str_mv | AT sadeghifaramirreza interobserverandintraobserverreliabilityofdifferentmethodsofexaminationforpresenceofpalmarislongusandexaminationoffifthsuperficialflexorfunction AT kahanialikrbalei interobserverandintraobserverreliabilityofdifferentmethodsofexaminationforpresenceofpalmarislongusandexaminationoffifthsuperficialflexorfunction AT saiedalireza interobserverandintraobserverreliabilityofdifferentmethodsofexaminationforpresenceofpalmarislongusandexaminationoffifthsuperficialflexorfunction AT rasayielham interobserverandintraobserverreliabilityofdifferentmethodsofexaminationforpresenceofpalmarislongusandexaminationoffifthsuperficialflexorfunction |