Cargando…

Short-interval intracortical inhibition: Comparison between conventional and threshold-tracking techniques

BACKGROUND: Short-interval intracortical inhibition (SICI) is conventionally measured as the relative amplitude reduction of motor evoked potentials (MEPs) by subthreshold conditioning stimuli. In threshold-tracking SICI (T-SICI), stimulus intensity is instead adjusted repeatedly to maintain a const...

Descripción completa

Detalles Bibliográficos
Autores principales: Samusyte, Gintaute, Bostock, Hugh, Rothwell, John, Koltzenburg, Martin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6028741/
https://www.ncbi.nlm.nih.gov/pubmed/29573989
http://dx.doi.org/10.1016/j.brs.2018.03.002
Descripción
Sumario:BACKGROUND: Short-interval intracortical inhibition (SICI) is conventionally measured as the relative amplitude reduction of motor evoked potentials (MEPs) by subthreshold conditioning stimuli. In threshold-tracking SICI (T-SICI), stimulus intensity is instead adjusted repeatedly to maintain a constant MEP and inhibition is measured as the relative threshold increase. T-SICI is emerging as a useful diagnostic test, but its relationship to conventional amplitude SICI (A-SICI) is unclear. OBJECTIVE: To compare T-SICI and its reliability with conventional A-SICI measurements. METHODS: In twelve healthy volunteers (6 men, median age 30 years), conventional and T-SICI were recorded at conditioning stimuli (CS) of 50–80% resting motor threshold (RMT) and interstimulus interval of 2.5 ms. Measurements were repeated on the same day and at least a week later by a single operator. RESULTS: Across the CS range, mean group T-SICI showed a strong linear relationship to the mean group values measured by conventional technique (y = 29.7–0.3x, R(2) = 0.99), but there was considerable interindividual variability. At CS 60–80% RMT, T-SICI had excellent intraday (intraclass correlation coefficient, ICC, 0.81–0.92) and adequate-to-excellent interday (ICC 0.61–0.88) reproducibility. Conventional SICI took longer to complete (median of 5.8 vs 3.8 min, p < 0.001) and tended to have poorer reproducibility (ICC 0.17–0.42 intraday, 0.37–0.51 interday). With T-SICI, smaller sample sizes were calculated for equally powered interventional studies. CONCLUSION: The close relationship between conventional and T-SICI suggests that both techniques reflect similar cortical inhibitory mechanisms. Threshold-tracking measurements of SICI may be able to improve reproducibility, to shorten acquisition time and to reduce sample sizes for interventional studies compared with the conventional technique.