Cargando…
Proton versus photon deep inspiration breath hold technique in patients with hodgkin lymphoma and mediastinal radiation: A Planning Comparison Of Deep Inspiration Breath Hold Intensity Modulation Radiotherapy And Intensity Modulated Proton Therapy
BACKGROUND: The benefits of proton therapy in the treatment of patients with Hodgkin lymphoma (HL) are controversially discussed. Therefore we compared intensitiy modulated proton therapy (IMPT) with intensity modulated radiotherapy (IMRT), in the form of volumetric modulated arc therapy (VMAT) in p...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6029162/ https://www.ncbi.nlm.nih.gov/pubmed/29970105 http://dx.doi.org/10.1186/s13014-018-1066-2 |
_version_ | 1783336907768332288 |
---|---|
author | Baues, Christian Marnitz, Simone Engert, Andreas Baus, Wolfgang Jablonska, Karolina Fogliata, Antonella Vásquez-Torres, Andrés Scorsetti, Marta Cozzi, Luca |
author_facet | Baues, Christian Marnitz, Simone Engert, Andreas Baus, Wolfgang Jablonska, Karolina Fogliata, Antonella Vásquez-Torres, Andrés Scorsetti, Marta Cozzi, Luca |
author_sort | Baues, Christian |
collection | PubMed |
description | BACKGROUND: The benefits of proton therapy in the treatment of patients with Hodgkin lymphoma (HL) are controversially discussed. Therefore we compared intensitiy modulated proton therapy (IMPT) with intensity modulated radiotherapy (IMRT), in the form of volumetric modulated arc therapy (VMAT) in patients with Hodgkin lymphoma (HL), through a comparative treatment planning study. METHODS: Radiation plans for 21 patients with Hodgkin Lymphoma (HL) were computed for IMPT and deep inspiration breath hold (DIBH) VMAT. Plans were optimized and computed assuming deep inspiration breath holding conditions. Dosimetric comparison on standard metrics from dose volume histograms was performed to appraise the relative merits of the two techniques, while proton plan robustness was assessed by re-computing the dose distribution of each plan by varying the Hounsfield Units to stopping power calibration by applying a ± 3 and 4% error. RESULTS: DIBH-VMAT and IMPT both provided excellent coverage, conformity and heterogeneity of the clinical target volume (CTV) and planning target volume (PTV). IMPT reduced mean doses to the breasts, lungs, heart and normal tissue by 38–83%. IMPT significantly reduced mean doses to the heart to < 5 Gy despite bulky mediastinal disease and decreased breast doses in female patients to < 1 Gy. Despite the simulated 3 and 4% miscalibration errors, no remarkable or measurable impact was observed on the organs at risk (OARs). CONCLUSIONS: This is the first comparison between DIBH-VMAT and IMPT in HL treatment. We could demonstrate statistically significant decreases in all dose/volume metrics of the OARs. Regardless of the planning paradigm used, range uncertainties can substantially under dose the PTV, while perhaps not leading to clinically significant deterioration of CTV coverage. With the geometry applied no impact was observed for OARs, suggesting IMPT as a superior technique for potentially reducing future health risks for HL patients. |
format | Online Article Text |
id | pubmed-6029162 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-60291622018-07-09 Proton versus photon deep inspiration breath hold technique in patients with hodgkin lymphoma and mediastinal radiation: A Planning Comparison Of Deep Inspiration Breath Hold Intensity Modulation Radiotherapy And Intensity Modulated Proton Therapy Baues, Christian Marnitz, Simone Engert, Andreas Baus, Wolfgang Jablonska, Karolina Fogliata, Antonella Vásquez-Torres, Andrés Scorsetti, Marta Cozzi, Luca Radiat Oncol Research BACKGROUND: The benefits of proton therapy in the treatment of patients with Hodgkin lymphoma (HL) are controversially discussed. Therefore we compared intensitiy modulated proton therapy (IMPT) with intensity modulated radiotherapy (IMRT), in the form of volumetric modulated arc therapy (VMAT) in patients with Hodgkin lymphoma (HL), through a comparative treatment planning study. METHODS: Radiation plans for 21 patients with Hodgkin Lymphoma (HL) were computed for IMPT and deep inspiration breath hold (DIBH) VMAT. Plans were optimized and computed assuming deep inspiration breath holding conditions. Dosimetric comparison on standard metrics from dose volume histograms was performed to appraise the relative merits of the two techniques, while proton plan robustness was assessed by re-computing the dose distribution of each plan by varying the Hounsfield Units to stopping power calibration by applying a ± 3 and 4% error. RESULTS: DIBH-VMAT and IMPT both provided excellent coverage, conformity and heterogeneity of the clinical target volume (CTV) and planning target volume (PTV). IMPT reduced mean doses to the breasts, lungs, heart and normal tissue by 38–83%. IMPT significantly reduced mean doses to the heart to < 5 Gy despite bulky mediastinal disease and decreased breast doses in female patients to < 1 Gy. Despite the simulated 3 and 4% miscalibration errors, no remarkable or measurable impact was observed on the organs at risk (OARs). CONCLUSIONS: This is the first comparison between DIBH-VMAT and IMPT in HL treatment. We could demonstrate statistically significant decreases in all dose/volume metrics of the OARs. Regardless of the planning paradigm used, range uncertainties can substantially under dose the PTV, while perhaps not leading to clinically significant deterioration of CTV coverage. With the geometry applied no impact was observed for OARs, suggesting IMPT as a superior technique for potentially reducing future health risks for HL patients. BioMed Central 2018-07-03 /pmc/articles/PMC6029162/ /pubmed/29970105 http://dx.doi.org/10.1186/s13014-018-1066-2 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Baues, Christian Marnitz, Simone Engert, Andreas Baus, Wolfgang Jablonska, Karolina Fogliata, Antonella Vásquez-Torres, Andrés Scorsetti, Marta Cozzi, Luca Proton versus photon deep inspiration breath hold technique in patients with hodgkin lymphoma and mediastinal radiation: A Planning Comparison Of Deep Inspiration Breath Hold Intensity Modulation Radiotherapy And Intensity Modulated Proton Therapy |
title | Proton versus photon deep inspiration breath hold technique in patients with hodgkin lymphoma and mediastinal radiation: A Planning Comparison Of Deep Inspiration Breath Hold Intensity Modulation Radiotherapy And Intensity Modulated Proton Therapy |
title_full | Proton versus photon deep inspiration breath hold technique in patients with hodgkin lymphoma and mediastinal radiation: A Planning Comparison Of Deep Inspiration Breath Hold Intensity Modulation Radiotherapy And Intensity Modulated Proton Therapy |
title_fullStr | Proton versus photon deep inspiration breath hold technique in patients with hodgkin lymphoma and mediastinal radiation: A Planning Comparison Of Deep Inspiration Breath Hold Intensity Modulation Radiotherapy And Intensity Modulated Proton Therapy |
title_full_unstemmed | Proton versus photon deep inspiration breath hold technique in patients with hodgkin lymphoma and mediastinal radiation: A Planning Comparison Of Deep Inspiration Breath Hold Intensity Modulation Radiotherapy And Intensity Modulated Proton Therapy |
title_short | Proton versus photon deep inspiration breath hold technique in patients with hodgkin lymphoma and mediastinal radiation: A Planning Comparison Of Deep Inspiration Breath Hold Intensity Modulation Radiotherapy And Intensity Modulated Proton Therapy |
title_sort | proton versus photon deep inspiration breath hold technique in patients with hodgkin lymphoma and mediastinal radiation: a planning comparison of deep inspiration breath hold intensity modulation radiotherapy and intensity modulated proton therapy |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6029162/ https://www.ncbi.nlm.nih.gov/pubmed/29970105 http://dx.doi.org/10.1186/s13014-018-1066-2 |
work_keys_str_mv | AT baueschristian protonversusphotondeepinspirationbreathholdtechniqueinpatientswithhodgkinlymphomaandmediastinalradiationaplanningcomparisonofdeepinspirationbreathholdintensitymodulationradiotherapyandintensitymodulatedprotontherapy AT marnitzsimone protonversusphotondeepinspirationbreathholdtechniqueinpatientswithhodgkinlymphomaandmediastinalradiationaplanningcomparisonofdeepinspirationbreathholdintensitymodulationradiotherapyandintensitymodulatedprotontherapy AT engertandreas protonversusphotondeepinspirationbreathholdtechniqueinpatientswithhodgkinlymphomaandmediastinalradiationaplanningcomparisonofdeepinspirationbreathholdintensitymodulationradiotherapyandintensitymodulatedprotontherapy AT bauswolfgang protonversusphotondeepinspirationbreathholdtechniqueinpatientswithhodgkinlymphomaandmediastinalradiationaplanningcomparisonofdeepinspirationbreathholdintensitymodulationradiotherapyandintensitymodulatedprotontherapy AT jablonskakarolina protonversusphotondeepinspirationbreathholdtechniqueinpatientswithhodgkinlymphomaandmediastinalradiationaplanningcomparisonofdeepinspirationbreathholdintensitymodulationradiotherapyandintensitymodulatedprotontherapy AT fogliataantonella protonversusphotondeepinspirationbreathholdtechniqueinpatientswithhodgkinlymphomaandmediastinalradiationaplanningcomparisonofdeepinspirationbreathholdintensitymodulationradiotherapyandintensitymodulatedprotontherapy AT vasqueztorresandres protonversusphotondeepinspirationbreathholdtechniqueinpatientswithhodgkinlymphomaandmediastinalradiationaplanningcomparisonofdeepinspirationbreathholdintensitymodulationradiotherapyandintensitymodulatedprotontherapy AT scorsettimarta protonversusphotondeepinspirationbreathholdtechniqueinpatientswithhodgkinlymphomaandmediastinalradiationaplanningcomparisonofdeepinspirationbreathholdintensitymodulationradiotherapyandintensitymodulatedprotontherapy AT cozziluca protonversusphotondeepinspirationbreathholdtechniqueinpatientswithhodgkinlymphomaandmediastinalradiationaplanningcomparisonofdeepinspirationbreathholdintensitymodulationradiotherapyandintensitymodulatedprotontherapy |